The present study examines some durability aspects of ambient cured bottom ash geopolymer concrete (BA GPC) due to accelerated corrosion, sorptivity, and water absorption. The bottom ash geopolymer concrete was prepared with sodium based alkaline activators under ambient curing temperatures. The sodium hydroxide used concentration was 8M. The performance of BA GPC was compared with conventional concrete. The test results indicate that BA GPC developes a strong passive layer against chloride ion diffusion and provides better protection against corrosion. Both the initial and final rates of water absorption of BA GPC were about two times less than those of conventional concrete. The BA GPC significantly enhanced performance over equivalent grade conventional concrete (CC).
Sound diffusers, in particular those based on changes in the phase of the reflected wave (Schroeder diffusers), have recently gained greatly in popularity in acoustics as an effective means to eliminate defects and improve the acoustic performance of interiors. This paper draws attention to a possibility of shaping acoustic parameters of sound diffusers and fundamental errors made in applying diffusers. Also, an often neglected issue of sound absorption by diffusers has been tackled. The presented results of laboratory measurements indicate a great significance of the diffusers' rigidity and geometry on their absorption coefficient at low frequencies. The effect of arrangement of elements on the diffusion coefficient was analysed for two types of elements based on the prime number N = 7.
A concept of a highly sensitive and fast-response airborne optoelectronic hygrometer, based on the absorption spectroscopy with laser light tuned to an intense ro-vibronic absorption line of H2O in the 1391– 1393 nm range is presented. The target application of this study is airborne atmospheric measurements, in particular at the top of troposphere and in stratosphere. The cavity ring-down spectroscopy was used to achieve high sensitivity. In order to avoid interference of the results by water desorbed from the instrument walls, the open-path solution was applied. Tests of the instrument, performed in a climatic chamber, have shown some advantages of this concept over typical hygrometers designed for similar applications.
The objective of this work is to present an energy analysis of different absorption refrigerating systems operating with diverse refrigerants. Also is applied the method of experimental design to optimize configurations proposed by the absorption pairs used and the operating conditions. Both acceptable coefficient of performance and low operating generator temperature are scrutinised. Therefore, a computer program is developed. An investigation of the thermodynamic properties is presented. Results show the coefficient of performance evolution versus respectively the evaporator temperature, temperature of condensation and generator temperature. A particular interest is devoted to the intermediate pressure effect on the performance of different systems. In order to better converge in the selection of the configuration and the refrigerant, which can ensure a high coefficient of performance associated to relatively low operating generator temperature the plan of experiments has been developed, taking in account all parameters influencing the system performance and the function of operating temperature. Results show that the refrigerating machine containing a compressor between the evaporator and the absorber has a coefficient of performance quite acceptable and that it can work at low generator temperature for about 60 ◦C and using the NH3/LiNO3 as refrigerant.
The results of experimental investigations on the removal of NOx from gases applying ozone as the oxidizing agent and the absorption of higher nitrogen oxides in the sodium hydroxide solutions are presented. The experiment was conducted using a pilot plant installation with the air flow rate 200 m3/h, being a prototype of a boiler flue gas duct and a FGD scrubber. It was shown that in the range of [NOref] = 50 ÷ 250 ppm the mechanism of NO ozonation depends on the molar ratio X = O3/NOref: for X ≤ 1.0 oxidation of NO to NO2 predominates and NO2 is poorly absorbed, for X >> 1.0 NO2 undergoes further oxidation to N2O5, which is efficiently absorbed in the scrubber. The stoichiometric molar ratio of complete conversion of NO into N2O5 is X = 1.5, in these studies to reach the effectiveness η ≥ 90% the molar ratio X was much higher (2.75).
Fabric covering is often used by designers, as it can easily mask acoustic structures that do not match an interior. However, in the case of sound diffusers based on change in the phase of the reflected wave, the use of fabric covering is not without its effect on acoustics. It reduces the effectiveness of these structures and raises acoustic absorption. In the paper, the authors analyzed the acoustical properties of a selected fabric used to cover sound diffusers. Sound absorption and scattering coefficients for a system composed of sound diffusers and a fabric situated at different distances d were measured. The results were compared to the sound absorption predicted on the basis of Kuttruff’s and Mechel’s theoretical models. Analysis of the results indicates that the fabric has a significant influence on the system’s acoustic parameters. It is also observed, that fabric applied directly on a phase grating diffuser, produces higher absorption than when it is at some distance from it.
The paper presents results of experimental studies on removal of NOx from flue gas via NO ozonation and wet scrubbing of products of NO oxidation in NaOH solutions. The experiment was conducted in a pilot plant installation supplied with flue gas from a coal-fired boiler at the flow rate 200 m3/h. The initial mole fraction of NOx,ref in flue gas was approx. 220 ppm, the molar ratio X = O3/NOref varied between 0 and 2.5. Ozone (O3 content 1÷5% in oxygen) was injected into the flue gas channel before the wet scrubber. The effect of the mole ratio X, the NaOH concentration in the absorbent, the liquid-to-gas ratio (L/G) and the initial NOx concentration on the efficiency of NOx removal was examined. Two domains of the molar ratio X were distinguished in which denitrification was governed by different mechanisms: for X ≤ 1.0 oxidation of NO to NO2 predominates with slow absorption of NO2, for X >> 1.0 NO2 undergoes further oxidation to higher oxides being efficiently absorbed in the scrubber. At the stoichiometric conditions (X = 1) the effectiveness of NO oxidation was better than 90%. However, the effectiveness of NOx removal reached only 25%. When ozonation was intensified (X ≥ 2.25) about 95% of NOx was removed from flue gas. The concentration of sodium hydroxide in the aqueous solution and the liquid-to-gas ratio in the absorber had little effect on the effectiveness of NOx removal for X > 2.
Measurements of the absorption rate of carbon dioxide into aqueous solutions of N-methyldiethanoloamine (MDEA) and 2-ethylaminoethanol (EAE) have been carried out. On this basis a mathematical model of the performance of an absorption column operated with aqueous solution of a blend of the above amines at elevated temperatures and pressures have been proposed. The results of simulations obtained by means of this model are described. The work is a part of a wider program, aimed at the development of a new process.
The presented article describes the method for determining one of the trace elements occurring in coalbismuth. The subjects of the analysis were coal type 34, 35 and their fly ashes derived from Jastrzębska Spółka Węglowa. The main reason for the research was the extensive use of bismuth in many industry sectors. Additionally, bismuth is on the list of deficit elements, therefore the possibility of obtaining an alternative for its recycling source of it is needed, is required. The research was carried out using atomic absorption spectrometry with electrothermal atomization in a graphite cuvette. The samples were incinerated at 800°C and microwave mineralization in a high-pressure closed system was performed until the spectrometric analysis was achieved. In order to achieve mineralization, a mixture of HF and HNO3 acids was used to turn the samples into acidic solutions. The preparation of the samples was based on available literature data and own observations. In the experiment, the effects of the additive modifier was modified by changing the temperature in further steps: drying, incineration, cooling, atomization and burning were described. In addition, the palladium modifier was used in order to limit secondary reactions and enable the evaporation of matrix components. The measurement conditions which are presented in this article allow for a linear calibration curve to be established. However, this is not clear and the definitive method for determining the bismuth in coal is carried out through the use of ET-AAS.
Twenty-eight two-, three-, four-, and five-component amine mixtures have been evaluated as possible activators of CO2 absorption into aqueous carbonate/bicarbonate solutions. Measurements were per- formed using a pressure autoclave with a sparger at conditions close to industrial ones. On the basis of these results, a formula for a new, more efficient amine activator named INS13 was developed. The activator was tested both in a pilot plant and on an industrial scale in an ammonia plant producing 300 tons/day of ammonia. Activator INS13 was applied in a number of ammonia plants in Poland and abroad.
In this study, the magnetic properties and wave absorption characteristics of high entropy alloys are investigated. The high entropy alloys with FeNiMnCoCu, FeNiMnZnCo, and FeNiZnCoCu compositions were synthesized by the sol-gel method. After the sol-gel process, the annealing process and hydrogen reduction process was performed. FeNiMnCoCu and FeNiZnCoCu were revealed soft magnetic property. The saturation magnetization was 12 emu/g and 36 emu/g, respectively. And The coercive force was –45 Oe and –34 Oe, respectively. The high entropy alloy with these compositions was revealed wave absorption property at above 10 gigahertz frequency region. And it has shown the trend that wave absorption frequency has decreased with the sample thickness increasing.
Number of trace compounds (called biomarkers), which occur in human breath, provide an information about individual feature of the body, as well as on the state of its health. In this paper we present the results of experiments about detection of certain biomarkers using laser absorption spectroscopy methods of high sensitivity. For NO, OCS, C2H6, NH3, CH4, CO and CO(CH3)2 an analysis of the absorption spectra was performed. The influence of interferents contained in exhaled air was considered. Optimal wavelengths of the detection were found and the solutions of the sensors, as well as the obtained results were presented. For majority of the compounds mentioned above the detection limits applicable for medicine were achieved. The experiments showed that the selected optoelectronic techniques can be applied for screening devices providing early diseases detection.