Details

Title

Improving sensitivity of residual current transformers to high frequency earth fault currents

Journal title

Archives of Electrical Engineering

Yearbook

2017

Volume

vol. 66

Issue

No 3 September

Authors

Divisions of PAS

Nauki Techniczne

Publisher

Polish Academy of Sciences

Date

2017

Identifier

DOI: 10.1515/aee-2017-0036 ; ISSN: 1427-4221 ; eISSN: 2300-2506

Source

Archives of Electrical Engineering; 2017; vol. 66; No 3 September

References

Colin (2008), Mas Wound magnetic core consequences on false residual currents : for and in and vol iss pp, COMPEL The International Journal Computation Mathematics Electrical Electronic Engineering, 13, 27, doi.org/10.1108/03321640810836807 ; Czapp (2009), Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices ir vol no pp, Elektronika Elektrotechnika, 17, 85. ; Ladjimi (2012), Thermal effects on magnetic hysteresis modelling of vol no pp, Archives Electrical Engineering, 14, 61, doi.org/10.2478/v10171-012-0007-1 ; Naghizadeh (2014), Calculation of inrush current using adopted parameters of the hysteresis loop : for and in and vol iss pp, COMPEL The International Journal Computation Mathematics Electrical Electronic Engineering COMPEL, 15, 1794, doi.org/10.1108/-08-2012-0133 ; Nová (2013), Dynamic hysteresis loops modeling by means of extended hyperbolic model on vol no pp, IEEE Transactions Magnetics, 16, 49, doi.org/10.1109/TMAG.2012.2218584 ; Luo (2011), Tripping characteristics of residual current devices under nonsinusoidal currents on Industry Applications vol no pp, IEEE Transactions, 47. ; Czapp (2010), Comparison of residual current devices tripping characteristics for selected residual current waveforms ir vol no pp, Elektronika Elektrotechnika, 100, 7. ; Czapp (2013), of residual current devices to the impulse leakage current in circuits with variable speed drives ir vol no pp, Immunity Elektronika Elektrotechnika, 19, 15, doi.org/10.5755/j01.eee.19.8.2883 ; Czapp (2008), The effect of earth fault current harmonics on tripping of residual current devices Proceedings of the International School on Nonsinusoidal Currents and Compensation IX Conference - Seminar, null, doi.org/10.1109/ISNCC.2008.4627489 ; Freschi (2012), High - frequency behavior of residual current devices on vol no pp, IEEE Transactions Power Delivery, 27, 1629, doi.org/10.1109/TPWRD.2012.2191423 ; Lee (1995), The effects of harmonics on the operational characteristics of residual current circuit breakers International Conference on Energy Management and Power Delivery Proceedings of, null, 95, doi.org/10.1109/EMPD.1995.500786 ; Chwastek (2011), The effect of anisotropy in the modified model of static hysteresis of vol no pp, Archives Electrical Engineering, 12, 60, doi.org/10.2478/v10171-011-0005-8 ; Donahue (2014), Study of the effects of smart meter RF transmissions on GFCI outlets on vol no pp, IEEE Transactions Electromagnetic Compatibility, 1361, doi.org/10.1109/TEMC.2014.2354016 ; Roldan (2014), Nuisance tripping of residual current circuit breakers practical case, Electric Power Systems Research, 9, 106, doi.org/10.1016/j.epsr.2013.07.020

Open Access Policy

Archives of Electrical Engineering is an open access journal with all content available with no charge in full text version.


The journal content is available under the licencse CC BY-NC-ND 4.0. https://creativecommons.org/licenses/by-nc-nd/4.0/
×