Abstract

The article presents the results of laboratory measurements of Ud breakdown voltages in a high-voltage vacuum insulating system for different pressures, contact gaps, type of electrode contacts and type of residual gas inside the discharge chamber. First of all, the electrical strength of the discharge chamber with a contact system terminated with contact pads made of W 70Cu 30 and Cu 75Cr 25 material was compared for selected values of contact gaps. It was found that below a pressure of p = 3.0 x 10 -1 Pa the electrical strength reaches an approximately constant value for each of the set contact gaps d. Analytical relationships were determined to calculate this value for each of the contact pads used. Above a pressure of p = 3.0 x 10 -1 Pa, the measured values of Ud breakdown voltages decrease sharply. The values of breakdown voltages in the discharge chamber with residual gases in the form of air, argon, neon and helium were also determined for selected values of contact gaps d. Depending on the residual gases used, significant differences were noted in the values of pressure p at which the loss of insulating properties in the discharge chamber occurred. These values were 3.3 x 10 -1 Pa for argon, 4.1 x 10 -1 Pa for air, 6.4 x 10 -1 Pa for neon, and 2.55 x 10 0 Pa for helium, respectively.
Go to article

Authors and Affiliations

Michał Lech
1
ORCID: ORCID
Paweł Węgierek
1
ORCID: ORCID

  1. Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, Nadbystrzycka 38A str., 20-618 Lublin, Poland
Download PDF Download RIS Download Bibtex

Abstract

In this paper, the dynamic behaviour of the tensegrity domes is explored. The consideration includes all cable structures called Geiger domes, i.e., two cases of configurations (with a closed and open upper section) and two variants of the nature of a dome (regular and modified) are taken into account. Particularly, the impact of the number of girders on the natural frequencies is analysed. A geometrically quasi-linear model is used, implemented in an original program written in the Mathematica environment. The results confirmthat the number of girders affects the number of infinitesimal mechanisms. However, the dynamic behaviour does not depend on the number of mechanisms. The most important is the nature of a dome and the type of load-bearing girder. Especially, the behaviour of Geiger domes with a closed upper section is specific. In this case, not only the frequencies corresponding to the infinitesimal mechanisms depend on the prestress. There are additional frequencies that depend on prestress. The number of them, and the sensitivity on the initial prestress changes, depends on the number of girders. Generally, for the same number of girders, the natural frequencies of regular domes are higher than for the modified ones.
Go to article