Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Dynamic charge carrier transport behavior in the zirconium (Zr) oxide was investigated based on the frequency-dependent capacitance-voltage (C-V) and temperature-dependent current-voltage (I-V) measurements. The Zr oxide was formed on the ZIRLO and newly developed zirconium-based alloy (NDZ) by corrosion in the PWR-simulated loop at 360°C. The corrosion test for 90 days showed that the NDZ exhibits better corrosion resistance than ZIRLO alloy. Based on the C-V measurement, dielectric constant values for the Zr oxide was estimated to be 11.28 and 11.52 for the ZIRLO and NDZ. The capacitance difference between low and high frequency was larger in the ZIRLO than in the NDZ, which was attributed to more mobile electrical charge carriers in the oxide layer on the ZIRLO alloy. The current through the oxide layers on the ZIRLO increased more drastically with increasing temperature than on the NDZ, which indicating that more charge trap sites exist in the ZIRLO than in NDZ. Based on the dynamic charge carrier transport behavior, it was concluded that the electrical charge carrier transport within the oxide layers was closely related with the corrosion behavior of the Zr alloys.

Go to article

Authors and Affiliations

Il-Kyu Park
Sang-Seok Lee
Yong Kyoon Mok
Chan-Woo Jeon
Hyun-Gil Kim
Download PDF Download RIS Download Bibtex

Abstract

The equivalent circuit of traditional capacitive voltage transformers often faces the problem of complex data calculation and difficulty in grasping the internal nonlinear characteristics of transformers when constructing broadband models, resulting in poor power accuracy and stability. Therefore, with the help of electromagnetic transient physical models, the admittance sub model and nonlinear model are established by considering the frequency and saturation characteristics of the transformer. Based on the characteristics of capacitive voltage transformers, the model is processed in parallel to obtain a broadband coupling transformer model. The results showed that the error between the simulated current peak amplitude and voltage results of the model and the measured values was less than 2% and 1%, respectively. In the fault results, the harmonic error of the load voltage of the improved transformer was relatively small, far less than the error result of 2.73% of the traditional transformer. The proposed transformer model can better characterize its characteristics and has good transient response ability, providing reference tools and value for the operation and state detection of power systems.
Go to article

Authors and Affiliations

Jie Geng
1
Haiyong Yang
1
Yi Li
1
Xiao Zhang
1
Yihang Wangb
1

  1. Office of Construction and Campus Planning, Tsinghua University Beijing 100084, China