Abstract

The presence of an open-circuit fault subjects a three-phase induction motor to severely unbalanced voltages that may damage the stator windings consecutively causing total shutdown of systems. Unplanned downtime is very costly. Therefore, fault diagnosis is essential for making a predictive plan for maintenance and saving the required time and cost. This paper presents a model-based diagnosis technique for diagnosing an open-circuit fault in any phase of a three-phase induction motor. The proposed strategy requires only current signals from the faulty machine to compare them with the healthy currents from an induction motor model. Then the errors of comparison are used as an objective function for a genetic algorithm that estimates the parameters of a healthy model, which they employed to identify and localize the fault. The simulation results illustrate the behaviours of basic parameters (stator and rotor resistances, self-inductances, and mutual inductance) and the number of stator winding turn parameters with respect to the location of an open-circuit fault. The results confirm that the number of stator winding turns are the useful parameters and can be utilized as an identifier for an open-circuit fault. The originality of this work is in extracting fault diagnosis features from the variations of the number of stator winding turns.

Go to article

Authors and Affiliations

Raya A.K. Aswad
Bassim M.H. Jassim
Download PDF Download RIS Download Bibtex

Abstract

Multilevel inverters have been widely used in various occasions due to their advantages such as lowharmonic content of the outputwaveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, and a diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when an open-circuit fault of the device occurred, and the effect on the circuit switching states and the bridge voltages were analyzed. Then comprehensively considered the bridge voltages, and proposed a fault diagnosis method for a T-type three-level inverter based on specific fault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of the inverter device, and has the advantage of being easy to implement.
Go to article

Bibliography

[1] Karthik A., Loganathan U., A reduced component count five-level inverter topology for high reliability electric drives, IEEE Transactions on Power Electronics, vol. 35, no. 1, pp. 725–732 (2020).
[2] Jin H., Luo Y., Yan Y., Pan S., Improved carrier phase shift modulation and voltage equalization control strategy in modular multilevel converter, Archives of electrical engineering, vol. 68, no. 4, pp. 803–815 (2019).
[3] Majumder M.G., Yadav A.K., Gopakumar K., Raj R.K., Loganathan U., Franquelo L.G., A 5-level inverter scheme using single DC link with reduced number of floating capacitors and switches for open-end IM drives, IEEE Transactions on Industrial Electronics, vol. 67, no. 2, pp. 960–968 (2020).
[4] Lewicki A., Morawiec M., Structure and the space vector modulation for a medium-voltage powerelectronic- transformer based on two seven-level cascade H-bridge inverters, IET Electric Power Applications, vol. 13, no. 10, pp. 1514–1523 (2019).
[5] Li X., Xing X., Zhang C., Chen A., Qin C., Zhang G., Simultaneous common-mode resonance circulating current and leakage current suppression for transformerless three-level T-ype PV inverter system, IEEE Transactions on Industrial Electronics, vol. 66, no. 6, pp. 4457–4467 (2019).
[6] Qin S., Lei Y., Ye Z., Chou D., Pilawa-Podgurski R.C.N., A high-power-density power factor correction front end based on seven-level flying capacitor multilevel converter, IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 7, no. 3, pp. 1883–1898 (2019).
[7] Kim H., Kwon Y., Chee S., Sul S., Analysis and compensation of inverter nonlinearity for three-level T-type inverters, IEEE Transactions on Power Electronics, vol. 32, no. 6, pp. 4970–4980 (2017).
[8] Wang B., Li Z., Bai Z., Krein P.T., Ma H., A redundant unit to form T-type three-level inverters tolerant of IGBT open-circuit faults in multiple legs, IEEE Transactions on Power Electronics, vol. 35, no. 1, pp. 924–939 (2020).
[9] Wang B., Li Z., Bai Z., Krein P.T., Ma H., Real-time diagnosis of multiple transistor open-circuit faults in a T-type inverter based on finite-state machine model, CPSS Transactions on Power Electronics and Applications, vol. 5, no. 1, pp. 74–85 (2020).
[10] Choi U., Lee K., Blaabjerg F., Diagnosis and tolerant strategy of an open-switch fault for T-type three-level inverter systems, IEEE Transactions on Industry Applications, vol. 50, no. 1, pp. 495–508 (2014).
[11] He J., Demerdash N.A.O.,Weise N., Katebi R., A fast on-line diagnostic method for open-circuit switch faults in SiC-MOSFET-based T-type multilevel inverters, IEEE Transactions on Industry Applications, vol. 53, no. 3, pp. 2948–2958 (2017).
[12] Wang K., Tang Y., Zhang C., Open-circuit fault diagnosis and tolerance strategy applied to four-wire T-type converter systems, IEEE Transactions on Power Electronics, vol. 34, no. 6, pp. 5764–5778 (2019).
[13] Wang X., Wang Z., Xu Z., He J., Zhao W., Diagnosis and tolerance of common electrical faults in Ttype three-level inverters fed dual three-phase PMSM drives, IEEE Transactions on Power Electronics, vol. 35, no. 2, pp. 1753–1769 (2020).
[14] Schweizer M., Kolar J.W., Design and implementation of a highly efficient three-level T-type converter for low-voltage applications, IEEE Transactions on Power Electronics, vol. 28, no. 2, pp. 899–907 (2013). Vol. 70 (2021) Fault diagnosis of T-type three-level inverter 87
[15] Wang K., Tang Y., Zhang C., Open-circuit fault diagnosis and tolerance strategy applied to four-wire T-type converter systems, IEEE Transactions on Power Electronics, vol. 34, no. 6, pp. 5764–5778 (2019).
[16] Abadi M.B., Mendes A.M.S., Cruz S.M.Â., Method to diagnose open-circuit faults in active power switches and clamp-diodes of three-level neutral-point clamped inverters, IET Electric Power Applications, vol. 10, no. 7, pp. 623–632 (2016).
[17] Zhou D., Yang S., Tang Y., A voltage-based open-circuit fault detection and isolation approach for modular multilevel converters with model-predictive control, IEEE Transactions on Power Electronics, vol. 33, no. 11, pp. 9866–9874 (2018).
[18] Chen D., LiuY., Zhang S., Open-circuit fault diagnosis method for the T-type inverter based on analysis of the switched bridge voltage, IET Power Electronics, vol. 12, no. 2, pp. 295–302 (2019
Go to article

Authors and Affiliations

Danjiang Chen
1
ORCID: ORCID
Yutian Liu
1
Shaozhong Zhang
1

  1. College of Information and Intelligence Engineering, Zhejiang Wanli University, China
Download PDF Download RIS Download Bibtex

Abstract

Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
Go to article

Authors and Affiliations

Danjiang Chen
1
ORCID: ORCID
Liyuan Zheng
1
ORCID: ORCID

  1. College of Information and Intelligence Engineering, Zhejiang Wanli University, No. 8, South Qian Hu Road, Ningbo, Zhejiang, China 315100