Wyniki wyszukiwania

Filtruj wyniki

  • Czasopisma
  • Autorzy
  • Słowa kluczowe
  • Data
  • Typ

Wyniki wyszukiwania

Wyników: 3
Wyników na stronie: 25 50 75
Sortuj wg:

Abstrakt

In the external target experiment for heavy ion collisions in the HIRFL-CSR, Multi-Wire Drift Chambers are used to measure the drift time of charged particles to obtain the track information. This 128-channel high precision time measurement module is designed to perform the time digitization. The data transfer is based on a PXI interface to guarantee a high data rate. Test results show that a 100 ps resolution with a data transfer rate up to 40 MBps has been achieved; this module has also been proven to function well with the detector through a commissioning test.

Przejdź do artykułu

Autorzy i Afiliacje

Longfei Kang
Lei Zhao
Jiawen Zhou
Qi An

Abstrakt

On the basis of induction heating, radiation heating and liquid nitrogen refrigeration, high-temperature, medium-temperature, normal-temperature and low-temperature heating/refrigeration furnaces were designed, respectively. An apparatus with a wide temperature range and high accuracy applied to test oxidation resistance of materials has been developed based on the thermogravimetric method and the heat transfer principle. The apparatus consists of four heating/cooling systems, a specimen fixture positioning unit, a laser positioning unit, vertical and horizontal moving guide rails, and a high-precision weighing balance. The apparatus, based on the thermogravimetric method, is able to test oxidation resistance of materials. In the test, the temperature range was −180∼3000◦C (the highest temperature is determined by material properties). The temperature control accuracy was ±5◦C. The accuracy of on-line weighing was ±0:1 mg. The measurement uncertainty was 0.2 mg. Compared with other relevant devices, this apparatus has its own advantages: simple operation, wide heating/cooling temperature range, sufficient specimen heating, high sensitivity and precision, and short heating/cooling time. The experimental results show that the developed apparatus presented in this study not only can be used for isothermal thermogravimetric tests, but also for thermal cycling tests and multi-step oxidation tests. With the effective integration of multiple heating apparatus and refrigeration apparatus, the apparatus breaks through the limitations of the heating/cooling temperature range of the existing devices, accomplishes the high-precision oxidation resistance test of materials in a wide temperature range, and will play a great role in improving the research of materials.

Przejdź do artykułu

Autorzy i Afiliacje

Dong-Yang An
Jing-Min Dai
Peng Xiao

Abstrakt

In this paper the stability of a closed-loop cascade control system in the trajectory tracking task is addressed. The considered plant consists of underlying second-order fully actuated perturbed dynamics and the first order system which describes dynamics of the input. The main theoretical result establishes the conditions for Lyapunov stability formulated for the perturbed cascade control structure taking advantage of the active rejection disturbance approach. In particular, limitations imposed on a feasible set of an observer bandwidth are discussed. In order to illustrate characteristics of the closed-loop control system simulation results are presented. Furthermore, the particular implementation of the cascade control algorithm is verified experimentally using a two-axis telescope mount. The obtained results confirm that the considered control strategy can be efficiently applied for a class of mechanical systems when a high position tracking precision is required.

Przejdź do artykułu

Autorzy i Afiliacje

Radosław Patelski
Dariusz Pazderski

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji