Wyniki wyszukiwania

Filtruj wyniki

  • Czasopisma
  • Autorzy
  • Słowa kluczowe
  • Data
  • Typ

Wyniki wyszukiwania

Wyników: 6
Wyników na stronie: 25 50 75
Sortuj wg:

Abstrakt

The purpose of the work was initial modification of the construction of a commercially produced heat exchanger – recuperator with CFD (computational fluid dynamics) methods, based on designs and process parameters which were provided. Uniformity of gas distribution in the space between the tubes of the apparatus as well as the pressure drop in it were taken as modification criteria. Uniformity of the gas velocity field between the tubes of the heat exchanger should cause equalization of the local individual heat transfer coefficient values and temperature value. Changes of the apparatus construction which do not worsen work conditions of the equipment, but cause savings of constructional materials (elimination or shortening some parts of the apparatus) were taken into consideration.

Przejdź do artykułu

Autorzy i Afiliacje

Wojciech Ludwig
Daniel Zając

Abstrakt

W celu doboru optymalnych warunków prowadzenia procesu odzyskiwania ciepła z tlenowego kompostowania przeprowadzono trzy etapy badań polegające na rejestracji wartości strumienia odzyskiwanego ciepła wraz z obserwacją wpływu chłodzenia na parametry procesu kompostowania. Zmierzono wartości współczynnika przewodności cieplnej kompostu w zależności od jego temperatury, gęstości i wieku. Wartości wahały się w granicach: 0,171-0,300 W/mK. Dobrano optymalne warunki prowadzenia procesu. Dla nich oszacowano, ile ciepła można będzie odzyskiwać podczas kompostowania na skalę przemysłową przy zastosowaniu baterii wymienników. Dla sztucznie napowietrzanej pryzmy o wymiarach: podstawa dolna 8 m, podstawa górna 5 m, wysokość 3,5 m, długość 3 m; można będzie odzyskiwać około 7,4 kW (z 1 m2 powierzchni wymiennika 774 W).
Przejdź do artykułu

Autorzy i Afiliacje

Ewa Klejment
Marian Rosiński
Pobierz PDF Pobierz RIS Pobierz Bibtex

Abstrakt

The research provides a thermodynamic analysis of the theoretical model of a ventilation and air conditioning heat pump system with the ventilation air cold energy recovery depending on outside air parameters, the recovery efficiency and characteristics of a premise. A confectionery production workshop was taken as a prototype where technological conditions (temperature and humidity) must be maintained during the warm season. Calculations using the method of successive approximations to estimate air parameters at system’s nodal points were conducted. It allowed to determine theoretical refrigeration efficiency of the studied system and proved advantages of heat recuperation for smaller energy consumption. The model can be applied for design of heating, ventilation, and air conditioning units which work as a heat pump. The studied system has the highest energy efficiency in the area of relatively low environment temperatures and relative humidity which is suitable for countries with temperate continental climates characterized by low relative humidity.
Przejdź do artykułu

Bibliografia

[1] Zhang J., Zhang H.-H., He Y.-L., Tao W.-Q.: A comprehensive review on advances and applications of industrial heat pumps based on the practices in China. Appl. Energ. 178(2016), 800–825.
[2] Chwieduk D.: Analysis of utilization of renewable energies as heat sources for heat pumps in building sector. Renew. Energ. 9(1996), 720–723.
[3] Khrustaliov B.M.: Heat Supply and Ventilation. ASV, Moscow 2007 (in Russian).
[4] Mazzeo D.: Solar and wind assisted heat pump to meet the building air conditioning and electric energy demand in the presence of an electric vehicle charging station and battery storage. J. Clean. Prod. 213(2019), 1228–1250.
[5] Chwieduk B., Chwieduk D.: Analysis of operation and energy performance of a heat pump driven by a PV system for space heating of a single family house in Polish conditions. Renew. Energ. 165(2021), 117–126.
[6] Bezrodny M., Prytula N., Tsvietkova M.: Efficiency of heat pump systems of air conditioningfor removing excessive moisture. Arch. Thermodyn. 40(2019), 2, 151–165.
[7] Bezrodny E.K., Misiura T.O.: The heat pump system for ventilation and air conditioning inside the production area with an excessive internal moisture generation. Eurasian Phys. Tech. J. 17(2020), 118–132.
[8] Adamkiewicz A., Nikonczuk P.: Waste heat recovery from the air preparation room in a paint shop. Arch. Thermodyn. 40(2019), 3, 229–241.
[9] Szreder M.: Investigations into the influence of functional parameters of a heat pump on its thermal efficiency. Teka. Commission of Motorization and Energetics in Agriculture 13(2013), 191–196.
[10] Redko A., Redko O., DiPippo R.: Low-Temperature Energy Systems with Applications of Renewable Energy. Academic Press, Elsevier, 2020.
[11] Morozjuk T.V.: The Theory of Chillers and Heat Pumps. Studija “Negociant”, Odessa 2006 (in Russian).
[12] Jaber S., Ezzat A.W.: Investigation of energy recovery with exhaust air evaporative cooling in ventilation system. Energ. Buildings 139(2017), 439–448.
[13] Bozhenko M.F.: Heat Sources and Heat Consumers. NTUU KPI “Politehnika”, Kyiv 2004 (in Ukrainian).
[14] State Building Standards of Ukraine DBN B.2.5-67: 2013, “Heating, ventilation and air conditioning”. Ministry of Regional Development, Construction and Housing of Ukraine, Kyiv 2013 (in Ukrainian).
Przejdź do artykułu

Autorzy i Afiliacje

Myhailo Kostiantynovych Bezrodny
1
Tymofii Oleksiyovych Misiura
1

  1. National Technical University of Ukraine, Igor Sikorsky, Kyiv Polytechnic Institute, Prosp. Peremohy 37, 03056 Kyiv, Ukraine

Abstrakt

W niniejszym artykule spróbuję wskazać, czego uczą się korporacje od ruchów miejskich. W proponowanej analizie odwołam się do koncepcji rekuperacji i ducha kapitalizmu Luca Boltanskiego i Ève Chiapello. Ponadto przywołam pracę tych autorów, którzy analizowali powstanie i działalność ruchów miejskich w kontekście krytyki kapitalizmu i systemu neoliberalnego.

Przejdź do artykułu

Autorzy i Afiliacje

Jan Śpiewak

Abstrakt

Celem pracy było określenie, czy proces kompostowania odpadów komunalnych może być niskotemperaturowym źródłem ciepła. Określono, że w trakcie wysokotemperaturowej fazy procesu powstaje średnio 930,5 kJ/kg kompostu. W zaprojektowanym i wykonanym modelu laboratoryjnym przeprowadzono trzy etapy badań, polegające na prowadzeniu procesu kompostowania z jednoczesnym odzyskiwaniem ciepła z procesu. Na podstawie badań określono parametry mające wpływ na efektywność procesu odzyskiwania ciepła; a mianowicie: optymalna początkowa temperatura wody chłodzącej powinna wynosić około 30°C, obniżanie strumienia przepływu wody chłodzącej wpływa korzystnie na wzrost efektywności procesu, natomiast bezpieczna temperatura, do której można schłodzić kompost nie powinna przekroczyć 52°C (co gwarantuje jego czystość pod względem sanitarnym). Zaobserwowano również, że wraz z wydłużaniem się wieku kompostu maleje efektywność procesu odzyskiwania ciepła.
Przejdź do artykułu

Autorzy i Afiliacje

Ewa Klejment
Marian Rosiński

Abstrakt

The Authors present the problems of theoretical analysis and experimental research related to the possibilities of energy recovery in selected phases of operating and running cycles of self-driven crane. Heavy machinery powered by diesel engines is a source of solid toxic emissions. In order to limit these emissions, one install filters and filter regeneration systems. According to the concept presented here, the recovered energy might be utilised for regeneration of these filters by burning off accumulated solid particles (soot). Mechanical energy would be the power source to drive DC generators - the mechanical-into-electric energy converters. Filter's heating resistors, acting as the generators' load, would radiate a power of 3-;-5 MJ to initiate burning of soot in the filter. The calculations of energy consumed during sheave block lowering phase were made for three different lifting capacities taking into account the boom length and crane reach. Three running cycles of the crane: highroad, urban and off-road ones were also analysed. The time functions of variations of crane running speed and power of motion resistance at driving wheels were found. The results provided the background for determination of theoretical values of energy to be regained during braking phase of the analysed cycles. The structure and operation of experimental stands was discussed. The stands contain units that, at proper size factor, represent the processes that occur in real cranes and that are related only to energy recovery. Computer software for system simulation, control and measurement was described. Measurement results and result analysis are presented. The value of energy found theoretically was compared with the energy recovered during experimental tests. The paper also contains simplified kinematic schemes of selected units of crane lifting and driving systems, including an additional DC generator. This concept, however, needs verification in future design solutions.
Przejdź do artykułu

Autorzy i Afiliacje

Jerzy Ocioszyński
Przemysław Majewski