Implementation of European directives is closely related to the quality of production and the associated operational safety, maintenance of machines and mechanical systems, both mobile or stationary, in order to reduce the dynamic load (vibration and noise) on the working environment, not only during their operating state but also during their design, production, and setting of the vibration isolation components. Reducing the dynamic load of mechanical systems and their components is reflected in the working environment by reduced emissions and immissions of noise and vibration. The presented paper investigates the methods and conditions for noise and vibration control, focusing mainly on increasing the quality of rotating machine components, such as bearings by means of effective vibration isolation of the machines. The solution of this problem requires theoretical analysis and methodology for the measurement of the mechanical systems involved. The results of the vibroacoustic measurements were analysed in terms of the low frequency vibration and noise level (quality) of bearings and conditions for effective vibration isolation of the machines using vibroacoustic diagnostic method. Furthermore, the impact on the working environment was also analysed. Finally, the paper suggests some actions to be taken to effectively reduce the unwanted vibrosound energy in working places, also using recycled material as a vibration isolation element.
A novel method of active noise control using adaptive radiation sound sources is investigated. A finite element model of a modal enclosed sound field is excited harmonically, representing a noise field in the low-frequency range. The control sources are comprised of elementary dipole sources for which the driving signals are adjusted by an optimization method. Two set-up cases of the proposed compound sources are investigated. The coupling of the control sources with the modal sound field is discussed. The simulated performance of the proposed method is compared with that of a system with distributed simple sources and the results show the effectiveness of the sources with adaptive radiation for active noise control in small enclosures.
Passive noise reduction methods require thick and heavy barriers to be effective for low frequencies and those clasical ones are thus not suitable for reduction of low frequency noise generated by devices. Active noise-cancelling casings, where casing walls vibrations are actively controlled, are an interesting alternative that can provide much higher low-frequency noise reduction. Such systems, compared to classical ANC systems, can provide not only local, but also global noise reduction, which is highly expected for most applications. For effective control of casing vibrations a large number of actuators is required. Additionally, a high number of error sensors, usually microphones that measure noise emission from the device, is also required. All actuators have an effect on all error sensors, and the control system must take into account all paths, from each actuator to each error sensor. The Multiple Error FXLMS has very high computational requirements. To reduce it a Switched-Error FXLMS, where only one error signal is used at the given time, have been proposed. This, however, significantly reduces convergence rate. In this paper an algorithm that uses multiple errors at once, but not all, is proposed. The performance of various algorithm variants is compared using simulations with the models obtained from real active-noise cancelling casing.
In the article a short historical outline of noise control conferences organized in Poland is given. Those conferences with the participation of Polish specialists have been organized since 1964; since 1976 they have been evolved into International Noise Control Conferences. Silhouettes of four Polish scientists, which have made a large contribution to the noise and vibration control in Poland, are presented. Also the current state of threats by noise and vibrations have been briefly mentioned. The significance of such conferences has been emphasized.
In the paper the author has described the visualization methods in acoustic flow fields and show how these methods may assist scientists to gain understanding of complex acoustic energy flow in real-life field. A graphical method will be presented to determine the real acoustic wave distribution in the flow field. Visualization of research results, which is unavailable by conventional acoustics metrology, may be shown in the form of intensity streamlines in space, as a shape of floating acoustic wave and intensity isosurface in three-dimensional space. In traditional acoustic metrology, the analysis of acoustic fields concerns only the distribution of pressure levels (scalar variable), however in a real acoustic field both the scalar (acoustic pressure) and vector (the acoustic particle velocity) effects are closely related. Only when the acoustic field is described by both the potential and kinetic energies, we may understand the mechanisms of propagation, diffraction and scattering of acoustic waves on obstacles, as a form of energy image. This attribute of intensity method can also validate the results of CFD/CAA numerical modeling which is very important in any industry acoustic investigations.
The development of digital signal processors and the increase in their computing capabilities bring opportunities to employ algorithms with multiple variable parameters in active noise control systems. Of particular interest are the algorithms based on artificial neural networks. This paper presents an active noise control algorithm based on a neural network and a nonlinear input-output system identification model. The purpose of the algorithm is an active noise control system with a nonlinear primary path. The algorithm uses the NARMAX system identification model. The neural network employed in the proposed algorithm is a multilayer perceptron. The error backpropagation rule with adaptive learning rate is employed to update the weight of the neural network. The performance of the proposed algorithm has been tested by numerical simulations. Results for narrow-band input signals and nonlinear primary path are presented below.
The assessment of the uncertainty of measurement results, an essential problem in environmental acoustic investigations, is undertaken in the paper. An attention is drawn to the - usually omitted - problem of the verification of assumptions related to using the classic methods of the confidence intervals estimation, for the controlled measuring quantity.
Especially the paper directs attention to the need of the verification of the assumption of the normal distribution of the measuring quantity set, being the base for the existing and binding procedures of the acoustic measurements assessment uncertainty. The essence of the undertaken problem concerns the binding legal and standard acts related to acoustic measurements and recommended in: 'Guide to the expression of uncertainty in measurement' (GUM) (OIML 1993), developed under the aegis of the International Bureau of Measures (BIPM). The model legitimacy of the hypothesis of the normal distribution of the measuring quantity set in acoustic measurements is discussed and supplemented by testing its likelihood on the environment acoustic results.
The Jarque-Bery test based on skewness and flattening (curtosis) distribution measures was used for the analysis of results verifying the assumption. This test allows for the simultaneous analysis of the deviation from the normal distribution caused both by its skewness and flattening. The performed experiments concerned analyses of the distribution of sound levels: LD, LE, LN, LDWN, being the basic noise indicators in assessments of the environment acoustic hazards.
Noise control has gained a lot of attention recently. However, presence of nonlinearities in signal paths for some applications can cause significant difficulties in the operation of control algorithms. In particular, this problem is common in structural noise control, which uses a piezoelectric shunt circuit. Not only vibrating structures may exhibit nonlinear characteristics, but also piezoelectric actuators. In this paper, active device casing is addressed. The objective is to minimize the noise coming out of the casing, by controlling vibration of its walls. The shunt technology is applied. The proposed control algorithm is based on algorithms from a group of soft computing. It is verified by means of simulations using data acquired from a real object.
Limited Traffic Zone (LTZ) is a planning strategy that is more and more adopted by municipalities in Europe to improve their environmental conditions. It consists in the prohibition for traditional vehicles to circulate in specific areas. Although the main aim is to tackle air pollution problems, positive effects are registered in terms of reduction of noise annoyance and in terms of improved “quality of life” if specific conditions are respected. On the other side under the drive of the global market, the number of circulating electric vehicles in urban sites is also increasing. In the next years we expect to experience a new and not well-known urban soundscape.
In this paper is presented an overview of recent urban projects and policies that deal with noise control and how these experiences will match into the next years with the sound characteristics of new electric vehicles for private and public transportation.
The paper presents results of the localization of main noise sources in the industrial plant. Identification of main noise sources was made with an acoustic camera using Beamforming Method. Parallel to the measurements by means of the acoustic camera, sound level measurements on the main noise sources have been performed. Based on the calculations, prediction regarding the noise emission at residential buildings located near to the plant has been determined. Acoustic noise maps have been performed with LEQ Professional software, which includes the 3D geometry of the buildings inside the plant. It has been established that, after introduction of noise reduction measures in the plant, the noise levels at the observation points in the residential area meets the limit values.
There are many industrial environments which are exposed to a high-level noise. It is necessary to protect people from the noise. Most of the time, the consumer requires a miniature version of a noise canceller to satisfy the internal working place requirements. Very important thing is to select the most appropriate personal hearing protection device, for example an earplug. It should guarantee high passive noise attenuation and allow for secondary sound generation in case of active control. In many cases the noise is nonstationary. For instance, some of the noisy devices are switched on and off, speed of some rotors or fans changes, etc. To avoid any severe transient acoustic effects due to potential convergence problems of adaptive systems, a fixed-parameter approach to control is appreciated. If the noise were stationary, it would be possible to design an optimal control filter minimising variance of the signal being the effect of the acoustic noise and the secondary sound interference. Because of noise nonstationarity for most applications, the idea of generalised disturbance defined by a frequency window of different types has been developed by the authors and announced in previous publications. The aim of this paper is to apply such an approach to different earplugs and verify its noise reduction properties. Simulation experiments are conducted based on real world measurements performed using the G. R. A. S. artificial head equipped with an artificial mechanical ear, and the noise recorded in a power plant.
For many adaptive noise control systems the Filtered-Reference LMS, known as the FXLMS algorithm is used to update parameters of the control filter. Appropriate adjustment of the step size is then important to guarantee convergence of the algorithm, obtain small excess mean square error, and react with required rate to variation of plant properties or noise nonstationarity. There are several recipes presented in the literature, theoretically derived or of heuristic origin.
This paper focuses on a modification of the FXLMS algorithm, were convergence is guaranteed by changing sign of the algorithm steps size, instead of using a model of the secondary path. A TakagiSugeno-Kang fuzzy inference system is proposed to evaluate both the sign and the magnitude of the step size. Simulation experiments are presented to validate the algorithm and compare it to the classical FXLMS algorithm in terms of convergence and noise reduction.
The Least Mean Square (LMS) algorithm and its variants are currently the most frequently used adaptation algorithms; therefore, it is desirable to understand them thoroughly from both theoretical and practical points of view. One of the main aspects studied in the literature is the influence of the step size on stability or convergence of LMS-based algorithms. Different publications provide different stability upper bounds, but a lower bound is always set to zero. However, they are mostly based on statistical analysis. In this paper we show, by means of control theoretic analysis confirmed by simulations, that for the leaky LMS algorithm, a small negative step size is allowed. Moreover, the control theoretic approach alows to minimize the number of assumptions necessary to prove the new condition. Thus, although a positive step size is fully justified for practical applications since it reduces the mean-square error, knowledge about an allowed small negative step size is important from a cognitive point of view.
In the areas of acoustic research or applications that deal with not-precisely-known or variable conditions, a method of adaptation to the uncertainness or changes is usually necessary. When searching for an adaptation algorithm, it is hard to overlook the least mean squares (LMS) algorithm. Its simplicity, speed of computation, and robustness has won it a wide area of applications: from telecommunication, through acoustics and vibration, to seismology. The algorithm, however, still lacks a full theoretical analysis. This is probabely the cause of its main drawback: the need of a careful choice of the step size - which is the reason why so many variable step size flavors of the LMS algorithm has been developed.
This paper contributes to both the above mentioned characteristics of the LMS algorithm. First, it shows a derivation of a new necessary condition for the LMS algorithm convergence. The condition, although weak, proved useful in developing a new variable step size LMS algorithm which appeared to be quite different from the algorithms known from the literature. Moreover, the algorithm proved to be effective in both simulations and laboratory experiments, covering two possible applications: adaptive line enhancement and active noise control.
It is possible to enhance acoustic isolation of the device from the environment by appropriately controlling vibration of a device casing. Sound insulation efficiency of this technique for a rigid casing was confirmed by the authors in previous publications. In this paper, a light-weight casing is investigated, where vibrational couplings between walls are much greater due to lack of a rigid frame. A laboratory setup is described in details. The influence of the cross-paths on successful global noise reduction is considered. Multiple vibration actuators are installed on each of the casing walls. An adaptive control strategy based on the Least Mean Square (LMS) algorithm is used to update control filter parameters. Obtained results are reported, discussed, and conclusions for future research are drawn.
Nowadays, noise generated by devices is a serious issue in industry and in everyday life, because it may cause health damage to humans. In this research, a cubic rigid device casing built of double-panel thin steel walls is employed to reduce noise emitted from an enclosed noise source. Double-panel structure is used because of good sound insulation it provides. There exist three main groups of noise reduction methods, i.e. passive, semi-active and active. In this paper, a semi-active modification of double-panel structure is applied and examined. The bistable actuator (solenoid) mounted between incident and radiating plates changes its state due to applied constant voltage, causing the coupling of plates. Experimentally measured natural frequencies and modeshapes of the structure are compared to the simulation results. The influence of proposed modification on dynamical properties of the structure is analyzed and discussed.
There are many industrial environments which are exposed to a high-level noise, sometimes much higher than the level of speech. Verbal communication is then practically unfeasible. In order to increase the speech intelligibility, appropriate speech enhancement algorithms can be used. It is impossible to filter off the noise completely from the acquired signal by using a conventional filter, because of two reasons. First, the speech and the noise frequency contents are overlapping. Second, the noise properties are subject to change. The adaptive realisation of the Wiener-based approach can be, however, applied. Two structures are possible. One is the line enhancer, where the predictive realisation of the Wiener approach is used. The benefit of using this structure it that it does not require additional apparatus. The second structure takes advantage of the high level of noise. Under such condition, placing another microphone, even close to the primary one, can provide a reference signal well correlated with the noise disturbing the speech and lacking the information about the speech. Then, the classical Wiener filter can be used, to produce an estimate of the noise based on the reference signal. That noise estimate can be then subtracted from the disturbed speech. Both algorithms are verified, based on the data obtained from the real industrial environment. For laboratory experiments the G. R. A. S. artificial head and two microphones, one at back side of an earplug and another at the mouth are used.