Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 10
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

In model predictive control (MPC), methods of linear offset free MPC are well established such as the disturbance model, the observer method and the state disturbance observer method. However, the observer gain in those methods is difficult to define. Based on the drawbacks observed in those methods, a novel algorithm is proposed to guarantee offset-free MPC under model-plant mismatches and disturbances by combining the two proposed methods which are the proposed Recursive Kalman estimated state method and the proposed Disturbance-Kalman state method. A comparison is made from existing methods to assess the ability of providing offset-free MPC onWood-Berry distillation column. Results shows that the proposed offset free MPC algorithm has better disturbance rejection performance than the existing algorithms.
Go to article

Authors and Affiliations

Truong Thanh Tuan
1
Haslinda Zabiri
2
Mohammad Ibrahim Abdul Mutalib
2
Dai-Viet N. No
3

  1. Petrovietnam University, 762 Cach Mang Thang Tam Street, Long Toan Ward, Ba Ria City 78109, Ba Ria Vung Tau Province, Vietnam
  2. Department of Chemical Engineering, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 32610 Tronoh, Perak, Malaysia
  3. Center of Excellence for Green Energy and Environmental Nanomaterials (CE@GrEEN), Nguyen Tat Thanh University, 300A Nguyen Tat Thanh, District 4, Ho Chi Minh City755414, Viet Nam
Download PDF Download RIS Download Bibtex

Abstract

The model predictive current control (MPCC) of the permanent magnet synchronous motor (PMSM) is highly dependent on motor parameters, and a parameter mismatch will cause the system performance degradation. Therefore, a strategy based on an internal model control (IMC) observer is proposed to correct the mismatch parameters. Firstly, based on the MPCC strategy of the PMSM, according to the dynamic model of the PMSM in a rotating orthogonal coordinate system, d-axis and q-axis current IMC observers are designed, and the stability derivation is carried out. It is proved that the observer can estimate d-axis and q-axis disturbance components caused by a parameter mismatch without static error. Then, the estimated disturbance component is compensated for by the reference voltage prediction expression. Finally, the effectiveness of the proposed strategy is verified in two different conditions. The experimental results show that the proposed control strategy can effectively compensate for the parameter mismatch disturbance in MPCC for PMSM, improve the dynamic and static performance of the system, and improve the robustness of the system.
Go to article

Authors and Affiliations

Min'an Tang
1
Chenyu Wang
1
Yinhang Luo
1
ORCID: ORCID

  1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, China No. 88, Anning West Road, Anning District, Lanzhou City, Gansu Province, China
Download PDF Download RIS Download Bibtex

Abstract

One of the main problems of multivariable cost functions in model predictive control is the choice of weighting factors. Two finite control set model predictive control algorithms, applied to the three-phase active rectifier with an LCL filter, are described in the paper. The investigated algorithms, i.e. PCicuc and PCigicuc, implement multivariable approaches applying line (grid) current, capacitor voltage and converter current. The main problem dealt with in the paper is the choice of optimum values of the cost function weighting factors. The values of the factors calculated using the method proposed in the paper are very close to the values represented by the lowest THDi of the line current. Moreover, simulations verifying the equations used in the prediction of controlled values, i.e. line current, capacitor voltage and converter current, are presented. Both simulation and experimental results are presented to verify effectiveness of the investigated control strategies under change of the load (P = 5 kW and 2.5 kW), during transient states, under unbalanced and balanced line voltage.

Go to article

Authors and Affiliations

P. Falkowski
A. Sikorski
K. Kulikowski
M. Korzeniewski
Download PDF Download RIS Download Bibtex

Abstract

Maritime Autonomous Surface Ships (MASS) perfectly fit into the future vision of merchant fleet. MASS autonomous navigation system combines automatic trajectory tracking and supervisor safe trajectory generation subsystems. Automatic trajectory tracking method, using line-of-sight (LOS) reference course generation algorithm, is combined with model predictive control (MPC). Algorithm for MASS trajectory tracking, including cooperation with the dynamic system of safe trajectory generation is described. It allows for better ship control with steady state cross-track error limitation to the ship hull breadth and limited overshoot after turns. In real MASS ships path is defined as set of straight line segments, so transition between trajectory sections when passing waypoint is unavoidable. In the proposed control algorithm LOS trajectory reference course is mapped to the rotational speed reference value, which is dynamically constrained in MPC controller due to dynamically changing reference trajectory in real MASS system. Also maneuver path advance dependent on the path tangential angle difference, to ensure trajectory tracking for turns from 0 to 90 degrees, without overshoot is used. All results were obtained with the use of training ship in real–time conditions.
Go to article

Authors and Affiliations

Anna Miller
1
ORCID: ORCID

  1. Gdynia Maritime University, ul. Morska 81-87, 81-225 Gdynia, Poland
Download PDF Download RIS Download Bibtex

Abstract

In the finite control set model predictive control (FCS-MPC) strategy of the grid-tied inverter, the current ripple (CR) affects the selection of optimal voltage vectors, which leads to the increase of output current ripples. In order to solve this problem, this paper proposes a CR reduction method based on reference current compensation (RCC) for the FCS-MPC strategy of grid-tied inverters. Firstly, the influence of the CR on optimal voltage vector selection is analyzed. The conventional CR prediction method is improved, which uses inverter output voltage and grid voltage to calculate current ripples based on the space state equation. It makes up for the shortcomings that the conventional CR prediction method cannot predict in some switching states. The improved CR method is more suitable for the FCS-MPC strategy. In addition, the differences between the two cost functions are compared through visual analysis. It is found that the sensitivity of the square cost function to small errors is better than that of the absolute value function. Finally, the predicted CR is used to compensate the reference current. The compensated reference current is substituted into the square cost function to reduce the CR. The experimental results show that the proposed method reduces the CR by 47.3%. The total harmonic distortion (THD) of output current is reduced from 3.86% to 2.96%.
Go to article

Authors and Affiliations

Nan Jin
1
ORCID: ORCID
Wuchuang Fan
1
Jie Fang
1
Jie Wu
1
Yongpeng Shen
1

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a novel model predictive flux control (MPFC) scheme for three-level inverter-fed sensorless induction motor drive operated in a wide speed region, including field weakening. The novelty of the proposed drive lies in combining in one system a number of new solutions providing important features, among which are: very high dynamics, constant switching frequency, no need to adjust weighting factors in the predictive cost function, adaptive speed and parameter (stator resistance, main inductance) estimation. The theoretical principles of the optimal switching sequence predictive stator flux control (OSS-MPFC) method used are also discussed. The method guarantees constant switching frequency operation of a three-level inverter. For speed estimation, a compensated model reference adaptive system (C-MRAS) was adopted while for IM parameters estimation a Q-MRAS was developed. Simulation and experimental results measured on a 50 kW drive that illustrates operation and performances of the system are presented. The proposed novel solution of a predictive controlled IM drive presents an attractive and complete algorithm/system which only requires the knowledge of nominal IM parameters for proper operation.

Go to article

Authors and Affiliations

D. Stando
M.P. Kazmierkowski
Download PDF Download RIS Download Bibtex

Abstract

High-frequency resonance is a prominent phenomenon which affects the normal operation of the high-speed railway in China. Aiming at this problem, the resonance mechanism is analyzed first. Then, model predictive control and selective harmonic elimination pulse-width modulation (MPC-SHEPWM) combined control strategy is proposed, where the harmonics which cause the resonance can be eliminated at the harmonic source. Besides, the MPC is combined to make the current track the reference in transients. The proposed control has the ability to suppress the resonance while has a faster dynamic performance comparing with SHEPWM. Finally, the proposed MPC-SHEPWM is tested in a simulation model of CRH5 (Chinese Railway High-speed), EMUs (electric multiple units) and a traction power supply coupled system, which shows that the proposed MPC-SHEPWM approach can achieve the resonance suppression and shows a better dynamic performance.
Go to article

Bibliography

[1] Mollerstedt E., Bernhardsson B., Out of control because of harmonics-an analysis of the harmonic response of an inverter locomotive, IEEE Control Systems Magazine, vol. 20, no. 4, pp. 70–81 (2000).
[2] Sainz L., Caro M., Caro E., Analytical Study of the Series Resonance in Power Systems With the Steinmetz Circuit, IEEE Transactions on Power Delivery, vol. 24, no. 4, pp. 2090–2098 (2009).
[3] Lee H., Lee C., Jang G., Kwon S., Harmonic analysis of the korean high-speed railway using the eight-port representation model, IEEE Transactions on Power Delivery, vol. 21, no. 2, pp. 979–986 (2006).
[4] Holtz J., Kelin H., The propagation of harmonic currents generated by inverter-fed locomotives in the distributed overhead supply system, IEEE Transactions on Power Electronics, vol. 4, no. 2, pp. 168–174 (1989).
[5] Chang G.W., Lin H.W., Chen S.K., Modeling characteristics of harmonic currents generated by highspeed railway traction drive converters, IEEE Trans. Power Delivery, vol. 19, no. 2, pp. 766–773 (2004).
[6] Hu H., Shao Y., Tang L., Ma J., He Z., Gao S., Overview of Harmonic and Resonance in Railway Electrification Systems, IEEE Transactions on Industry Applications, vol. 54, no. 5, pp. 5227–5245 (2018).
[7] Kolar V., Palecek J., Kocman S. et al., Interference between electric traction supply network and distribution power network - resonance phenomenon, International Conference on Harmonics and Quality of Power, Bergamo, Italy (2010).
[8] Brenna M. et al., Investigation of resonance phenomena in high speed railway supply systems: Theoretical and experimental analysis, Elect. Power Syst. Res., vol. 81, no. 10, pp. 1915–1923 (2011).
[9] Hu H., Gao S., Shao Y., Wang K., He Z., Chen L., Harmonic Resonance Evaluation for Hub Traction Substation Consisting of Multiple High-Speed Railways, IEEE Transactions on Power Delivery, vol. 32, no. 2, pp. 910–920 (2017).
[10] Li J.,Wu M., Molinas M., Song K., Liu Q., Assessing High-Order Harmonic Resonance in Locomotive- Network Based on the Impedance Method, IEEE Access, vol. 7, pp. 68119–68131 (2019).
[11] Hu H., Tao H., Blaabjerg F., Wang X., He Z., Gao S., Train–Network Interactions and Stability Evaluation in High-Speed Railways–Part I: Phenomena and Modeling, IEEE Transactions on Power Electronics, vol. 33, no. 6, pp. 4627–4642 (2018).
[12] Lee H., Kim G., Oh S., Lee C., Optimal design for power quality of electric railway, SICE-ICASE International Joint Conf., Busan, Korea, pp. 3864–3869 (2006).
[13] Hu H., He Z., Gao S., Passive Filter Design for China High-Speed RailwayWith Considering Harmonic Resonance and Characteristic Harmonics, IEEE Transactions on Power Delivery, vol. 30, no. 1, pp. 505–514 (2015).
[14] Zhang X., Chen J., Zhang G., Wang L., Qiu R., Liu Z., An Active Oscillation Compensation Method to Mitigate High-Frequency Harmonic Instability and Low-Frequency Oscillation in Railway Traction Power Supply System, IEEE Access, vol. 6, pp. 70359–70367 (2018).
[15] Holtz J., Krah J.O., Suppression of time-varying resonances in the power supply line of AC locomotives by inverter control, IEEE Transactions on Industrial Electronics, vol. 39, no. 3, pp. 223–229 (1992).
[16] Zhang Y., Xiong J., Kong L., Wang X., A novel in-phase disposition SPWM pulse allocation strategy for cascaded H-bridge inverter, Archives of Electrical Engineering, vol. 67, no. 2, pp. 361–375 (2018).
[17] Cui H., Song W., Fang H., Ge X., Feng X., Resonant harmonic elimination pulse width modulationbased high-frequency resonance suppression of high-speed railways, IET Power Electronics, vol. 8, no. 5, pp. 735–742 (2015).
[18] Song K., Konstantinou G., MingliW., Acuna P., Aguilera R.P., Agelidis V.G.,Windowed SHE–PWM of Interleaved Four-Quadrant Converters for Resonance Suppression in Traction Power Supply Systems, IEEE Transactions on Power Electronics, vol. 32, no. 10, pp. 7870–7881 (2017).
[19] Dahidah M.S.A., Konstantinou G., Agelidis V.G., A Review of Multilevel Selective Harmonic Elimination PWM: Formulations, Solving Algorithms, Implementation and Applications, IEEE Transactions on Power Electronics, vol. 30, no. 8, pp. 4091–4106 (2015).
[20] Rodriguez J. et al., Predictive control of three-phase inverter, Electronics Letters, vol. 40, no. 9, pp. 561–563 (2004).
[21] Aguilera R.P. et al., Selective Harmonic Elimination Model Predictive Control for Multilevel Power Converters, IEEE Transactions on Power Electronics, vol. 32, no. 3, pp. 2416–2426 (2017).
[22] Cui H., Feng X., SongW., Modeling of high-order harmonic load for high-speed train, Electr. Power Equip. Autom., vol. 33, no. 7, pp. 92–99 (2013).
[23] Dolara A., Gualdoni M., Leva S., Impact of high-voltage primary supply lines in the 2 x 25 kV 50 Hz railway system on the equivalent impedance at pantograph terminals, IEEE Transactions on Power Delivery, vol. 27, no. 1, pp. 164–175 (2012).
[24] Dahidah M.S.A., Konstantinou G., Agelidis V.G., A Review of Multilevel Selective Harmonic Elimination PWM: Formulations, Solving Algorithms, Implementation and Applications, IEEE Transactions on Power Electronics, vol. 30, no. 8, pp. 4091–4106 (2015).
[25] Liang T.J., Hoft R.G., Walsh function method of harmonic elimination, Proc. IEEE Appl. Power Electron. Conf., San Diego, CA, USA, Mar. 7–11, pp. 847–853 (1993).
[26] Yang K., Yuan Z., Yuan R., YuW., Yuan J.,Wang J., A Groebner Bases Theory-Based Method for Selective Harmonic Elimination, IEEE Transactions on Power Electronics, vol. 30, no. 12, pp. 6581–6592 (2015).
[27] Kavitha R., Thottungal Rani, WHTD missisation in hybird multilvel inverter biogeographcial based Optimisation, Archives of Electrical Engineering, vol. 63, no. 2, pp. 187–196 (2014).
[28] Rodriguez J. et al., State of the Art of Finite Control Set Model Predictive Control in Power Electronics, IEEE Transactions on Industrial Informatics, vol. 9, no. 2, pp. 1003–1016 (2013).

Go to article

Authors and Affiliations

Sitong Chen
1
ORCID: ORCID
Xiaoqiang Chen
1
Ying Wang
1
ORCID: ORCID
Ye Xiong
1

  1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
Download PDF Download RIS Download Bibtex

Abstract

Most of the basic control methods of the grid-connected converter (GCC) are defined to work with a sine wave grid voltage. In that case if the grid voltage is distorted by higher harmonics, the grid current may be distorted too, which, in consequence, may increase the value of the THD of the grid voltage. The paper deals with an improved finite control set model predictive control (FCS-MPC) method of an LCL-filtered GCC operating under distorted grid conditions. The proposed method utilizes supplementary grid current feedback to calculate the reference converter current. The introduced signal allows to effectively improve the operation when the grid is subject to harmonic distortion. The paper shows a simulation analysis of the proposed control scheme operating with and without additional feedback under grid distortions. To validate the practical feasibility of the proposed method an algorithm was implemented on a 32-bit microcontroller STM32F7 with a floating point unit to control a 10 kW GCC. The laboratory test setup provided experimental results showing properties of the introduced control scheme.

Go to article

Authors and Affiliations

P. Falkowski
A. Godlewska

This page uses 'cookies'. Learn more