Wyniki wyszukiwania

Wyników: 3
Wyników na stronie: 25 50 75
Sortuj wg:

Abstrakt

This paper briefly describes direct power control methods for two- and threelevel AC/DC converters and their modified DPC 3H 2-? and the DPC 5H2-? algorithms. It also presents two new control methods DPC-3Am (direct power control 3 areas with modification) and the DPC-3L-3Am (direct power control 3 levels 3 areas with modification). The research results were used to compare the described methods. The comparison was based on an average value of switching frequency and current distortion coefficient. Experimental investigations into the methods have shown that the use of the modified DPC methods reduces the number of switchings by more than 70% compared with the standard DPC method.

Przejdź do artykułu

Autorzy i Afiliacje

Krzysztof Kulikowski

Abstrakt

In this paper a system of a grid side and a generator side converters, both working with a common capacitor, is presented. The 6-phase asymmetric inset-type SMPMSM generator is used. A large pole pair number of this generator enables a gearless wind turbine operation. The fundamental and 3rd harmonic cooperation is used to increase the generator performance. This is accomplished by means of the 3rd harmonic current injection. For that reason the generator side converter must have a neutral connection.

Przejdź do artykułu

Autorzy i Afiliacje

Marek Gołębiowski
Lesław Gołębiowski
Damian Mazur
Matthias Humer

Abstrakt

The neutral point clamped (NPC) three-level grid-tied converter is the key equipment connecting renewable energy and power grids. The current sensor fault caused by harsh environment may lead to the split of renewable energy. The existing sensor fault-tolerant methods will reduce the modulation ratio index of the converter system. To ensure continuous operation of the converter system and improve the modulation index, a model predictive control method based on reconstructed current is proposed in this paper. According to the relationship between fault phase current and a voltage vector, the original voltage vector is combined and classified. To maintain the stable operation of the converter and improve the utilization rate of DC voltage, two kinds of fault phase current are reconstructed with DC current, normal phase current and predicted current, respectively. Based on reconstructed three-phase current, a current predictive control model is designed, and a model predictive control method is proposed. The proposed method selects the optimal voltage vector with the cost function and reduces time delay with the current reconstruction sector. The simulation and experimental results showthat the proposed strategy can keep the NPC converter running stably with one AC sensor, and the modulation index is increased from 57.7% to 100%.
Przejdź do artykułu

Autorzy i Afiliacje

Yanyan Li
1
ORCID: ORCID
Han Xiao
1
Nan Jin
1
ORCID: ORCID
Guanglu Yang
1 2

  1. College of Electrical and Information Engineering, Zhengzhou University of Light Industry, China
  2. Nanyang Cigarette Factory, China Tobacco Henan Industrial Co., Ltd., China