Abstract

This paper established a radio-frequency electrode model and human head model used in RF cosmetic instruments. The distribution of electric field strength, a specific absorption rate (SAR), and temperature distribution in the human brain at 1 MHz and 6 MHz were studied and the results compared with the International Commission on Nonionizing Radiation Protection (ICNIRP) guidelines. The results showed that under those two frequencies the maximum value of electric field strength in the human brain was 1.52 V/m and it was about 5.4% of the ICNIRP basic restrictions, the maximum SAR in human brain was about 2:21 ? 10??3 W/kg, which was far less than 2 W/kg of ICNIRP basic restrictions, the maximum temperature of the human brainwas 37:6? located in thewounded skin, which was the same as the normal temperature 37?. Since all the results were within the ICNIRP basic restrictions, the electromagnetic exposure generated by the RF cosmetic electrode will not pose a threat to the human health.
Go to article

Bibliography

[1] Bidi M., Biological risk assessment of high-voltage transmission lines on worker’s health of electric society, Archives of Electrical Engineering, vol. 69, no. 1, pp. 57–68 (2020).
[2] Deltuva R., Lukocius R., Electric and magnetic field of different transpositions of overhead power line, Archives of Electrical Engineering, vol. 66, no. 3, pp. 595–605 (2017).
[3] Alam M., Levy R., Pajvani U., Ramierez A., Guitart J., Veen H., Gladstone B., Safety of radiofrequency treatment over human skin previously injected with medium-term injectable soft-tissue augmentation materials: a controlled pilot trial, Lasers in Surgery and Medicine, vol. 39, no. 5, pp. 468–468 (2007).
[4] Suh D.H., Byun J.E., Lee J.S., Song Y.K., Kim S.H., Clinical efficacy and safety evaluation of a novel fractional unipolar radiofrequency device on facial tightening: A preliminary report, Journal of Cosmetic Dermatology, vol. 16, no. 2, pp. 199–204 (2017).
[5] Lee S.H., Lee D.H., Won C.H., Chang H.W., Kwon H.H., Kim K.H., Chung J.H., Fractional rejuvenation using a novel bipolar radiofrequency system in Asian skin, Dermatol Surgery, vol. 37, no. 11, pp. 1611–1619 (2011).
[6] International Commission on Non-ionizing Radiation Protection Guidelines for limiting exposure to time-varying electric and magnetic fields (up to 300GHz), Health Physics, vol. 74, no. 4, pp. 494–522 (1998).
[7] Alhalabi S.M., Agha O.Q., Hantash B.M., Nonablative radiofrequency for skin rejuvenation: a review of the literature, Expert Review of Dermatology, vol. 7, no. 7, pp. 589–599 (2012).
[8] Sadick N., Tissue tightening technologies: Fact or fiction, Aesthetic Surgery Journal, vol. 28, no. 2, pp. 180–188 (2008).
[9] Nelson A., Beynet D., Lask G., A novel non-invasive radiofrequency dermal heating device for skin tightening of the face and neck, Journal of Cosmetic and Laser Therapy, vol. 17, no. 6, pp. 1–6 (2015).
[10] Friedman J., Gilead L., The Use of Hybrid Radiofrequency Device for the Treatment of Rhytids and Lax Skin, Dermatologic Surgery, vol. 33, no. 5, pp. 547–551 (2007).
[11] Brightman L., Goldman MP., Taub A.F., Sublative Rejuvenation: Experience with a New Fractional Radiofrequency System for Skin Rejuvenation and Repair, Journal of Drugs in Dermatology, vol. 8, no. 11, pp. 9–13 (2009).
[12] Hsu T.S., Kaminer M.S., The use of nonablative radiofrequency technology to tighten the lower face and neck, Seminars in Cutaneous Medicine and Surgery, vol. 22, no. 2, pp. 1–123 (2003).
[13] Rush S., Driscoll D.A., EEG electrode sensitivity–an application of reciprocity, IEEE Transactions on Biomedical Engineering, vol. 16, no. 1, pp. 15–22 (1968).
[14] Huclova S., Baumann D., Talary M., Frohlich J., Sensitivity and specificity analysis of fringing-field dielectric spectroscopy applied to a multi-layer system modelling the human skin, Physics in Medicine and Biology, vol. 56, no. 24, pp. 7777–7793 (2011).
[15] Gabriel C., Bentall R., Grant E.H., Comparison of the dielectric properties of normal and wounded human skin material, Bioelectromagnetics, vol. 8, no. 1, pp. 23–27 (1987).
[16] Huclova S., Erni D., Frohlich J., Modelling and validation of dielectric properties of human skin in the MHz region focusing on skin layer morphology and material composition, Journal of Physics D Applied Physics, vol. 45, no. 45 (2012), DOI: 10.1088/0022-3727/45/2/025301.
[17] Cole K., Cole R., Dispersion and absorption in dielectrics: I. Alternating current characteristics, Journal of Chemical Physics, vol. 9, no. 4, pp. 341–351 (1941).
[18] http://www.itis.ethz.ch/database.pl, accessed January 2020.
[19] http://cn.comsol.com/pl, accessed January 2020.
[20] Rush S., Driscoll D.A., Current distribution in the brain from surface electrodes, Anesthesia and Analgesia, vol. 47, no. 6, pp. 717–723 (1968).
[21] Tamnes K., Ostby Y., Fjell A.M., Westlye L.T., Due P., Walhovd K., Brain maturation in adolescence and young adulthood: regional age-related changes in cortical thickness and white matter volume and microstructure, Cerebral Cortex, vol. 20, no. 3, pp. 534–548 (2010).
[22] Gabriel S., Lau W., Gabriel C., The dielectric properties of biological tissues: III parametric models for the dielectric spectrum of tissues, Physics in Medicine and Biology, vol. 41, no. 11, pp. 2271–2293 (1996).
[23] Hruza G., Taub F., Collier S., Mulholland R., Skin rejuvenation and wrinkle reduction using a fractional radiofrequency system, Journal of Drugs in Dermatology, vol. 8, no. 3, pp. 259–265 (2009).









Go to article

Authors and Affiliations

Xinzhe Qi
1
Mai Lu
1
ORCID: ORCID

  1. Key Laboratory of Opt-Electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University, Lanzhou, 730070, Gansu Province, P.R. China
Download PDF Download RIS Download Bibtex

Abstract

In this work we discussed the safety of the electric field environment in the No.3 carriage where the pantograph is located. DSA380 pantograph, CRH5 EMU carriage and passengers’ models were established to study the electric field exposure of passengers at different positions. The results showed that Emax in the carriage without passengers is 1.173 x 10 6 mV/m. Then we set the passengers’ positions according to the electric field distribution in the carriage without passengers and obtained that Emax in the carriage with passengers is 3.195 x 10 6 mV/m. It can be seen that the maximum induced electric field intensity of passengers at different positions appears on the soles of shoes, the maximum value is 3.028 x 105 mV/m, the maximum induced current density occurs at the ankle, its maximum value is 3.476 x 10 -5 A/m 2. It can be concluded that the maximum induced electric field intensity of passenger’s head appears in the cerebrospinal fluid area, with a maximum value of 202.817 mV/m, and the maximum induced electric field intensity of passenger’s head at the door is larger than that in the middle of the carriage. The maximum values of the induced electric field intensity in all tissues of passengers are much smaller than the basic limits of electromagnetic exposure to the public set by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). This study indicated that the pantograph has little influence on the electric field environment in the carriage under working state, and will not cause any health hazard to the passengers in this working frequency electric field environment.
Go to article

Authors and Affiliations

Rui Tian
1
Jia-qi Zhang
1
Mai Lu
1
ORCID: ORCID

  1. Key Laboratory of Opto-Electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University, Gansu Province, China
Download PDF Download RIS Download Bibtex

Abstract

The objective of this work is to evaluate the safety of adult and child passengers exposed to a radio frequency (RF) source, i.e., a leaky coaxial cable (LCX) on the subway platform. An adult model, a child model, and an LCX model have been numerically designed in COMSOL Multiphysics software. The distributions of the induced electric field (E-field), specific absorption rate (SAR), magnetic field ( H-field) and the head temperature increase in adult and child passenger models were calculated at 900 MHz. The induced fields in the passengers were compared with that without screen doors. The results show that the E-field, SAR and H-field in the whole body of the child are 2.00 × 10 -2 V/m, 1.07 × 10 -7 W/kg, and 2.94 × 10 -4 A/m, respectively. The E-field, SAR and H-field in the central nervous system of the child are 1.00e × 10 -2 V/m, 2.44 × 10 -8 W/kg, and 2.41 × 10 -4 A/m, respectively. The maximum values of the E-field, SAR and H-field in the adult passenger are 1.49–2.34 times higher than those of the child. The E-field, SAR, and H-field in the passenger models without a screen door are larger than those with a screen door. The screen door has a partial shielding effect on the RF electromagnetic field. The values of the maximum temperature that increases in adult and child head tissue are 0.2114 and 0.2111℃ after waiting 6 minutes exposure, respectively. All calculated results are well below the International Commission on Non-Ionizing Radiation Protection (ICNIRP) limits for general public exposure, indicating that RF electromagnetic exposure caused by the LCX on the subway platform is not a threat to passenger’s health.
Go to article

Bibliography

[1] https://www.163.com/dy/article/H08UC3PI051481OF.html, accessed February 2022.
[2] Verbeek J., Oftedal G., Feychting M., Rongen E., Prioritizing health outcomes when assessing the effects of exposure to radiofrequency electromagnetic fields: A survey among experts, Environment International, vol. 146, no. 1, pp. 1–6 (2020), DOI: 10.1016/j.envint.2020.106300.
[3] Ju H.K., Lee J.K., Kim H.G., Possible Effects of Radiofrequency Electromagnetic Field Exposure on Central Nerve System, Biomolecules and Therapeutics, vol. 27, no. 3, pp. 265–275 (2019), DOI: 10.4062/biomolther.2018.152.
[4] Jiang D.P., Li J.H., Zhang J., Long-term electromagnetic pulse exposure induces Abeta deposition and cognitive dysfunction through oxidative stress and overexpression of APP and BACE1, Brain Research, vol. 1642, no. 1, pp. 10–19 (2016), DOI: 10.1016/j.brainres.2016.02.053.
[5] Hinrikus H., Bachmann M., Lass J., Understanding physical mechanism of low-level microwave radiation effect, International Journal of Radiation Biology, vol. 94, no. 10, pp. 877–882 (2018), DOI: 10.1080/09553002.2018.1478158.
[6] Baan R., Grosse Y., Lauby-Secretan B., El Ghissassi F., Carcinogenicity of radiofrequency electromagnetic fields, Lancet Oncology, vol. 12, no. 7, pp. 624–626 (2011), DOI: 10.1016/S1470-2045(11)70147-4.
[7] Qi X.Z., Lu M., Study on the distribution of SAR and temperature in human brain during radiofrequency cosmetic treatment, Archives of Electrical Engineering, vol. 70, no. 1, pp. 115–127 (2021), DOI: 10.24425/aee.2021.136056.
[8] Tian R., Lu M., Safety assessment of electromagnetic exposure in high-speed train carriage with full passengers, Annals of Work Exposures and Health, vol. 64, no. 8, pp. 838–851 (2020), DOI: 10.1093/annweh/wxaa048.
[9] Gas P., Wyszkowska J., Influence of multi-tine electrode configuration in realistic hepatic RF ablative heating, Archives of Electrical Engineering, vol. 68, no. 3, pp. 521–533 (2019), DOI: 10.24425/aee.2019.129339.
[10] Stankovi V., Jovanovi D., Krsti D., Temperature distribution and Specific Absorption Rate inside a child’s head, International Journal of Heat and Mass Transfer, vol. 104, no. 1, pp. 559–565 (2017), DOI: 10.1016/j.ijheatmasstransfer.2016.08.094.
[11] Peyman A., Rezazadeh A.A., Gabriel C., Changes in the dielectric properties of rat tissue as a function of age at microwave frequencies, Physics in Medicine and Biology, vol. 46, no. 12, pp. 1617–1629 (2001), DOI: 10.1088/0031-9155/55/15/N02.
[12] Peyman A., Gabriel C., Grant E.H., Variation of the dielectric properties of tissues with age: the effect on the values of SAR in children when exposed to walkie-talkie devices, Physics in Medicine and Biology, vol. 54, no. 1, pp. 227–241 (2009), DOI: 10.1088/0031-9155/54/2/004.
[13] Foster K.R., Chou C.K., Are Children More Exposed to Radio Frequency Energy from Mobile Phones Than Adults?, IEEE Access, vol. 2014, no. 2, pp. 1497–1509 (2014), DOI: 10.1109/ACCESS.2014.2380355.
[14] Gandhi O.P., Yes the children are more exposed to radiofrequency energy from mobile telephones than adults, IEEE Access, vol. 2015, no. 3, pp. 985–988 (2015), DOI: 10.1109/ACCESS.2015.2438782.
[15] Morris R.D., Morgan L.L., Davis D., Children Absorb Higher Doses of Radio Frequency Electromagnetic Radiation from Mobile Phones Than Adults, IEEE Access, vol. 2015, no. 3, pp. 2379–2387 (2015), DOI: 10.1109/ACCESS.2015.2478701.
[16] Stankovi V., Jovanovi D., Krsti D., Markovi V., Cvetkovi N., Temperature distribution and specific absorption rate inside a child’s head, International Journal of Heat and Mass Transfer, vol. 104, no. 1, pp. 559–565 (2017), DOI: 10.1016/j.ijheatmasstransfer.2016.08.094.
[17] ICNIRP, Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz), Health Physics, vol. 118, no. 5, pp. 483–524 (2020), DOI: 10.1097/HP.0000000000001210.
[18] Hardell L., World Health Organization, radiofrequency radiation and health - a hard nut to crack (Review), International Journal of Oncology, vol. 51, no. 2, pp. 405–413 (2017), DOI: 10.3892/ijo.2017.4046.
[19] Tsa B., Db B., Arm B., Biological effects of non-ionizing electromagnetic fields: Two sides of a coin, Progress in Biophysics and Molecular Biology, vol. 141, no. 1, pp. 25–36 (2019), DOI: 10.1016/j.pbiomolbio.2018.07.009.
[20] Ayugi G., Kisolo A., Ireeta T.W., Temporal variation of radiofrequency electromagnetic field exposure from mobile phone base stations in sensitive environments, IOSR Journal of Applied Physics, vol. 9, no. 5, pp. 9–15 (2020), DOI: 10.9790/4861-0905010915.
[21] Carlberg M., Hedendahl L., Koppel T., High ambient radiofrequency radiation in Stockholm city, Sweden, Oncology letters, vol. 17, no. 2, pp. 1777–1783 (2018), DOI: 10.3892/ol.2018.9789.
[22] Hardell L., Koppel T., Carlberg M., Radiofrequency radiation at Stockholm Central Railway Station in Sweden and some medical aspects on public exposure to RF fields, International Journal of Oncology, vol. 49, no. 2, pp. 1315–1324 (2016), DOI: 10.3892/ijo.2016.3657.
[23] Gryz K., Karpowicz J., Radiofrequency electromagnetic radiation exposure inside the metro tube infrastructure in Warszawa, Electromagnetic Biology and Medicine, vol. 34, no. 3, pp. 265–273 (2015), DOI: 10.3109/15368378.2015.1076447.
[24] Zhang B., Zhong Z., He R., Multi-User channels with large-scale antenna arrays in a subway environment: characterization and modeling, IEEE Access, vol. 5, no. 1, pp. 23613–23625 (2017), DOI: 10.1109/ACCESS.2017.2764621.
[25] Yang C.Q., Lu M., Safety evaluation for a high signal operator with electric field exposure induced by contact wires, Archives of Electrical Engineering, vol. 70, no. 2, pp. 431–444 (2021), DOI: 10.24425/aee.2021.136994.
[26] Jalilian H.,Najafi K., Monazzam M.R., Occupational Exposure of Train Drivers to Static and Extremely Low Frequency Magnetic Fields in Tehran Subway, Jundishapur Journal of Health Sciences, vol. 9, no. 4, pp. 1–8 (2017), DOI: 10.5812/jjhs.14329.
[27] Wang J.H., Mei K.K., Design of leaky coaxial cables with periodic slots, Radio Science, vol. 37, no. 5, pp. 1–10 (2002), DOI: 10.1029/2000RS002534.
[28] Standardization Administration of China, Human dimensions of Chinese minors, GB/T 26158-2010 (2011).
[29] Rush S., Current distribution in the brain from surface electrodes, Anesthesia & Analgesia, vol. 47, no. 6, pp. 717–723 (1968).
[30] Gandhi O.P., Lazzi G., Furse C.M., Electromagnetic absorption in the human head and neck for mobile telephones at 835 and 1900 MHz, IEEE Transactions on Microwave Theory and Techniques, vol. 44, no. 10, pp. 1884–1897 (1996), DOI: 10.1109/22.539947.
[31] Gabriel C., Gabriel S., Corthout E., The dielectric properties of biological tissues: I. Literature survey, Phys. Med. Biol., vol. 41, no. 11, pp. 2231–49 (1996).
[32] Wang J., Fujiwara O., Watanabe S., Approximation of aging effect on dielectric tissue properties for SAR assessment of mobile telephones, IEEE Transactions on Electromagnetic Compatibility, vol. 48, no. 2, pp. 408–413 (2006), DOI: 10.1109/TEMC.2006.874085.
[33] Bhargava D., Leeprechanon N., Rattanadecho P., Specific absorption rate and temperature elevation in the human head due to overexposure to mobile phone radiation with different usage patterns, International Journal of Heat and Mass Transfer, vol. 130, no. 3, pp. 1178–1188 (2019), DOI: 10.1016/j.ijheatmasstransfer.2018.11.031.
[34] Pintos V.P., Ovide B.A., Munoz C., EMC measurements in Buenos Aires metro system, IEEE International Symposium on Electromagnetic Compatibility, Turkey, vol. 2003, no. 1, pp. 40–43 (2003), DOI: 10.1109/ICSMC2.2003.1428187.
[35] Lv H.G., Network spectrum measurement technique, Beijing: Tsinghua University Press, pp. 23–36 (2000).
[36] Spiegel R.J., A review of numerical models for predicting the energy deposition and resultant thermal response of humans exposed to electromagnetic fields, IEEE Transactions on Microwave Theory and Techniques, vol. 32, no. 8, pp. 730–746 (1984), DOI: 10.1109/TMTT.1984.1132767.
[37] Pennes H.H., Analysis of tissue and arterial blood temperatures in the resting human forearm, Journal of Applied Physiology, vol. 85, no. 1, pp. 5–34 (1998), DOI: 10.1152/jappl.1998.85.1.5.
[38] Yang D., Converse M.C., Mahvi D.M., Expanding the bioheat equation to include tissue internal water evaporation during heating, IEEE Transactions on Biomedical Engineering, vol. 54, no. 8, pp. 1382–1388 (2007), DOI: 10.1109/TBME.2007.890740.
Go to article

Authors and Affiliations

Jin Li
1
ORCID: ORCID
Mai Lu
1
ORCID: ORCID

  1. Key Laboratory of Opto-Electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University, Gansu Province, China
Download PDF Download RIS Download Bibtex

Abstract

To evaluate the occupational safety of a high signal operator exposed to the electric field induced by contact wires with a frequency of 50 Hz and a voltage of 27.5 kV, this study established a model of a high signal operator working in the vicinity of singleand double-track railways. The electric field distribution in the operator’s body and his head were calculated and analyzed during the operation using the finite element method (FEM). The calculated results were compared with the international standard occupational exposure limits formulated by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and action levels (ALs), exposure limit values (ELVs) in Directive 2013/35/EU (EU Directive). In the case of a single-track railway exposure, the maximum electric field strength in the worker’s body, in the scalp layer, and inside the brain are 227 mV/m, 2.76 kV/m, and 0.14 mV/m, respectively. For a double-track railway exposure, the maximum internal electric field strength of the operator is 310 mV/m, which is 37.85% of the occupational exposure basic restriction limit. The maximum electric field strength in the head layers is 3.42 kV/m, which is 34.2% of the occupational exposure reference level and 34.2% of the low ALs. The maximum electric field strength of the brain is 0.19 mV/m, which is 0.19% of the occupational basic restriction limit and 0.135% of the sensory effects ELVs. Results show that the electric field exposure of the high signal operator to contact wires in single- and double-track railways is lower than the occupational exposure limits provided by the ICNIRP and EU Directive standards and is thus regarded as safe forworkers.
Go to article

Bibliography

[1] Wyszkowska J.W., Jankowska M., Gas P., Electromagnetic fields and neurodegenerative diseases, Przeglad Elektrotechniczny, vol. 95, no. 1, pp. 129–133 (2019).
[2] Mahaki H., Jabarivasal N., Sardarian K., Zamani A., Effects of various densities of 50 Hz electromagnetic field on serum IL-9, IL-10, and TNF-α levels, The International Journal of Occupational and Environmental Medicine, vol. 11, no. 1, pp. 24–32 (2020).
[3] WertheimerN., Leeper E.D., Electrical wiring configurations and childhood cancer, American Journal of Epidemiology, vol. 109, no. 3, pp. 273–284 (1979).
[4] Di G., Dong L., Xie Z., Xu Y., Xiang J., Effects of power frequency electric field exposure on kidney, Ecotoxicology and Environmental Safety, vol. 194, no. 110354, pp. 1–6 (2020).
[5] Syrek P., Skowron M., The impact of overhead lines for employees with stents, IOP Conference Series: Materials Science and Engineering, vol. 200, no. 012013, pp. 1–6 (2017).
[6] Gas P., Miaskowski A., Implant Safety Tool Application to Assist the Assessment of Radio-Frequency Radiation Exposure, Journal of Ecological Engineering, vol. 20, no. 10, pp. 24–33 (2019).
[7] Oancea C.D., Calin F., Golea V., On the Electromagnetic Field in the Surrounding Area of Railway Equipment and Installations, 2019 International Conference on Electromechanical and Energy Systems (SIELMEN), Craiova, Romania, pp.1–5 (2019).
[8] Wen Y.H., Hou W.X., Research on Electromagnetic Compatibility of Chinese High Speed Railway System, Chinese Journal of Electronics, vol. 29, no. 1, pp. 16–21 (2020).
[9] Wrobel Z., The Electromagnetic Compatibility in Researches of Railway Traffic Control Devices, Lecture Notes in Electrical Engineering, vol. 452, pp. 275–287 (2018).
[10] ICNIRP, Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz), Health Physics, vol. 99, no. 6, pp. 818–836 (2010).
[11] 2013/35/EU: Directive of the European Parliament and of the Council of 26 June 2013 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields), Official Journal of the European Union, L 179, pp. 1–21 (2013).
[12] https://timgsa.baidu.com/timg?image&quality=80&size=b9999_10000&sec=1606369465878&di= 311321a9c108936454933bf4a777536f&imgtype=0&src=http%3A%2F%2Fy.zdmimg.com% 2F201711%2F08%2F5a02beb474f797348.jpg_e600.jpg, accessed on December 2020.
[13] http://5b0988e595225.cdn.sohucs.com/images/20181002/5b1720a89c7a456c9cebb2696008ae14.jpeg, accessed on December 2020.
[14] Gas P., Wyszkowska J., Influence of multi-tine electrode configuration in realistic hepatic RF ablative heating, Archives of Electrical Engineering, vol. 68, no. 3, pp. 521–533 (2019).
[15] Stuchly M.A., Dawson T.W., Human body exposure to power lines: relation of induced quantities to external magnetic fields, Health Physics, vol. 83, no. 3, pp. 333–340 (2002).
[16] Lu M., Ueno S., Computational study toward deep transcranial magnetic stimulation using coaxial circular coils, IEEE Transactions on Biomedical Engineering, vol. 62, no. 12, pp. 2911–2919 (2015).
[17] Bidi M., Biological risk assessment of high-voltage transmission lines on worker’s health of electric society, Archives of Electrical Engineering, vol. 69, no. 1, pp. 57–68 (2020).
[18] Bakker J.F., Paulides M.M., Neufeld E., Christ A., Chen X.L., Kuster N., Van Rhoon G.C., Children and adults exposed to low-frequency magnetic fields at the ICNIRP reference levels: Theoretical assessment of the induced electric fields, Physics Medicine Biology, vol. 57, no. 7, pp. 1815–1829 (2012).
[19] Tian R., Lu M., Safety assessment of electromagnetic exposure in high-speed train carriage with full passengers, Annals of Work Exposures and Health, vol. 64, no. 8, pp. 838–851 (2020).
[20] Alvin R.T., Ergonomics diagram – human factors in design, translated by Zhu T., China Architecture and Building Press (1998).
[21] Rush S., Driscoll D.A., Current distribution in the brain from surface electrodes, Anaesthesia and Analgesia, vol. 47, no. 6, pp. 717–723 (1968).
[22] http://niremf.ifac.cnr.it/tissprop/htmlclie/htmlclie.php, accessed on December 2020.
[23] Keikko T., Isokorpi J., Korpinen L., Practical problems in calculating electric fields of transmission lines, Eleventh International Symposium on High Voltage Engineering, London, UK, vol. 2, pp. 103–106 (1999).
Go to article

Authors and Affiliations

Chang-Qiong Yang
1
ORCID: ORCID
Mai Lu
1
ORCID: ORCID

  1. Lanzhou Jiaotong University, China

This page uses 'cookies'. Learn more