Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 33
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Green roofs play a significant role in sustainable drainage systems. They form absorbent surfaces for rainwater, which they retain with the aid of profile and plants. Such roofs therefore take an active part in improving the climatic conditions of a city and, more broadly, the water balance of urbanized areas. One of the factors influencing the hydrological efficiency of green roofs is the drainage layer. In the article, column studies were carried out under field conditions involving the comparison of the retention abilities of two aggregates serving as the drainage layer of green roofs, i.e. Leca® and quartzite grit. The average retention of the substrate was 48%; for a 5 cm drainage layer of Leca® retention was 57%, for a 10 cm layer of Leca average retention was 61%. For a 5 cm layer of quartzite grit average retention was 50%, for 10 cm layer of quartzite grit 53%. The highest retention was obtained for the column with the substrate and 10-centimeter layer of Leca®. At the same time, it was shown that Leca® is a better retention material than quartzite grit. The initial state of substrate moisture content from a green roof appears to be a significant factor in reducing rainfall runoff from a green roof; the ob-tained values of initial moisture content made for a higher correlation than the antecedent dry weather period.

Go to article

Authors and Affiliations

Anna M. Baryła
Download PDF Download RIS Download Bibtex

Abstract

This article focuses on the difficulties in ensuring longwall stability resulting from the wrong geometric form of the structure of powered support sections. The authors proved, based on the in-situ measurements and numerical calculations, that proper cooperation of the support with the rock mass requires correct determination of the support point for the hydraulic legs along the length of the canopy (ratio), as well as the inclination of the shield support of the section of the powered roof support. The lack of these two fundamental elements may lead to roof drops that directly impact the production results and safety of the people working underground. Another matter arising from the incorrect geometric form of the construction are the values of forces created in the node connecting the canopy with the caving shield, which can make a major contribution to limit the practical range of the operational height of the powered roof support (due to interaction of powered support with rockmass) in terms of the operating range offered by the manufacturer of the powered support. The operating of the powered roof support in some height ranges may hinder, or even in certain cases prevent, the operator of powered support, moving the shields and placing them with the proper geometry (ensuring parallelism between the canopy and the floor bases of the section).

Go to article

Authors and Affiliations

Sylwester Rajwa
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

Effective use of energy in various branches of economy is one of world trends in development of power engineering. Relevant energy consumption occurs during exploitation of buildings, so there is still potential to diminish it as far as heating, ventilation, and air conditioning are concerned. Particularly in summer season, the choice of respective roofing colour can play a decisive role for the heat flux transferred to the inside of the object. Decrease of heat flux causes a lower heat burden to the building and lower power consumption by the air conditioning systems. In winter, on the contrary, heat flux transferred to building’s interior should be higher, as a result, demand of energy for heating will be lower. However, calculations of the heat flux require that energy balance must be made for the object. Unfortunately, not all producers of roofing covers inform about the values of reflectivity and thermal emissivity of their products, which is, in turn, necessary for calculations. In the present paper, research methodology elaborated by authors is proposed for determination of thermal emissivity of roofing covers. The paper presents test stand, methodology, and research results for roofing paper in blue colour (as an example) for which the thermal emissivity is an unknown parameter.

Go to article

Authors and Affiliations

Zbigniew Zapałowicz
Anna Walterowicz
Download PDF Download RIS Download Bibtex

Abstract

This article deals with the problem of determining the resistance of end-plate connections. A nonlinear FEM model of the joint was constructed in order to predict its carrying capacity. A standard code procedure was done as well. The analyses have been done to assess atypical end-plate joints designed and constructed as a part of roof structures.

Go to article

Authors and Affiliations

K. Żółtowski
P. Kalitowski
Download PDF Download RIS Download Bibtex

Abstract

The article presents the results of tests on SHC-40 hydraulic props equipped with two types of valve blocks: standard (with spring steel cylinder) and BZG-2FS (with gas spring). The research was conducted using impact mass of 4,000 kg and with extreme dynamic load of free fall impact mass of 20,000 kg released from different heights h. The dynamic tests involved a camera with the speed of image capture up to 1,200 frames/sec, which made it possible to register the stream of liquid at the dynamic load and to determine the valve opening time. The study conducted on SHC-40 NHR10 props equipped with two types of valve blocks: a standard and the BZG-2FS fast acting relief, showed that the prop with the BZG-2FS block is more suitable and more effective in the case of areas with high risk of mining tremors and rapid stress relief of a seam. Research methodology developed in the Central Mining Institute combines digital recording technique of pressure in a prop and fast registration of the images, and allows to acquire more accurate analysis of dynamic phenomena in the prop during testing.
Go to article

Authors and Affiliations

Andrzej Pytlik
Download PDF Download RIS Download Bibtex

Abstract

The article shows the need to take into account the principles of sustainable development in the field of the revitalization of space, and point out green roofs as a tool in this process. It is presented in the light of the green city concept, and the criteria of the European Green City Index. The article shows the ecological, social and economic benefits of green roofs (starting from the retrieval of green areas in the urbanized space, the reduction of heat island effects, up to the integration function of green roofs), which is illustrated by a few case studies of applying green roofs within revitalization projects. The article indicates also legal incentives, as well as programs directed to the development of green roofs around the world, pointing out a range of factors to consider also for Polish cities.

Go to article

Authors and Affiliations

Karolina Życzkowska
Download PDF Download RIS Download Bibtex

Abstract

In this paper, transient analysis on heat transfer across the residential building roof having various materials like wood wool, phase change material and weathering tile is performed by numerical simulation technique. 2-dimensional roof model is created, checked for grid independency and validated with the experimental results. Three different roof structures are included in this study namely roof with (i). Concrete and weathering tile, (ii). Concrete, phase change material and weathering tile and (iii). Concrete, phase change material, wood wool and weathering tile. Roof type 3 restricts 13% of heat entering the room in comparison with roof having only concrete and weathering tile. Also the effect of various roof layers’ thickness in the roof type 3 is investigated and identifi ed that the wood wool plays the major role in arresting the entry of heat in to the room. The average reduction of heat is about 10% for an increase of a unit thickness of wood wool layer.

Go to article

Authors and Affiliations

D. Prakash
P. Ravikumar
Download PDF Download RIS Download Bibtex

Abstract

Geodesic measurements of mining area deformations indicate that their description fails to be regular,

as opposed to what the predictions based on the relationships of the geometric-integral theory suggest.

The Knothe theory, most commonly applied in that case, considers such parameters as the exploitation

coefficient a and the angle of the main influences range tgβ, describing the geomechanical properties of the

medium, as well as the mining conditions. The study shows that the values of the parameters a = 0.8 and

tgβ = 2.0, most commonly adopted for the prediction of surface deformation, are not entirely adequate in

describing each and every mining situation in the analysed rock mass. Therefore, the paper aims to propose

methodology for determining the value of exploitation coefficient a, which allows to predict the values

of surface subsidence caused by underground coal mining with roof caving, depending on geological and

mining conditions. The characteristics of the analysed areas show that the following factors affect surface

subsidence: thickness of overburden, type of overburden strata, type of Carboniferous strata, rock mass

disturbance and depth of exploitation. These factors may allow to determine the exploitation coefficient a,

used in the Knothe theory for surface deformation prediction.

Go to article

Authors and Affiliations

Katarzyna Kryzia
Tadeusz Majcherczyk
Zbigniew Niedbalski
Download PDF Download RIS Download Bibtex

Abstract

For centuries, the roof has been a reminiscence, the symbol of basic human shelter and territory. Using the example of several ethnic groups living in Southeast Asia, Bhutan and Poland, the basic determinants of roof shape creation in vernacular architecture are discussed and similarities highlighted. In wooden architecture in different regions of the world, the form and construction of the roof are determined primarily by local conditions: climatic conditions, available materials, local tradition, culture, customs. Often it is the shape of the roof that determines the visual identity of a given ethnic group, with its traditions and way of life. The author points out that societies from different regions of the world with no cultural ties created wooden architecture based on the same factors and that the similarities are already present at the level of thinking patterns resulting, for example, from the need to emphasize the importance of religious buildings by means of the stacked, pent hip form of the basic roof.
Go to article

Authors and Affiliations

Karolina Urszula Sobczyńska
1
ORCID: ORCID

  1. Poznań University of Technology Faculty of Architecture Division of History, Theory and Heritage Protection
Download PDF Download RIS Download Bibtex

Abstract

When mining coal from the working face, the main roof withstands the overlying strata. The main roof’s first weighting and periodic weighting may cause accidents, such as crushing the working face hydraulic supports. A mechanical model of the main roof was constructed, and the contributing factors of first and periodic weights on the main roof were examined in order to prevent such accidents. The thickness of the main roof was found as the most contributory factor to the main roof’s stability. Therefore, a new directional roof crack (DRC) technique is proposed, which produces directional cracks in the main roof through directional blasting and makes part of it collapse in advance so as to reduce the thickness and relieve the first and periodic weighting. To verify the effectiveness of DRC, the mechanism of DRC was analysed. A mechanical model of the hydraulic support was constructed, and the DRC techniques were tested on-site. Field experiments with a complete set of monitoring schemes showed that, with DRC technology, the roof periodic weighting interval decreased by 35.36%, and the hydraulic support pressure decreased by 17.56%. The theoretical analysis was consistent with the measured results. Therefore, the DRC technology is feasible and effective to ensure mining safety at the working face.
Go to article

Authors and Affiliations

Jun Zhang
1
ORCID: ORCID
Jianning Liu
1
ORCID: ORCID
Yajun Wang
2
ORCID: ORCID
Gang Yang
1
ORCID: ORCID
Shilin Hou
1
ORCID: ORCID
Yanjun Wang
3
ORCID: ORCID
Manchao He
1
ORCID: ORCID
Jun Yang
1
ORCID: ORCID

  1. China University of Mining & Technology (Beijing), State Key Laboratory for Geomechanics and Deep Underground Engineering, Beijing 100083, China
  2. School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
  3. ShanXiYinFeng Science & Technology CO. LTD, Taiyuan 030000, China
Download PDF Download RIS Download Bibtex

Abstract

The efficient protection (support reinforcement) of a wall and heading crossing ensures continuity of the production cycle, and that is a quick moving of the scraper conveyor to the wall. Using low or high bolting as a support reinforcement element in wall and heading crossings allows for the elimination of traditional methods of maintaining longwall-gate crossings, and therefore allows for the efficient use high performance modern wall complexes. The paper presents the long underground experience, of the Knurów–Szczygłowice mine of efficient support wall and heading crossing maintenance, which was bolted to the rock mass with the usage of two pairs of bolts, showing full technical and economical usefulness of this support reinforcement method. The article also highlights work safety and the increasingly common usage of endoscopies when specifying the range of crack areas which directly effects the proper choice in number, load-capacity and length of the used bolts. The underground studies the measurements of the reach of the zones of fracturing and roof stratification (using endoscopes and wire type stratification meters) and the laboratory tests (using the test stand) have allowed to determine the safety factor for maintenance of the longwall gangway crossing, directly resulting in the necessity to install additional reinforcement. The value of the safety factor Sbsc-ch greater than 1 is advantageous and safe, and the value less than or equal to 1 can lead to a significant deterioration of the conditions of maintenance of a wall and heading crossing which was bolted.

Go to article

Authors and Affiliations

Stanisław Duży
Piotr Głuch
Grzegorz Michalik
Adam Ratajczak
Download PDF Download RIS Download Bibtex

Abstract

The presented article describes the relationship between lithological and facies development of reservoir rocks in the area of the roof elevation of the Weissliegend sandstones, with a particular emphasis on the influence of elevation on the occurrence of low mineralization zones in the deposit area. To illustrate the variability of the deposit parameters, closely related to the facies and lithological conditions of the host rocks, three-dimensional lithological and geochemical models for two research areas were developed using the geostatistical methods and based on field observations and the sampling of the deposit. The research area includes parts of the Northern Elevation of Rudna and the surrounding depressions within the boundaries of the Sieroszowice and Rudna deposits. Based on cross-sections of the 3D models, a different deposit formation in the roof elevation area of sandstone formations has been characterized; the lithological profile is defined as „atypical” due to the absence of a copper-bearing shale series, the most characteristic layer for copper ore deposits in the Fore -Sudetic monocline. Large variations in the shape of the deposit and the irregular boundaries of both balance mineralization and enclaves of gangue have been confirmed. The presence of large-scale enclaves of igneous rock in the entire profile of the Lower Zechstein rocks (areas without the balance copper mineralization) and small areas of gangue (sandstone) enriched with anhydrite binders adjacent to the parts of balance deposit located in argillaceous sandstone has been revealed. The possibility of the occurrence of gangue, in the area of the roof elevation of the Weissliegend sandstones directly adjacent to the border with calcareous dolomite, and irregular gangue partings in sandstone formations in the balance deposit was indicated. In addition, small areas of strong enrichment in Cu sulphides were observed in the contact zones between sulphate and clay binders in the Weissliegend sandstone series.

Go to article

Authors and Affiliations

Wojciech Kaczmarek
Mariusz Dudek
Katarzyna Golda
Monika Wasilewska-Błaszczyk
Download PDF Download RIS Download Bibtex

Abstract

The work concerns the influence of the method of numerical modelling of the connections of the roof truss and vaults with the walls of historic masonry objects structures on the local stress distribution in the walls. At the outset, the need to search for rational modelling was justified due to the large size of the calculation models and the erroneous results obtained with oversimplification of the model. Four methods of modelling the connections between the walls and roof truss and vaults were analysed. The first method was to describe the elements of walls and foundations as solid elements, the ribs of the vaults and the roof truss as beam elements, and the vaulting webs as shell elements. The remaining methods 2–4 describe the walls as shell elements. In places where the walls join with the roof truss and vaults, fictitious/fictional elements in the form of rigid horizontally-oriented shells were used in model No. 2. In model No. 3, fictitious rigid horizontally-oriented shell elements in addition to local rigid vertically-oriented shells were used, while in model No. 4, only fictitious rigid vertically-oriented shell elements with stepwise decreasing protrusions were introduced. The best solution in terms of local stress distribution turned out to be the description of connections with fictitious shell elements in the case of model No. 4. This approach slightly increases the number of unknowns, and makes the results of stresses in the connection areas realistic in relation to full modelling with solid finite elements.
Go to article

Authors and Affiliations

Czesław Miedziałowski
1
ORCID: ORCID
Marcin Szkobodziński
2
ORCID: ORCID
Krzysztof Robert Czech
1
ORCID: ORCID

  1. Bialystok University of Technology, Faculty of Civil Engineering and Environmental Sciences, Wiejska 45A, 15-351 Bialystok, Poland
  2. Energoprojekty sp. z o.o., Opolska 15, 15-549 Bialystok, Poland
Download PDF Download RIS Download Bibtex

Abstract

The dynamic characteristics of the hydraulic leg are essential for determining the safe working range of roof supports operating in seams threatened by rock mass tremors. The systematic increase in the support of the hydraulic legs due to deteriorating geological-mining conditions has increased their diameters, which currently exceed 0.32 m for the 1st hydraulic stage. Evaluation of the dynamic properties of the roof support and the hydraulic legs are carried out by the Central Mining Institute through calculation methods as an implementation of the Regulation of the Minister of Energy on occupational safety and health. However, the issue of validating the calculations concerning natural scale studies still needs to be addressed. There are significant limitations in this area due to the technical and metrological capabilities of the testing stations. This paper presents an attempt to evaluate bench testing of a hydraulic leg with 0.32 m of the 1st hydraulic stage diameter for the validation of computational and test methods. Results of previous studies affecting the evaluation of the research methods used are also cited. According to the authors, the optimal and economically justifiable direction is to undertake model tests using numerical analyses and to validate these results, based on the study of models of hydraulic legs that are in use at a reduced scale. The construction of testing stations to ensure adequate dynamic loading for the support of the largest diameter hydraulic legs is currently not economically viable. The problem presented, however, is important given the constantly deteriorating geological-mining conditions and the associated threat of rock mass tremors.
Go to article

Authors and Affiliations

Kazimierz Stoiński
1
ORCID: ORCID
Marek Płonka
1
ORCID: ORCID
Janina Świątek
1
ORCID: ORCID

  1. Central Mining Institute (GIG ), 1 Gwarków Sq., 40-166 Katowice, Poland
Download PDF Download RIS Download Bibtex

Abstract

The use of computer techniques at the design stage of industrial facilities is essential in modern times. The ability to shorten the time required to develop a project and assess the safety of the use of assumptions, often enables the reduction of the costs incurred in the future. The possibility to skip expensive prototype tests by using 3D prototyping is why it is currently the prevailing model in the design of industrial facilities, including in the mining industry. In the case of a longwall working, its stability requires the maintenance of the geometric continuity of floor rocks in cooperation with a powered roof support.

The paper investigates the problem of longwall working stability under the influence of roof properties, coal properties, shield loading and the roof-floor interaction. The longwall working stability is represented by an index, factor of safety (FOS), and is correlated with a previously proposed roof capacity index ‘g‘. The topic of the paper does address an issue of potential interest.

The assessment of the stability of the roof in longwalls was based on the numerical analysis of the factor of safety (FOS), using the Mohr-Coulomb stress criterion. The Mohr-Coulomb stress criterion enables the prediction of the occurrence of failures when the connection of the maximum tensile principal stress σ1 and the minimum compressive principal stress σ3 exceed relevant stress limits. The criterion is used for materials which indicates distinct tensile and compressive characteristics. The numerical method presented in the paper can be utilized in evaluating the mining natural hazards through predicting the parameters, which determine the roof maintenance in the longwall working.

One of the purposes of the numerical analysis was to draw attention to the possibilities that are currently created by specialized software as an important element accompanying the modern design process, which forms part of intelligent underground mining 4.0.

Go to article

Authors and Affiliations

Tomasz Janoszek
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

An uniaxial compression mechanical model for the roof rock-coal (RRC) composite sample was established in order to study the effects of height ratio of roof rock to coal on the structural strength of composite sample. The composite sample strengths under different height ratios were established through stress and strain analysis of the sample extracted from the interface. The coal strength near the interface is enhanced and rock strength near the interface weakened. The structural strength of composite sample is synthetically determined by the strengths of rock and coal near and far away from the interface. The area with a low strength in composite sample is destroyed firstly. An analytical model was proposed and discussed by conducting uniaxial compression tests for sandstone-coal composite samples with different height ratios, and it was found that the structural strength and elastic modulus decrease with a decrease in height ratio. The coal strengths far away from the interface determine the structural strengths of composite sample under different height ratios, which are the main control factor for the structural strength in this test. Due to its lowest strength, the rock near the interface first experienced a tensile spalling failure at the height ratio of 9:1, without causing the structural failure of composite sample. The coal failure induces the final failure of composite sample.

Go to article

Authors and Affiliations

Dawei Yin
Shaojie Chen
Xizhen Sun
Ning Jiang
Download PDF Download RIS Download Bibtex

Abstract

Green roofs are increasingly popular in both new and modernised buildings. They significantly reduce the outflow of stormwater from buildings and change its composition. Wherever an urbanised area is equipped with a separate sewage system, usually stormwater goes directly to the receiver without treatment, which may affect the quality of water in the receiver. The article presents results of research carried out on the green roof of a building in Lodz, Poland. During rainfall, the flow rate from the roof was measured. With the use of the US EPA software Stormwater Management Model (SWMM) a model of the green roof was created and calibrated using rainfall data from the city’s pluviometric network. Based on the measurements of the roof runoff, as well as SWMM modelling, the degree of outfall reduction was determined. Samples of roof runoff were collected to study the characteristics of rainwater, including pH, electrical conductivity, organic compounds, nitrogen, phosphorus, and suspended solids. The results were compared with the quality of runoff from a traditional roof. Except ammonium nitrogen, values of the examined quality indicators was higher in the case of the green roof but the pollution load of almost all contaminants, except phosphorus, were lower due to a significant reduction in the volume of stormwater outflow (62–91%). The quality of stormwater discharged from the green roof improved with its age.
Go to article

Authors and Affiliations

Grażyna Sakson
1
ORCID: ORCID

  1. Lodz University of Technology, Institute of Environmental Engineering and Building Installations, Al. Politechniki 6, 90-924, Łódź, Poland
Download PDF Download RIS Download Bibtex

Abstract

Access to clean and sufficient drinking water is difficult in much of Ethiopia’s Afar Region. It is observed that many schemes in the region are non-functional. The study was conducted to overcome the observed problem in seven selected districts of the region. The study regarded hand-dug wells and roof water collection systems, which are the two most common features in the research areas. Eight hand-dug wells and sixteen roof water harvestings are purposively included in the study. All the water points are constructed by Kelem Ethiopia which is a non-governmental organisation and the foremost local organisation for the communities. As per the research survey, the average functional status of the hand-dug well schemes is 65.75% and the roof water harvesting schemes is 22.94%. The research was based on the qualitative data collected on site. The hand-dug well sites were evaluated using 10 parameters, and the roof water harvesting schemes were analysed using 12 parameters. The main non-functional aspects of the scheme are lack of community ownership, drying up of water sources, lack of maintenance and rehabilitation, poor coordination of beneficiaries and school roofs blowing off. Most schemes still require minor to major maintenance and rehabilitation. According to the research, the solutions for water supply are identified in relation to the desired objective.
Go to article

Authors and Affiliations

Melese C. Shumie
1

  1. Debre Berhan University, Department of Civil Engineering, Debre Berhan, PO Box 445, Ethiopia
Download PDF Download RIS Download Bibtex

Abstract

The most important challenges in the construction field is to do the experimentation of the designing at real time. It leads to the wastage of the materials and time consuming process. In this paper, an artificial neural network based model for the verification of sigma section characteristics like shear centre and deflection are designed and verified. The physical properties like weight, depth, flange, lip, outer web, thickness, and area to bring shear centre are used in the model. Similarly, weight, purlin centres with allowable loading of different values used in the model for deflection verification. The overall average error rate as 1.278 percent to the shear centre and 2.967 percent to the deflection are achieved by the model successfully. The proposed model will act as supportive tool to the steel roof constructors, engineers, and designers who are involved in construction as well as in the section fabricators industry.

Go to article

Authors and Affiliations

S. Janani
R. Thenmozhi
L.S. Jayagopal
Download PDF Download RIS Download Bibtex

Abstract

Types of wind storms in Poland and examples of economic damage, threats to human life and health caused by two extreme wind events are presented. Then, a house with the roof blown-off during the derecho wind storm in Poland on August 11-12, 2017, is considered. Based on the rafter framing of the house, i.e. wooden roof structure elements and roof covered, the weight of the roof is calculated. Two cases of the strong connection between rafter plates and knee walls are estimated. With the estimation of connection strength between rafter plates and knee walls, it was possible to calculate the total force required to blow-off the roof of the house. Next, an aerodynamic force acting on the house is calculated using pressure coefficients for a low-rise house with a gable roof. The pressure coefficients were taken from the Tokyo Polytechnic University aerodynamic database. The aerodynamic force acting on the roof blown-off was calculated for a low-rise building with a gable roof for similar ratios for length, width, and height. Three wind directions, for the unknown orientation of the building, were considered, i.e. the wind direction perpendicular, parallel, and oblique to the gable wall. By comparison, the aerodynamic force with the total force required to blow-off the roof of the house, it was possible to calculate the critical wind speed needed for the roof blown-off. This wind speed is much bigger than measured by meteorological stations on the path of the derecho.

Go to article

Authors and Affiliations

Tadeusz Chmielewski
Barbara Kaleta
Henryk Nowak
Download PDF Download RIS Download Bibtex

Abstract

Application of retractable enclosures enables to lengthen operation periods for outdoor swimming pools operated in the moderate climate zone. Enclosures allow to diminish energy losses from water in the pool to the environment. Thermal calculations for pools with retractable enclosures are difficult to carry out because of a number of required parameters which can only be estimated. One of them is the transmission of solar radiation through the enclosure. The present paper presents the method of estimation of this parameter for swimming pool enclosures made of polycarbonate panels that have multichannels structure. In order to calculate transmission, the methodology considering the multiples of solar reflection inside the enclosure and their absorption by polycarbonate has been elaborated. Calculation results for transmission of the enclosure were verified experimentally. Analysis of results show that the transmission depends strongly on the enclosure’s construction and on the direction of solar radiation on the enclosure. Mean transmission values of enclosure under research were determined both from calculations and experiment are equal to about 0.69 and 0.64, respectively. However, experimentally determined mean values of total transmission by parallel and perpendicular solar directions in relation to channel axes are equal to about 0.69 and 0.60, respectively.
Go to article

Bibliography

[1] Buonomano A., De Luca G., Figaj R.D., Vanoli L.: Dynamic simulation and thermo-economic analysis of a PhotoVoltaic/Thermal collector heating system for an indoor-outdoor swimming pool. Energ. Convers. Manage. 99(2015), 176–192.
[2] Chwieduk D.: Solar Energy of Building. Arkady, Warszawa 2011 (in Polish).
[3] Garnysz A., Zapałowicz Z.: Model of heat and mass transfer in swimming pool with roofing system. In: Proc. XX Int. Tagung “Forschung – Praxis – Didaktik im modernen Maschinenbau”. Stralsund, 21–24 Sept. 2011.
[4] Garnysz A., Zapałowicz Z.: Thermal calculations for swimming pool with the roofing system. In: Proc. 3rd Int. Conf. Low Temperature and Waste Heat Use in Energy Supply Systems – Theory and Practice. Bremen, 25–26 Oct. 2012, 72–78.
[5] Garnysz A., Zapałowicz Z.: Model of heat and mass transfer in swimming pools with roofing systems. Developments in Mechanical Engineering Vol. 5 (J.T. Cieslinski, J. Szymczak, Eds.), Gdansk University of Technology Publishers, Gdansk 2012, 49–58.
[6] Garnysz A., Zapałowicz Z.: Influence of environmental conditions on selected thermal parameters for the swimming pool with movable enclosure. Zeszyty Naukowe Politechniki Rzeszowskiej 290, Mechanika, RUTMech XXXI, 86(2014), 2/14, 207– 214 (in Polish).
[7] Garnysz A., Zapałowicz Z.: Comparison of characteristic thermal parameters for a swimming pool with retractable pool enclosures exploited in autumn and spring seasons. In: Proc. XV Int. Conf. on Heat Transfer and Renewable Sources of Energy (A.A. Stachel, D. Mikielewicz, Eds.), Wydawnictwo Uczelniane ZUT, Szczecin 2014, 301–306.
[8] Garnysz A.: Experimental study of thermal parameters for the swimming pool with movable transparent enclosure. Instal 1(2014), 33–36 (in Polish).
[9] Govaer D., Zarmi Y.: Analytical evaluation of direct solar heating of swimming pools. Sol. Energy 27(1981), 6, 529–533.
[10] Grudzinska M.: Mathematical models of solar transmission through transparent insulation. Fizyka budowli w teorii i praktyce VI(2011), 4, 21–26 (in Polish).
[11] http://energy.gov/energysaver/articles/swimming-pool-covers (accessed: July 2019).
[12] http://libart.com/ (accessed: 7 July 2019).
[13] http://www.alutherm.com.pl/ (accessed: 7 July 2019) (in Polish).
[14] http://www.aquashield.com (accessed: 7 July 2019).
[15] http://www.telescopicpoolenclosures.com (accessed: 7 July 2019).
[16] Katsaprakakis D.A.: Comparison of swimming pools alternative passive and active heating systems based on renewable energy sources in Southern Europe. Energy 81(2015), 738–753.
[17] Mousia A., Dimoudi A.: Energy performance of open air swimming pools in Greece. Energ. Buildings 90(2015), 166–172.
[18] Pluta Z.: Theoretical Basis of Photothermal Solar Energy Conversion. Oficyna Wydawnicza Politechniki Warszawskiej, Warszawa 2006 (in Polish).
[19] Desirable pool. E-fachowiec (2010), 3. http://www.efachowiec.info/ (accessed: 7 July 2019) (in Polish).
[20] Swimming pool covers, rolling devices and roofing. AstralPool catalog. http://www.astralpool.pl/dokumenty/331–362.pdf (accessed: 7 July 2019) (in Polish).
[21] Specialists in design, planning and build of aluminium, timber and PVCu pool enclosures. https://www.telescopicpoolenclosures.com/images/telescopic-poolenclosures- brochure.pdf (accessed: 7 July 2019).
[22] Pool technology. 2014/15. Basenhurt’s catalog. http://www.basenhurt.pl/katalog 2014/KatalogBasenHurt2014_15.pdf (accessed: 6 June 2015).
[23] EN 16153:2013+A1:2015 Light transmitting flat multiwall polycarbonate (PC) sheets for internal and external use in roofs, walls and ceilings. Requirements and test methods.
[24] ITB: Technical Assessment ITB AT-15-8917/2012. Płyty komorowe z poliweglanu Lexan Thermoclear LT2UV: 62RS, 82 RS, 102 RS, 105 RS, 163TS, 166RS, 165X, 169X, 206RS, 205X, 209X, 256RS, 255X, 259X, 253X and 325X, Warszawa 2013, ISBN 978-83-249-6236-8 (in Polish).
[25] Lexan Thermoclear: Polycarbonate cellular panels. Technical documentation . Sabic 02.2014 (in Polish).
Go to article

Authors and Affiliations

Zbigniew Zapałowicz
1
Agnieszka Garnysz-Rachtan
1

  1. West Pomeranian University of Technology in Szczecin, Faculty of Mechanical Engineering and Mechatronics, Department of Energy Technologies, Al. Piastów 19, 70-310 Szczecin, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper concerns a numerical analysis of cooling of the hybrid photovoltaic (PV) modules dedicated to Building-Inte-grated Photovoltaic/Thermal (BIPV/T) systems. Attention was focused on the photovoltaic roof tiles, using a jet impinge-ment technique, in which the intensification of heat transfer is ensured by streams of air hitting the heat exchange partition. A series of numerical simulations were carried out to assess an influence of the distance of the nozzle outlet from the absorber surface on the values of selected thermal-hydraulic performance indicators and the electrical parameters of the roof tile. The results confirmed the high effectiveness of the proposed method. The best effect was obtained for the case in which the relative distance of the nozzle from the partition to the nozzle diameter was equal to 1. For the mentioned configuration, an over 4 times increase in the value of the heat transfer coefficient was obtained in relation to the reference variant of cooling roof tiles. At the same time, the relative increase in the value of the generated electrical power was from 2.9 to 7.8%, depending on the value of the Reynolds number characterising the flow.
Go to article

Authors and Affiliations

Jan Wajs
1
Jakub Lukasik
1

  1. Faculty of Mechanical Engineering and Ship Technology, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper analyses the loss mechanism of roof insulation kits’ performance due to dampness increase in the insulation layers. The analyzed structures were used in standard conditions for ten years and had thermal insulation made of expanded polystyrene with a hydrophobized surface. The dampness of the thermal insulation materials was determined after the referenced period for their future fitness as roof insulation, based on laboratory tests of material samples collected from the structures. They were completed with a computer simulation of heat transfer and dampness in the partition for working conditions specified for ten years, assuming the thermal conductivity was determined for the materials collected from the analyzed roofs. It was discovered that simulation-based calculation dampness values are much lower than those observed after ten years of roof utilization. Additionally, the authors attempted to determine the correlations between the period of thermal insulation materials used in real conditions and the selected properties of the products determined in laboratory tests. To that end, the collected material was dried to constant weight and then subjected to accelerated aging through total immersion in water at room temperature, for twenty-eight days, followed by 300 freeze-thaw cycles at –20°C and +20°C. The results helped conclude that the abovementioned laboratory testing cycle does not allow for assessing the fitness for the use of the referenced products for ten years. The directions of future laboratory tests were set, suggesting extending the testing cycle at least twice.
Go to article

Authors and Affiliations

Barbara Francke
1
ORCID: ORCID
Agnieszka Winkler-Skalna
2
ORCID: ORCID
Robert Geryło
3
ORCID: ORCID

  1. Warsaw University of Life Sciences – SGGW, Institute of Civil Engineering, Nowoursynowska 159, 02-776 Warsaw, Poland
  2. Thermal Physics, Acoustics and Environment Department, Building Research Institute, Filtrowa 1,00-611 Warsaw, Poland
  3. Building Research Institute, Filtrowa 1, 00-611 Warsaw, Poland

This page uses 'cookies'. Learn more