Search results

Filters

  • Journals
  • Keywords
  • Date

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The article discusses issues related to improving the energy efficiency of heat supply systems. It draws attention to the need to take action not only for large objects and systems, but also for individual buildings and their boiler plants. Heat supply system monitoring allows for the diagnosis of the weakest elements and making decisions leading to the improvement of energy efficiency. In the case of the boiler room where the research was carried out, the results of such monitoring convinced to equip boilers with an additional automatic control system, with an algorithm limiting the number of burner switching cycles and shutdowns. Limiting the number of switching on the burners, as in the case of other combustion and electric devices, has a significant impact on the energy efficiency of the entire system. In addition, it also increases the durability of the devices, and thus reduces costs of servicing and repairs. The simplest control algorithms, often used in controllers installed in the boiler units, do not provide optimization in this respect. The external device used has allowed the number of burners on and off cycles to be limited while maintaining the quality of the heat supply to the heating installation and the heat treatment system.

The material also presents other ways to improve the energy efficiency of the heat supply system in existing multi-family buildings.

Go to article

Authors and Affiliations

Grzegorz Bartnicki
Bogdan Nowak
Download PDF Download RIS Download Bibtex

Abstract

In recent years, we can observe the development of the thermal diagnosis and operating control systems based on measuring techniques and mathematical modelling of processes improvement. Evaluation of the actual operating state is insufficient to make an optimal operating decisions. Thus, information about the influence of the operating parameters' deviations from the reference state on indicators describing energy consumption of the process (for example specific heat consumption or specific energy consumption) is also necessary. The paper presents methods for generation the information about the influence of the steam-water cycle operating parameters on specific heat consumption in a turbine's cycle. A mathematical model of steam-water cycle for a CHP (Cogeneration - also Combined Heat and Power) unit is being worked out. Methods for calculation of operating deviations with the application of correction curves and a mathematical model are described. Exemplary calculation results are presented.
Go to article

Authors and Affiliations

Henryk Rusinowski
Grzegorz Szapajko