TY - JOUR N2 - The results presented in this article are part of the research on fatigue life of various foundry alloys carried out in recent years in the Lukasiewicz Research Network – Institute of Precision Mechanics and AGH University of Science and Technology, Faculty of Foundry Engineering. The article discusses the test results obtained for the EN-GJS-600-3 cast iron in an original modified low-cycle fatigue test (MLCF), which seems to be a beneficial research tool allowing its users to evaluate the mechanical properties of materials with microstructural heterogeneities under both static and dynamic loads. For a comprehensive analysis of the mechanical behaviour with a focus on fatigue life of alloys, an original modified low cycle fatigue method (MLCF) adapted to the actually available test machine was used. The results of metallographic examinations carried out by light microscopy were also presented. From the analysis of the results of the conducted mechanical tests and structural examinations it follows that the MLCF method is fully applicable in a quick and economically justified assessment of the quality of ductile iron after normalizing treatment. L1 - http://czasopisma.pan.pl/Content/113140/PDF/AFE%204_2019_04.pdf L2 - http://czasopisma.pan.pl/Content/113140 PY - 2019 IS - No 4 EP - 32 DO - 10.24425/afe.2019.129625 KW - Iron KW - Mechanical properties KW - Microstructure A1 - Maj, M. A1 - Pietrzak, K. A1 - Klasik, A. PB - The Katowice Branch of the Polish Academy of Sciences VL - vol. 19 DA - 2019.09.24 T1 - Mechanical Characteristics of Ductile Iron Determined in an Original Modified Low Cycle test SP - 27 UR - http://czasopisma.pan.pl/dlibra/publication/edition/113140 T2 - Archives of Foundry Engineering ER -