Lightning is one of the causes of transmission disorders and natural phenomena that cannot be avoided. The South Sulawesi region is located close to the equator and has a high lightning density. This condition results in lightning susceptibility of disturbances to electrical system lines, especially in high-voltage airlines and substations. An Adaptive Neuro-Fuzzy Inference System (ANFIS) will show the Root Mean Square Error (RMSE) based on the membership function type. This journal is to predict the value of the transmission tower lightning density using the ANFIS method. The value of the lightning strike density index can later be determined based on ANFIS predictions. Analysis of the value calculation system of structural lightning strikes in the South Sulawesi region of the Sungguminasa-Tallasa route can be categorized as three characteristics lightning density (Nd). The calculation system results for the value of structural lightning struck in the South Sulawesi region and validated between manual calculations and ANFIS with an average percentage of 0.0554%.
Go to article

Bibliography

[1] Utomo B.T., Nappu M.B., Said S.M., Arief A., The Placement of the Transmission Lightning Arrester (TLA) at 150 kV Network using Fuzzy Logic, in 2018 10th International Conference on Information Technology and Electrical Engineering (ICITEE), pp. 347–352 (2018).
[2] Rawi I.M., Kadir M.Z.A.A., Azis N., Lightning study and experience on the first 500kV transmission line arrester in Malaysia, in 2014 International Conference on Lightning Protection (ICLP), pp. 1106–1109 (2014), DOI: 10.1109/ICLP.2014.6973289.
[3] Gassing, Analisis Sistem Proteksi Petir (Lighting Performance) Pada Sutt 150 kV Sistem Sulawesi Selatan, vol. 6, pp. 978–979 (2012).
[4] Apriyadi M., Manjang S., Nappu M.B., Tegangan Impuls Dan Arus Transien Jaringan Transmisi 150 kV Sinjai-Bone Akibat Sambaran Petir Menggunakan ATPDraw, Jurnal Sains dan Teknologi, vol. 3, no. 2, pp. 156–164 (2014).
[5] Lembang N., Manjang S., Kitta I., Efek Penurunan Tahanan Pembumian Tower 150 kV terhadap Sistem Penyaluran Petir, J. Penelit. Enj., vol. 21, no. 2, pp. 7–15 (2017).
[6] Islam M.Z., Rashed M.R., Yusuf M.S.U., ATP-EMTP modeling and performance test of different type lightning arrester on 132kv overhead transmission tower, in 2017 3rd International Conference on Electrical Information and Communication Technology (EICT), pp. 1–6 (2017).
[7] Houari K., Hartani T., Remini B., Lefkir A., Abda L., Heddam S., A hybrid model for modelling the salinity of the Tafna River in Algeria, J. Water L. Dev., vol. 40, no. 1, pp. 127–135 (2019).
[8] Gubán M., Kása R., Takács D., Avornicului M., Trends of using artificial intelligence in measuring innovation potential, Manag. Prod. Eng. Rev., vol. 10 (2019).
[9] Jang J.S.R., MATLAB: Fuzzy logic toolbox user’s guide: Version 1 (1997).
[10] Said S.M., Latief S., Determination Of Sensorless Input Parameters Of Solar Panel With Adaptive Neuro-Fuzzy Inference System (Anfis) Methods, Indonesia (2018).
[11] Marsudi D., Operasi Sistem Tenaga Listrik (2006).
[12] Ishii M. et al., Multistory transmission tower model for lightning surge analysis, IEEE Trans. Power Deliv., vol. 6, no. 3, pp. 1327–1335 (1991).
[13] Ito T., Ueda T., Watanabe H., Funabashi T., Ametani A., Lightning flashovers on 77-kV systems: observed voltage bias effects and analysis, IEEE Trans. Power Deliv., vol. 18, no. 2, pp. 545–550 (2003).
[14] Correia M.T., Festas J., Milheiras H., FelizardoN., Fernadez M., Sousa J., Methodologies for evaluating the lightning performance of transmission lines, ICOLIM (1998).
[15] Oktaviani W.A., Hati I.P., Efektifitas Perlindungan Kawat Tanah Jaringan SUTM 20 kV Gardu Induk Boom Baru Palembang, PROtek J. Ilm. Tek. Elektro, vol. 6, no. 2, pp. 90–95 (2019).
[16] Nugroho A., Syakur A., Penentuan Lokasi Pemasangan Lightning Masts Pada Menara Transmisi Untuk Mengurangi Kegagalan Perlindungan Akibat Sambaran Petir, Transmisi, vol. 7, no. 1, pp. 31–36 (2005).
[17] Simon R., Geetha A., Comparison on the performance of Induction motor control using fuzzy and ANFIS controllers, in 2013 IEEE International Conference ON Emerging Trends in Computing, Communication and Nanotechnology (ICECCN), pp. 491–495 (2013).
[18] Lincy L.M., Senthil K.R., Comparison Analysis of Fuzzy Logic and ANFIS Controller for Mitigation of Harmonics, Proc. 4th Int. Conf. Electr. Energy Syst. ICEES 2018, pp. 578–583 (2018).
[19] Rahman M.M.A., Rahim A., Performance evaluation of ANN and ANFIS based wind speed sensorless MPPT controller, in 2016 5th International Conference on Informatics, Electronics and Vision (ICIEV), pp. 542–546 (2016).
[20] Ali M., Nurohmah H., Raikhani A., Sopian H., Sutantra N., Combined ANFIS method with FA, PSO, and ICA as Steering Control Optimization on Electric Car, in 2018 Electrical Power, Electronics, Communications, Controls and Informatics Seminar (EECCIS), pp. 299–304 (2018).
[21] Aniserowicz K., Analytical calculations of surges caused by direct lightning strike to underground intrusion detection system, Bull. Polish Acad. Sci. Tech. Sci., vol. 67, no. 2 (2019).
Go to article

Authors and Affiliations

Sri Mawar Said
1
Muhammad Bachtiar Nappu
1
Andarini Asri
2
Bayu Tri Utomo
1

  1. Hasanuddin University, Indonesia
  2. Ujung Pandang State Polytechnic, Indonesia