Abstrakt

The paper presents the results of model studies on the hydrodynamics of the world's first supercritical circulating fluidized bed boiler Lagisza 460 MWe, carried out on a scale model built in a scale of 1/20 while preserving the full geometrical similarity. To reflect the macroscopic pattern of flow in the boiler's combustion chamber, tests were carried out based on two dimensionless flow dynamic similarity criteria, while maintaining a constant Froude number value between the commercial and the scaled-down units. A mix of polydispersion solids with its fractional composition determined by scaling down the particle size distribution of the boiler's inert material was utilised for the tests using a special scaling function. The obtained results show very good agreement with the results of measurements taken on the Lagisza 460 MWe supercritical CFB boiler.

Przejdź do artykułu

Autorzy i Afiliacje