Abstract

In the finite control set model predictive control (FCS-MPC) strategy of the grid-tied inverter, the current ripple (CR) affects the selection of optimal voltage vectors, which leads to the increase of output current ripples. In order to solve this problem, this paper proposes a CR reduction method based on reference current compensation (RCC) for the FCS-MPC strategy of grid-tied inverters. Firstly, the influence of the CR on optimal voltage vector selection is analyzed. The conventional CR prediction method is improved, which uses inverter output voltage and grid voltage to calculate current ripples based on the space state equation. It makes up for the shortcomings that the conventional CR prediction method cannot predict in some switching states. The improved CR method is more suitable for the FCS-MPC strategy. In addition, the differences between the two cost functions are compared through visual analysis. It is found that the sensitivity of the square cost function to small errors is better than that of the absolute value function. Finally, the predicted CR is used to compensate the reference current. The compensated reference current is substituted into the square cost function to reduce the CR. The experimental results show that the proposed method reduces the CR by 47.3%. The total harmonic distortion (THD) of output current is reduced from 3.86% to 2.96%.
Go to article

Authors and Affiliations

Nan Jin
1
ORCID: ORCID
Wuchuang Fan
1
Jie Fang
1
Jie Wu
1
Yongpeng Shen
1

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China
Download PDF Download RIS Download Bibtex

Abstract

The disadvantages of the conventional model predictive current control method for the grid-connected converter (GCC) with an inductance-capacitance-inductance (LCL) filter are a large amount of calculation and poor parameter robustness. Once parameters of the model are mismatched, the control accuracy of model predictive control (MPC) will be reduced, which will seriously affect the power quality of the GCC. The article intuitively analyzes the sensitivity of parameter mismatch on the current predictive control of the conventional LCL-filtered GCC. In order to solve these issues, a model-free predictive current control (MFPCC) method for the LCL-filtered GCC is proposed in this paper. The contribution of this work is that a novel current predictive robust controller for the LCL-filtered GCC is designed based on the principle of the ultra-local model of a single input single output system. The proposed control method does not require using any model parameters in the controller, which can effectively suppress the disturbances of the uncertain parameter variations. Compared with conventional MPC, the proposed MFPCC has smaller current total harmonic distortion (THD). When the filter parameters are mismatched, the control error of the proposed method is smaller. Finally, a comparative experimental study is carried out on the platform of Typhoon and PE-Expert4 to verify the superiority and effectiveness of the proposed MFPCC method for the LCL-filtered GCC.
Go to article

Authors and Affiliations

Leilei Guo
1
Mingzhe Zheng
1
ORCID: ORCID
Changzhou Yu
2
Haizhen Xu
2
Yanyan Li
1
ORCID: ORCID

  1. Zhengzhou University of Light Industry, College of Electrical and Information Engineering, China
  2. Hefei University, School of Advanced Manufacturing Engineering, China
Download PDF Download RIS Download Bibtex

Abstract

In this paper, an analysis of the properties of a switched reluctance motor (SRM) 8/6 in an extended constant power range is presented. The typical constant power range to constant torque range ratio is between 2 and 3. In the case of machines designed as an electric vehicle drive, it is important to maximize this ratio. In the case of an SRM, it is possible to achieve this by applying an appropriate control strategy. An analysis of the SRM operation utilizing a modified control algorithm allows control of the maximum value of the motor phase current. As a consequence, using the so-called nonzero initial conditions for the current and flux allows the output power to be maintained in a wide speed range. For the improvement of drive system efficiency, the work of the phase current regulator should be limited to a minimum. The most advantageous work conditions we obtain with single-time current regulator work. Laboratory verification has been performed for selected states of motor work.
Go to article

Authors and Affiliations

Mariusz Korkosz
1
ORCID: ORCID
Grzegorz Podskarbi
1
Krystyna Krzywdzińska-Kornak
1

  1. Faculty of Electrical and Computer Engineering, Rzeszow University of Technology, Al. Powstanców Warszawy 12, 35-959 Rzeszów, Poland
Download PDF Download RIS Download Bibtex

Abstract

A three-level multi-input DC/DC converter is proposed to solve the problems of complex interface circuit structure and high economic cost for multi-source access to the joint power supply distribution system. In this structure, multiple dc sources are integrated into a three-level DC/DC converter. In comparison with the two-stage counterpart, two active switches and boost diodes are eliminated, while two blocking diodes are added to block the reverse current from the dc-link capacitors. In addition, when the input inductors work in the discontinuous conduction mode, power sharing among different input sources can be achieved by properly selecting the inductance value. The working principle of the converter is analyzed by introducing nine working modes in detail and deriving the steady-state relationship expressions. The parameter range of the element is determined and the design process of a group of dynamic parameter values is shown. Finally, the power electronics real-time simulation platform is built based on StarSim HIL and the corresponding experimental waveforms are given to verify the topology and analysis.
Go to article

Authors and Affiliations

Jingjing Tian
1
Jiaoping Qu
1
ORCID: ORCID
Feng Zhao
1
Xiaoqiang Chen
1 2
Ying Wang
1 2
ORCID: ORCID
Yang Gan
1

  1. School of Automation & Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
  2. Key Laboratory of Opto-technology and Intelligent Control, Lanzhou Jiaotong University, Ministry of Education, Lanzhou, China
Download PDF Download RIS Download Bibtex

Abstract

In recent years, due to the increasing number of renewable energy sources, which are characterised by the stochastic nature of the generated power, interest in energy storage has increased. Commercial installations use simple deterministic methods with low economic efficiency. Hence, there is a need for intelligent algorithms that combine technical and economic aspects. Methods based on computational intelligence (CI) could be a solution. The paper presents an algorithm for optimising power flow in microgrids by using computational intelligence methods. This approach ensures technical and economic efficiency by combining multiple aspects in a single objective function with minimal numerical complexity. It is scalable to any industrial or residential microgrid system. The method uses load and generation forecasts at any time horizon and resolution and the actual specifications of the energy storage systems, ensuring that technological constraints are maintained. The paper presents selected calculation results for a typical residential microgrid supplied with a photovoltaic system. The results of the proposed algorithm are compared with the outcomes provided by a deterministic management system. The computational intelligence method allows the objective function to be adjusted to find the optimal balance of economic and technical effects. Initially, the authors tested the invented algorithm for technical effects, minimising the power exchanged with the distribution system. The application of the algorithm resulted in financial losses, €12.78 for the deterministic algorithm and €8.68 for the algorithm using computational intelligence. Thus, in the next step, a control favouring economic goals was checked using the CI algorithm. The case where charging the storage system from the grid was disabled resulted in a financial benefit of €10.02, whereas when the storage system was allowed to charge from the grid, €437.69. Despite the financial benefits, the application of the algorithm resulted in up to 1560 discharge cycles. Thus, a new unconventional case was considered in which technical and economic objectives were combined, leading to an optimum benefit of €255.17 with 560 discharge cycles per year. Further research of the algorithm will focus on the development of a fitness function coupled to the power system model.
Go to article

Authors and Affiliations

Dominika Kaczorowska
1
ORCID: ORCID
Jacek Rezmer
1
ORCID: ORCID
Przemysław Janik
1
ORCID: ORCID
Tomasz Sikorski
1
ORCID: ORCID

  1. Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland
Download PDF Download RIS Download Bibtex

Abstract

Modern drives with Permanent Magnet Synchronous Motors (PMSMs) require both efficient control structure to ensure excellent dynamics and effective diagnostic algorithms to detect the motor faults that can occur. This paper shows the combination of both mentioned aspects – the direct-axis based signals of the Field Oriented Control (FOC) structure are proposed as diagnostic signals to allow diagnosing the interturn short-circuit failure that can appear inside stator windings. The amplitudes of second order harmonics are selected as the fault indicators. Different modelling methods are analysed and compared in detail in this paper: an analytical mathematical model, a Finite Element Method (FEM)- based model and next verified using a laboratory setup. The results obtained using all the mentioned models proved that the proposed fault indices are increasing significantly with the number of shorted turns and are independent on the load torque level.
Go to article

Authors and Affiliations

Mateusz Krzysztofiak
1
ORCID: ORCID
Tomasz Zawilak
1
ORCID: ORCID
Grzegorz Tarchała
1
ORCID: ORCID

  1. Wrocław University of Science and Technology, Department of Electrical Machines, Drives and Measurements, Wybrzeze Wyspianskiego 27, 50-370 Wrocław, Poland
Download PDF Download RIS Download Bibtex

Abstract

The development of research on the maximum power point tracking (MPPT) controller has increased significantly in this decade. The MPPT technique, however, is still demanding because of the ease and simplicity of implementing tracking technique on the maximum power point (MPP). In this paper, MPPT techniques and their modifications from various literature are classified and examined in detail. The discussions are focused on the main objective of obtaining the best possible MPPT technique with the best results at a low cost. The assessment for the selection of MPPT techniques is based on assessments from the previous literature. The discussion of the MPPT technique assessment is divided into two parts. In Part I, the MPPT technique based on constant parameters, and trial-and-error will be discussed in detail, along with its algorithm development in recent times.
Go to article

Authors and Affiliations

Tole Sutikno
1
ORCID: ORCID
Arsyad Cahya Subrata
1
ORCID: ORCID
Giovanni Pau
2
ORCID: ORCID
Awang Jusoh
3
ORCID: ORCID
Kashif Ishaque
4
ORCID: ORCID

  1. Department of Electrical Engineering, Universitas Ahmad Dahlan, Yogyakarta, Indonesia
  2. Faculty of Engineering and Architecture, Kore University of Enna, Italy
  3. School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
  4. Capital University of Science and Technology, Islamabad, Pakistan
Download PDF Download RIS Download Bibtex

Abstract

The problem of an inconsistent description of an “interface” between the A/D converter and the digital signal processor that implements, for example, a digital filtering (described by a difference equation) – when a sequence of some hypothetical weighted Dirac deltas occurs at its input, instead of a sequence of numbers – is addressed in this paper. Digital signal processors work on numbers, and there is no “interface” element that converts Dirac deltas into numbers. The output of the A/D converter is directly connected to the input of the signal processor. Hence, a clear conclusion must follow that sampling devices do not generate Dirac deltas. Not the other way around. Furthermore, this fact has far-reaching implications in the spectral analysis of discrete signals, as discussed in other works referred to in this paper.
Go to article

Authors and Affiliations

Andrzej Borys
1
ORCID: ORCID

  1. Department of Marine Telecommunications, Electrical Engineering Faculty, Gdynia Maritime University, ul. Morska 81-87, 81-225 Gdynia, Poland
Download PDF Download RIS Download Bibtex

Abstract

This paper presents new directions in the modeling of electric arc furnaces. This work is devoted to an overview of new approaches based on random differential equations, artificial neural networks, chaos theory, and fractional calculus. The foundation of proposed solutions consists of an instantaneous power balance equation related to the electric arc phenomenon. The emphasis is mostly placed on the conclusions that come from a novel interpretation of the equation coefficients.
Go to article

Authors and Affiliations

Dariusz Grabowski
1
ORCID: ORCID
Maciej Klimas
1
ORCID: ORCID

  1. Faculty of Electrical Engineering, Silesian University of Technology, Akademicka 10 str., 44-100 Gliwice, Poland
Download PDF Download RIS Download Bibtex

Abstract

This paper proposes two nonlinear exact and simple state space models of a Zsource converter (ZSC) connected to an ac grid. A generic model of a ZSC accompanied with proper controllers are proposed and a dynamic model of the whole system is derived; as a result, based on a simple one, an equivalent block diagram of the current-controlled ZSC system is proposed. The ac small signal stability method is applied and the impact of controller parameters on network’s stability is discussed. Besides, overall system dynamic performance has been assessed in the event of perturbations. Time-domain simulations have been implemented in PSCAD/EMTDC to validate the accuracy of the models and effectiveness of the proposed controllers. The results of the exact model are compared with the response of the equations which are applied in MATLAB.
Go to article

Authors and Affiliations

Masoud Jokar Kouhanjani
1
ORCID: ORCID
Sina Soltani
2
ORCID: ORCID
Mohammad Mardaneh
3
ORCID: ORCID

  1. Department of Technical Study, Shiraz Electric Distribution Company, Shiraz, Iran
  2. Department of Control and Management, Neyriz Ghadir Steel Complex (NGHSCO), Fars, Iran
  3. Department of Power and Control Engineering, Shiraz University of Technology, Shiraz, Iran
Download PDF Download RIS Download Bibtex

Abstract

Fractional-slot concentrated-winding permanent magnet synchronous machines (FSCW-PMSMs) have a good prospect of application in the drive system of electric and hybrid electric vehicles. However, the armature magnetomotive force (MMF) of FSCWPMSM contains a large number of space harmonics, which induce large magnet eddycurrent loss (ECL). To solve this problem, a dual three-phase 10-pole and 24-slot winding layout is proposed.MMFharmonic analysis shows that the 1st, 7th and 17th space-harmonic winding factors of the proposed winding can be reduced by 100%, 87% and 87% respectively, compared with a dual three-phase 10-pole and 12-slot winding. Electromagnetic performances of the proposed machine under rated sinusoidal current supply and space vector pulse-width-modulated (SVPWM) voltage supply are investigated based on 2D finite-element analysis. It is shown that the proposed machine can meet the requirement of torque and efficiency in the full speed range. Especially, magnet ECL can be reduced greatly due to the reduction of the 7th and 17th space harmonics.
Go to article

Authors and Affiliations

Zhenfei Chen
1
Ning Xing
2
Hongzhong Ma
1
Zhixin Li
3
Jiayu Li
1
Chenyang Fan
1

  1. College of Energy and Electrical Engineering, Hohai University Jiangsu, China
  2. School of Electrical and Information Engineering, Tianjin University Tianjin, China
  3. Electric Power Science Research Institute, Jiangsu Electric Power Company, Jiangsu, China
Download PDF Download RIS Download Bibtex

Abstract

This paper presents a comparative study between the conventional PI (Proportional Integral) and backstepping controllers applied to the DFIG (Doubly Fed Induction Generator) used in WECS (Wind Energy Conversion System). These two different control strategies proposed in this work are developed to control the active and reactive power of the DFIG on the one hand, and to maintain the DC-link voltage constant for the inverting function on the other hand. This is ensured by generating control signals for two power electronic converters, RSC (Rotor Side Converter) and GSC (Grid Side Converter). In order to optimise the power production in the WT (Wind Turbine), an MPPT (Maximum Power Point Tracking) algorithm is applied along with each control technique. To simulate the effectiveness of the proposed controllers, MATLAB/Simulink Software is used, and the obtained results are analysed and discussed to compare PI and backstepping controllers in terms of robustness against wind speed variations and tracking performance in dynamic and steady states.
Go to article

Authors and Affiliations

Youssef Moumani
1
ORCID: ORCID
Abdeslam Jabal Laafou
1
ORCID: ORCID
Abdessalam Ait Madi
1
ORCID: ORCID

  1. Advanced Systems Engineering Laboratory, National School of Applied Sciences, Ibn Tofail University, Kenitra, Morocco
Download PDF Download RIS Download Bibtex

Abstract

In vivo biomedical devices are one of the most studied applications for vibrational energy harvesting. In this paper, we investigated a novel high-displacement device for harvesting heartbeats to power leadless implantable pacemakers. Due to the location peculiarities, certain constraints must be respected for the design of such devices. Indeed, the total dimension of the system must not exceed 5.9 mm to be usable within the leadless pacemakers and it must be able to generate accelerations lower than 0.25 m/s2 at frequencies of less than 50 Hz. The proposed design is an electrostatic system based on a square electret of dimension 4.5 mm. It is based on the Quasi-Concertina structure, which has a very low resonant frequency of 26.02 Hz and a low stiffness of 0.492 N/m, allowing it to be very useful in such an application. Using a Teflon electret charged at 1000 V, the device was able to generate an average power of 10.06 μW at a vibration rate of 0.25 m/s2 at the resonant frequency.
Go to article

Authors and Affiliations

Bilel Maamer
1
ORCID: ORCID
Nesrine Jaziri
1 2
ORCID: ORCID
Mohamed Hadj Said
3
ORCID: ORCID
Fares Tounsi
1
ORCID: ORCID

  1. Systems Integration and Emerging Energies (SI2E), École nationale d’ingénieurs de Sfax, Université de Sfax 3038 Sfax, Tunisia
  2. Electronics Technology Group, Institute of Micro and Nanotechnologies MacroNanoTechnische Universität Ilmenau, Gustav-Kirchhoff-Straße 1 Ilmenau 98693, Germany
  3. Center for Research in Microelectronics and Nanotechnology (CRMN) Sousse 4050, Tunisia
Download PDF Download RIS Download Bibtex

Abstract

This paper reports a new strand wire winding method in a solenoidal coil with limited geometry that enables good impedance matching. In the proposed method strand wires are wound layer-by-layer on top of each other allowing one to set equivalent inductance and resistance of the coil to desired values while obtaining dense magnetic flux and high current carrying capacity. As a proof-of-concept demonstration, simple model setups were constructed with solenoidal coils composed of copper wire strands wound according to the proposed method, and a plastic pipe. The measurements were repeated with a metal shell placed inside the coil to model a complete heating system. System inductance and resistance were measured at two different frequencies. The results show that with the new winding method it is possible to increase a coil’s turn number and the number of strand layers composed by the coil. Also, adding and removing strand layers in the proposed coil architectures enable inductance and resistance values to decrease and increase, respectively, in a controlled way. To understand changes of system parameters, simulations were also performed. The calculated inductance and resistance values in the simulations agree well with the measurement results and magnetic flux distribution created in the system demonstrates the changes.
Go to article

Authors and Affiliations

Veli Tayfun Kilic
1

  1. Department of Electrical and Electronics Engineering, Abdullah Gul University, Kayseri, Turkiye
Download PDF Download RIS Download Bibtex

Abstract

One of the most important aims of the sizing and allocation of distributed generators (DGs) in power systems is to achieve the highest feasible efficiency and performance by using the least number of DGs. Considering the use of two DGs in comparison to a single DG significantly increases the degree of freedom in designing the power system. In this paper, the optimal placement and sizing of two DGs in the standard IEEE 33-bus network have been investigated with three objective functions which are the reduction of network losses, the improvement of voltage profiles, and cost reduction. In this way, by using the backward-forward load distribution, the load distribution is performed on the 33-bus network with the power summation method to obtain the total system losses and the average bus voltage. Then, using the iterative search algorithm and considering problem constraints, placement and sizing are done for two DGs to obtain all the possible answers and next, among these answers three answers are extracted as the best answers through three methods of fuzzy logic, the weighted sum, and the shortest distance from the origin. Also, using the multi-objective non-dominated sorting genetic algorithm II (NSGA-II) and setting the algorithm parameters, thirty-six Pareto fronts are obtained and from each Pareto front, with the help of three methods of fuzzy logic, weighted sum, and the shortest distance from the origin, three answers are extracted as the best answers. Finally, the answer which shows the least difference among the responses of the iterative search algorithm is selected as the best answer. The simulation results verify the performance and efficiency of the proposed method.
Go to article

Authors and Affiliations

Hossein Ali Khoshayand
1
ORCID: ORCID
Naruemon Wattanapongsakorn
2
ORCID: ORCID
Mehdi Mahdavian
1
ORCID: ORCID
Ehsan Ganji
1
ORCID: ORCID

  1. Department of Electrical Engineering, Naein Branch, Islamic Azad University, Iran
  2. Department of Computer Engineering, King Mongkut’s University of Technology, Thonburi, 126 Prachautid Road, Bangmod, Bangkok 10140, Thailand
Download PDF Download RIS Download Bibtex

Abstract

The paper proposes a newrobust fuzzy gain adaptation of the sliding mode (SMC) power control strategy for the wind energy conversion system (WECS), based on a doubly fed induction generator (DFIG), to maximize the power extracted from the wind turbine (WT). The sliding mode controller can deal with any wind speed, ingrained nonlinearities in the system, external disturbances and model uncertainties, yet the chattering phenomenon that characterizes classical SMC can be destructive. This problem is suitably lessened by adopting adaptive fuzzy-SMC. For this proposed approach, the adaptive switching gains are adjusted by a supervisory fuzzy logic system, so the chattering impact is avoided. Moreover, the vector control of the DFIG as well as the presented one have been used to achieve the control of reactive and active power of the WECS to make the wind turbine adaptable to diverse constraints. Several numerical simulations are performed to assess the performance of the proposed control scheme. The results show robustness against parameter variations, excellent response characteristics with a reduced chattering phenomenon as compared with classical SMC.
Go to article

Authors and Affiliations

Mohamed Horch
1
ORCID: ORCID
Abdelkarim Chemidi
2
ORCID: ORCID
Lotfi Baghli
3
ORCID: ORCID
Sara Kadi
4
ORCID: ORCID

  1. Laboratoire d’Automatique de Tlemcen (LAT), National School of Electrical and Energetic Engineering of Oran, Oran 31000, Algeria
  2. Manufacturing Engineering Laboratory of Tlemcen, Hight School of Applied Sciences, Tlemcen 13000, Algeria
  3. Laboratoire d’Automatique de Tlemcen (LAT) Université de Lorraine GREEN, EA 4366F-54500, Vandoeuvre-lès-Nancy, France
  4. Laboratory of Power Equipment Characterization and Diagnosis, University of Science and Technology Houari Boumediene, Algiers 16000, Algeria

Instructions for authors

ARCHIVES OF ELECTRICAL ENGINEERING (AEE) (previously Archiwum Elektrotechniki), quarterly journal of the Polish Academy of Sciences is OpenAccess, publishing original scientific articles and short communiques from all branches of Electrical Power Engineering exclusively in English. The main fields of interest are related to the theory & engineering of the components of an electrical power system: switching devices, arresters, reactors, conductors, etc. together with basic questions of their insulation, ampacity, switching capability etc.; electrical machines and transformers; modelling & calculation of circuits; electrical & magnetic fields problems; electromagnetic compatibility; control problems; power electronics; electrical power engineering; nondestructive testing & nondestructive evaluation.

Manuscript submission:

All manuscripts should be submitted electronically on Editorial System.

Submission of paper to the Archives of Electrical Engineering is understood to imply that the article is original, unpublished and is not being considered for publication elsewhere. All articles will be reviewed. Since 2013, Authors wishing to use the facility of colour printing should consult the editors.

Template:

Microsoft Word is recommended as a standard word processor to prepare the paper to the AEE journal. If you use the LaTex format, please transfer your document to Microsoft Word and then use Template AEE.

While editing your paper, make sure that all the mathematical characters (symbols, identifiers, variables, vectors, axis marks, etc.) have the required shape, thickness, and slant kept throughout the whole article. The same appearance of a given mathematic character must be retained regardless of its place (text, equations, tables or figures).

The articles that don’t conform to the above will not be processed and published.

The reviewing process:

Each paper submitted for publication in Archives of Electrical Engineering is subjected to the following review procedure:

a) the paper is reviewed by the editor in chief or guest editor for general suitability for publication in AEE

b) if it is judged suitable two reviewers are selected and a double blind peer review process takes place

c) based on the recommendations of the reviewers, the editor then decides whether the paper should be accepted in its present form, revised or rejected

d) the author(s) is(are) informed by e-mail on the results of the reviewing procedure.

The papers are published on average within 3 months after acceptance.

Requirements for preparation of manuscripts:

The manuscript submitted for publication should have no less than 12 pages and no more than 16 pages. In the case of the manuscript longer than 16 pages, please contact the AEE Editorial Board before submitting your paper. The manuscripts, written in UK English, should be typed using Template AEE according to the following instructions and should include: a title page with the title of a manuscript, a short title; abstract; key words, text; list of references. A DOI number as well as received and revised data will be completed by Editor. When you open Template.doc, select "Print Layout" from the "View" menu in the menu bar (View > Print Layout). Then type over sections of Template.doc or cut and paste from another document and then use markup styles (Home > Styles). For example, the style at this point in the document is "main text").

All papers submitted for publication are assessed on the basis of the mutual anonymity rule as to the names of reviewers and authors. Authors' names and affiliations should not appear in the attached text/tables/figures.

If English is not your first language, ask an English-speaking colleague to proofread your manuscript. The manuscripts that fail to meet basic standards of literacy are likely to be immediately declined or after the language assessment, sent to the authors for linguistic improvement.

The manuscripts are published on average within 3 months after their acceptance.

Do not change the font sizes or line spacing to squeeze more text into a limited number of pages. Leave some open space around your figures.

The AEE journal publishes an ORCID for all authors. You will need a registered ORCID in order to submit your paper for peer review. ORCID registration is free and only takes a minute. Please note that ORCIDs will be added in the course of the author's proofreads.

Text:

The pages must be numbered consecutively. Articles should be divided into numbered sections, and if necessary subsections, preferably: Introduction, Material, Methods, Results, Conclusion and References. Any special characters (e.g. Greek, script, etc.) should be named in the margin where the character first occurs in the text. Names of species are to be accentuated with wavy underlining (italics). Equations should be numbered serially (1), (2), ... on the right side of the page. Footnotes should be avoided, if required, they should be used only for brief notes which do not fit well into the text. Figures and tables have to be included into the text. If table is typed on a separate page its position in the text should be marked. Abbreviations should be explained when they first appear in the text.

Math:

Please use the MathML editor as well as MathType editor to build an equation in your manuscript.

Equations:

Equations should be typed within the text, centred, and should be numbered consecutively throughout the text. Their numbers should be typed in parentheses, flush right. Equations should be referred to in text, e.g. (1), except at the beginning of a sentence: "Equation (1) is ...". All symbols appearing in equations have to be defined in the text, before or just after the equation.

If the symbols are written in Times New Roman use italic fonts. Symbols of vectors and matrices should be written in bold fonts. Do not italicize Greek fonts and mathematical symbols like e.g.: the derivative symbol d, max, min, etc. The indices of symbols that are indices themselves should be written in a clear manner.

Note that the equation is centered using a center tab stop. Please keep the same font in the formulas and text.

Unit Symbols, Abbreviations:

Define abbreviations and acronyms the first time they are used in the text, even after they have been defined in the abstract. Abbreviations such as IEEE, SI, MKS, CGS, sc, dc, and rms do not have to be defined. Do not use abbreviations in the title or heads unless they are unavoidable.

Si units are recommended for use in formulas, drawings and tables., for example the SI unit for magnetic field strength H is A/m. Apply the center dot to separate compound units.

Do not mix complete spellings and abbreviations of units: "Wb/m2" or "webers per square meter," not "webers/m2." Spell units when they appear in text: "...a few henries…", not "...a few H…".

Use a zero before decimal points: "0.25," not ".25." Use "cm3," not "cc."

Unit Symbols, SI Prefixes as well as Abbreviations should be writing in accordance with the IEEE standard

Tables, figures (illustrations) and captions:

The illustrations (line diagrams and photographs) should be suitable for direct reproduction. The lettering as well the details should have proportional dimensions to maintain their legibility after the usual reduction. All illustrations should be numbered consecutively (Fig. X). Tables are numbered with Arabic numerals.

All figures, figure captions, and tables in the text must be inserted into the correct places.

Figures, photos, tables or other parts of a manuscript that have previously appeared in another publication or are not the property of the authors must be properly acknowledged in the manuscript. Permission to republish these items must be obtained by the corresponding author from a person or institution holding the copyright, usually the publisher.

Authors are requested to send all drawings used in the article in additional files. Create a separate file for each image. Images should be submitted in a bitmap format (.jpeg) or/and in a vector format (.eps, .pdf or .cdr). Each file must be saved according to the number in the original article, e.g.: FIG1.JPG, FIG2.EPS, or FIG3.PDF. Bitmap illustrations must be “flattened”, which means no additional layers, for example, covering old descriptions.

Photographs, colour, and greyscale figures should be at least at a resolution of 400 dpi.

All colour figures should be generated in the RGB or CMYK colour space, while greyscale images in the greyscale colour space.

When preparing your figures/graphics etc., we suggest the use of the Arial 8 point font for axis numbers and Arial 9 point font for axis names. Figures/graphics etc. can be prepared in one of two proposed ways - see Template AEE.

Tables are numbered with Arabic numerals. Use 9 point Times New Roman for the title of the table and 9 point Times New Roman for the filling of the table (9 in the case of symbols with subscripts).

AEE journal allows an author to publish color figures in e-version at no charge, and automatically convert them to grayscale for print versions. Authors wishing to use the facility of color printing should consult the editors.

Conclusions:

A conclusion might elaborate on the importance of the work or suggest applications and extensions. Although a conclusion may review the main points of the manuscript, do not replicate the abstract as the conclusion.

References:

References in text must be numbered consecutively by Arabic numerals placed in square brackets. Please make sure that you use full names of journals i.e. Archives of Electrical Engineering. Please ensure that all references in the Reference list are cited in the text and vice versa.

Please provide name(s) and initials of author(s), the title of the manuscript, editors (if any), the title of the journal or book, a volume number, the page range, and finally the year of publication in brackets.

You can use the rules presented on the site: IEEE standard.

Examples of the ways in which references should be cited are given below:

Journal manuscript

[1] Author1 A., Author2 A., Title of paper, Title of periodical, vol. x, no. x, pp. xxx-xxx (YEAR).

example

[1] Steentjes S., von Pfingsten G., Hombitzer M., Hameyer K., Iron-loss model with consideration of minor loops applied to FE-simulations of electrical machines, IEEE Transactions on Magnetics. vol. 49, no. 7, pp. 3945-3948 (2013).

[2] Idziak P., Computer Investigation of Diagnostic Signals in Dynamic Torque of Damaged Induction Motor, Electrical Review (in Polish), to be published.

[3] Cardwell W., Finite element analysis of transient electromagnetic-thermal phenomena in a squirrel cage motor, submitted for publication in IEEE Transactions on Magnetics.

Conference manuscript

[4] Author A., Title of conference paper, Unabbreviated Name of Conf., City of Conf., Country of Conf., pp. xxx-xxx (YEAR).

example

[4] Popescu M., Staton D.A., Thermal aspects in power traction motors with permanent magnets, Proceedings of XXIII Symposium Electromagnetic Phenomena in Nonlinear Circuits, Pilsen, Czech Republic, pp. 35-36 (2016).

Book, book chapter and manual

[5] Author1 A., Author2 A.B., Title of book, Name of the publisher (YEAR).

example

[5] Zienkiewicz O., Taylor R.L., Finite Element method, McGraw-Hill Book Company (2000).

Patent

[6] Author1 A., Author2 A., Title of patent, European Patent, EP xxx xxx (YEAR).

example

[6] Piech Z., Szelag W., Elevator brake with magneto-rheological fluid, European Patent, EP 2 197 774 B1 (2011).

Thesis

[7] Author A., Title of thesis, PhD Thesis, Department, University, City of Univ. (YEAR).

example

[7] Driesen J., Coupled electromagnetic-thermal problems in electrical energy transducers, PhD Thesis, Faculty of Applied Science, K.U. Leuven, Leuven (2000).

For on electronic forms

[8] Author A., Title of article, in Title of Conference, record as it appears on the copyright page], © [applicable copyright holder of the Conference Record] (copyright year), doi: [DOI number].

example

[8] Kubo M., Yamamoto Y., Kondo T., Rajashekara K., Zhu B., Zero-sequence current suppression for open-end winding induction motor drive with resonant controller,in IEEE Applied Power Electronics Conference and Exposition (APEC), © APEC (2016), doi: 10.1109/APEC.2016.7468259

Website

[9] http://www.aee.put.poznan.pl, accessed April 2010.

Proofs:

Authors will receive proofs for correction, which should be returned promptly. All joint contributions must indicate the name and address of the authors to whom proofs should be sent.

Fees for printing the papers in Archives of Electrical Engineering:

AEE is published in Open Access, which means that all articles are available on the internet to all users immediately upon publication free of charge for the readers. Authors will be asked to a declaration that they are ready to cover the costs of printing their article.

The publication cost in the AEE journal is estimated at 2 000 PLN, (approx. €500 Euro) up to 20 pages of the journal format and mandatory over-length charges of 120PLN (approx. 40EUR) per page. The publication cost does not include bank transfer costs.

Abstracting & Indexing:

Archives of Electrical Engineering is covered by the following services:

  • Arianta
  • Baidu Scholar
  • BazTech
  • Celdes
  • CNKI Scholar (China National Knowledge Infrastucture)
  • CNPIEC
  • DOAJ
  • EBSCO - TOC Premie
  • EBSCO (relevant databases)
  • EBSCO Discovery Service
  • Elsevier - Compendex
  • Elsevier - Engineering Village
  • Elsevier - SCOPUS
  • Genamics JournalSeek
  • Google Scholar
  • ICI Journals Master List
  • Inspec
  • J-Gate
  • Naviga (Softweco)
  • POL-Index
  • Primo Central (ExLibris)
  • ProQuest - Advanced Technologies Database with Aerospace
  • ProQuest - Electronics and Communications Abstracts
  • ProQuest - Engineering Journals
  • ProQuest - High Tech Research Database
  • ProQuest - Illustrata: Technology
  • ProQuest - SciTech Journals
  • ProQuest - Technology Journals
  • ProQuest - Technology Research Database
  • SCImago (SJR)
  • Summon (Serials Solutions/ProQuest)
  • TDOne (TDNet)
  • TEMA Technik und Management
  • Thomson Reuters - Emerging Sources Citation Index
  • Ulrich's Periodicals Directory/ulrichsweb
  • WorldCat (OCLC)

Preparation of manuscript for Archives of Electrical Engineering (AEE)

AEE License to publish

This page uses 'cookies'. Learn more