Author explains a necessity of supply optimization to construction sites with small storage areas. This paper takes account of conditions existing in Poland. From among all factors discussed by the author, first of all, we should point at construction works on plots located in densely built-up areas, obtained by demolition of existing buildings, as well as a necessity of plots utilization after demolished buildings that technical conditions do not allow for further exploitation.
Chemical industries in Onitsha urban area of southeastern Nigeria have been discharging large quantities of effluents into surface streams. These streams are the primary sources of water used by poor households for domestic purposes. This study examines the effects of effluents on the physicochemical and microbiological characteristics of the recipient streams. This objective was achieved by collecting eight effluents and twenty-two water samples from control points, discharge lo-cations and exit chutes of the effluents for analysis. The results of the study characterised the effluents and their effects on the recipient streams. The effluents cause gross pollution of the streams as most of the parameters including pH, total dis-solved solids (TDS), turbidity, biological oxygen demand (BOD), chemical oxygen demand (COD), Mg, NO3, Fe, Cu, Pb, Cr, total heterotrophic count (THC) and total coliform group (TCG) returned high values that exceeded the World Health Organisation’s (WHO) benchmark from 2011 for drinking water quality. Only dissolved oxygen (DO), Na, Zn, Ca, and Na returned values lower than the WHO guideline. E. coli was found in all the samples; TCG was also high. This paper, there-fore, recommends that the effluent generating industries should treat their effluents before disposal.
The text comprises the evaluation of relationship between the qualitative planning tools and the Irish housing policy in the pre-crisis period, during the crisis (2009-2013) and the recovery. The tools that affect housing are understood as spatial planning, including governmental regulations on densification of the development and the housing quality as well as the special tools such as the urban design. Those regulatory tools were deployed with aims to safeguard the sustainable and socially viable housing structures. The Irish case illustrates the considerable innovation in introducing new housing standards and challenges with their efficiency. This can be attributed to the lack of integration with other elements that shaped the market – financing and actions of the private market, low efficiency of planning or the lack of the scale effect for the model developments. Despite their drawbacks these tools are continuously being used, as their foundational principles are still valid.
In this paper, selected aspects of the national technical level of electric energy supply security is shown. An analysis and assessment of the electric power infrastructure in area of generation, transmission and distribution in aspects of electric energy security is conducted. The profile of the generation sector and grid infrastructure in the area of transmission and distribution is shown. The present and future situation in a range of operation of electric power infrastructure in the area of generation, transmission and distribution in the frames of the National Electric Power System in the electric energy supply security context is determined. The level of national electric energy supply security in area of generation and grid infrastructure is assessed. Threats of electric energy supply security are described and the catalogue of essential actions for the assurance of electric energy supply security are proposed. In the area of electricity generation, at present there is no danger to the electricity supply security in normal load conditions, but there is a high probability that it will occur in the future (after 2025) when the forecasted increase in electricity demand takes place and the new stringent environment protection requirements (Directive IED, BAT conclusions, Winter Package) enter into force. The network infrastructure in area of transmission and distribution is admittedly adapted for presently occurred typical conditions of electric energy demand and the realization of internal tasks in normal conditions, but can create a potential threat for electric energy supply security. In the context of the forecasted increase of electric energy demand, inadequate power generation sources in the National Electric Power System and available through intersystem connections, their uneven location on the territory of Poland in the shortage of proper network transmission capacities, the necessity of improvement of the quality and electric energy supply reliability to final consumers and the intensive development of renewable energy sources, the present network infrastructure in area of transmission and distribution will be insufficient.
The Stirling engine type alpha is composed of two cylinders (expansion space E and compression space C), regenerator that forms the space between the cylinders and the buffer space (under the pistons). Before the start-up and as a result of long-term operation, the average pressure in the working space (above the pistons) and in the buffer space is the same. However, in the initial phase of operation, the average pressure in the working space is different then the average pressure in the buffer space depending on the crankshaft starting position (starting angle). This, in turn, causes a large variation in the starting torque. An additional unfavorable factor caused by a large variation in the course of the indicated torque is the rotational speed variation and the formation of torsional vibrations in the drive system. After some time, depending on the quality of the engine piston sealing, the average pressure in the working and buffer space will equalize. The occurrence of the above-described phenomenon affects the selection of the starting electric motor, which can be significantly reduced, when the crankshaft starting position is optimized (the starting torque is several times greater than the average torque occurring in the generator operation mode). This paper presents the analysis of the impact of the crankshaft starting position on the course of the indicated torque and the resulting start-up energy. Starting the engine at an unfavorable position of the crankshaft may, in extreme cases, increase the starting torque even three times.
In view of the world’s recent changes in the mineral market, it is becoming increasingly important to ensure the sustainable and secure supply of raw materials, both within the European Union and in other high-developed countries. In response to this global challenge, as part of the European Commission’s Horizon 2020 Program for Research & Innovation, the 36-month INTRAW project was launched in February 2015 to foster international cooperation on raw materials. The EU-funded INTRAW project was set up to map and develop new cooperation opportunities related to raw materials between the EU and other technologically advanced countries, such as: Australia, Canada, Japan, South Africa and the United States. The first stage of the project was a review of conditions for the stable supply of raw materials from primary and secondary sources in selected countries: the United States, Canada, Australia, South Africa and Japan. The results of the work are two groups of comprehensive reports. The first of these is a broad contextual analysis of geological, environmental, political, technical -economic and social factors conducive to the effective management of mineral resources. The second group is operational reports, carried out in three thematic blocks: industry and trade, research and innovation, education. The analysis clearly shows that the basis for effective action in this area is a stable political, economic and institutional environment, which is friendly to mining and new entities wishing to invest in modern technologies, the exploration and exploitation of deposits. Investors are encouraged by tax regulations, sometimes also by direct government financial support and efficient licensing procedures. The well-defined protection of property rights, also for deposits is equally important. Selected aspects of a wide analysis of determinants of competitiveness for these countries were presented in the article below.
In order to improve the efficiency and ensure the security of power supply used in a mine, this paper mainly studies the quasi-resonant flyback secondary power supply and analyzes its operational principles based on the requirements of soft-switching technology. In accordance with the maximum energy of a short-circuit and the request of maximum output voltage ripple, this paper calculates the spectrum value of the output filter capacitor and provides its design and procedures to determine the parameters of the main circuit of power supply. The correctness and availability of this theory are eventually validated by experiments.
In the hybrid multiple H-bridge topology of beam supply, the load change of a DC/DC full-bridge converter can greatly affect the output voltage during onsite operation. An improved sliding mode control (SMC) strategy is thus proposed in this paper, where the rate of switching control is added to the law of system equivalent control to create a law that can realize a complete sliding mode control. Considering the special operating conditions of the load can have an influence on the performance of the controller, the impact of uncertainty existing in onsite conditions is suppressed with the proposed strategy utilized. The validity of the proposed strategy, finally, is verified by simulation, which proves the outperformance of the system in both robustness and dynamics.
This paper presents an innovative solution for increasing life of lead-acid batteries used in a glider launcher. The study is focused on upgrading a charging system instead of a costly full replacement of it. Based on literature review, the advanced three-stage charging profile was indicated. The new topology of the power converter was proposed and a simulation model was developed. A simulation study was performed which leads to a conclusion that the suggested solution can be successfully applied to the studied device. As a result, the conclusion of this work is the recommendation for modification of the launching system with an additional converter enabling 3 stage charging.
Assessment of the state of a pulse power supply requires effective and accurate methods to measure and reconstruct the tracking error. This paper proposes a tracking error measurement method for a digital pulse power supply. A de-noising algorithm based on Empirical Mode Decomposition (EMD) is used to analyse the energy of each Intrinsic Mode Function (IMF) component, identify the turning point of energy, and reconstruct the signal to obtain the accurate tracking error. The effectiveness of this EMD method is demonstrated by simulation and actual measurement. Simulation was used to compare the performance of time domain filtering, wavelet threshold de-noising, and the EMD de-noising algorithm. In practical use, the feedback of current on the prototype of the power supply is sampled and analysed as experimental data.
The work presents a DC power supply with power factor correction (PFC). This device is also equipped with a parallel active filter function, which enables the possibility of compensation (minimization) of reactive and distortion power, generated by a group of loads, connected to the same power grid node. A passive filter with variable inductance applied at the input of the power supply allows for a significant improvement in quality of the system control (given specific criteria), as compared to the solution with a filter with fixed parameters. This is possible by increasing the dynamics of current changes at the power supply input (extending its “frequency response”). The paper presents the principle of operation as well as structures and models of the power supply control system and its power stage. Selected test results of the simulation model of the electric system with the power supply, in various operating conditions, are also presented.