The implementation of micro scale combined heat and power systems is one of the ways to improve the energy security of consumers. In fact, there are many available large and medium scale cogeneration units, which operate according to the Rankine Cycle. Due to European Union demands in the field of using renewable energy sources and increasing energy efficiency result in the importance of additionally developing systems dedicated for use in residential buildings, farms, schools and other facilities. This paper shows the concept of introducing thermoelectric generators into typical wood stoves: steel plate wood stoves and accumulative wood stoves. Electricity generated in thermoelectric generators (there were studies on both three market available units and a prototypical unit developed by the authors) may be firstly consumed by the system (to power controller, actuators, fans, pumps, etc.). Additional power (if available) may be stored in batteries and then used to power home appliances (light, small electronics and others). It should be noted that commercially available thermoelectric generators are not matched for domestic heating devices – the main problems are connected with an insufficient heat flux transmitted from the stove to the hot side of the generator (caused e.g. by the non -homogeneous temperature distribution of the surface and bad contact between the stove and the generator) and inefficient cooling. To ensure the high efficiency of micro cogeneration systems, developing a dedicated construction both of the generator and the heat source is necessary.
The paper presents the method for multicriteria design of a synchronous generator voltage regulator. The results of the voltage regulator polyoptimisation are compromise sets for a classic controller of type PI and fuzzy logic controller of type Takagi-Sugeno-Kang. A genetic algorithm is used to solve the polyoptimisation problem.
The paper discusses in detail the construction of the Core Less Axial Flux Permanent Magnet generator simulation model. The model has been prepared in such a way that full compatibility with the elements of the SimPowerSystem library of the Matlab/Simulink package is preserved, which allows easy use of the presented simulation model for testing the work of the generator as part of a larger system. The parameters used in the model come from the MES 3D calculations performed in the Ansys/Maxwell software, for a machine prototype with a rated power of 2.8 kW, which was then used to experimentally verify the correct operation of the presented model of machine.
The process of synchronization of synchronous generators and power electronic converters with the power grid may take on quite different forms. This is due to their specific principles of operation and essential differences in energy conversion process. However, since synchronous generators and power converter often operate in the same utility network, coherent rules should be defined for them. Therefore, this paper aims at a formulation of the uniform and consistent interpretation of synchronization with the power grid for both types of aforementioned units. The author starts from the classic interpretation of synchronization for synchronous generators and power electronic converters, considered as micro-generators, specifies their mathematical and numerical models and then performs simulation tests. Selected synchronization algorithms are described in detail. Simulation tests are used for analysis of the elaboration of outcomes. The results of simulation tests are handled to formulate a uniform interpretation of synchronization for the micro-generation systems considered. Based on the results obtained, appropriate parallels are built between the two systems being compared. It is shown that the synchronization processes are identical regardless of the micro-generation unit considered. Nonetheless, they differ significantly due to their properties in transient states. Inverter systems have higher dynamics but their disadvantage lies in the relatively high sensitivity to disturbances and the complex selection process of the synchronization algorithm.
The purpose of the paper is the investigation of possibility of utilization of a single-phase induction machine, designed and normally operating as a single-phase capacitor induction motor, as a self-excited single-phase induction generator, which can be used to generate electrical energy from non-conventional energy sources. The paper presents dq model of the self-excited single-phase induction generator for dynamic characteristics simulation and steady-state model based on double revolving field theory with two phase symmetrical components – a forward and backward revolving field for performance of the generator under resistive load. Excitation and load characteristics obtained by simulation showed considerable influence of method of capacitor configuration in the load stator winding on terminal voltage, current and output power of the generator under load. An specific construction of the stator windings together with capacitor requirements to obtain nominal output power at desired self-regulating terminal voltage over the operating range will be the aim of further research.
The presented paper concerns the issues of communication networks applied to monitoring and control of reactive power compensator for small hydroelectric plants installed in areas distant from urban agglomerations. Ethernet, CAN, Modbus and GPRS transmission protocols has been used. Industrial programmable controller as a data collector has been used also.
The free piston linear generator is a new range extender concept for the application in a full electric vehicle. The free piston engine driven linear generators can achieve high efficiency at part and full load which is suitable for the range extender application. This paper presents requirements for designing a linear generator deduced from a basic analysis of a free piston linear generator.
The paper presents the advanced control system of the wind energy conversion with a variable speed wind turbine. The considered system consists of a wind turbine with the permanent magnet synchronous generator (PMSG), machine side converter (MSC), grid side converter (GSC) and control circuits. The mathematical models of a wind turbine system, the PMSG generator and converters have been described. The control algorithms of the converter systems based on the methods of vector control have been applied. In the advanced control system of the machine side converter the optimal MPPT control method has been used. Additionally the pitch control scheme is included in order to achieve the limitation of maximum power and to prevent mechanical damage of the wind turbine. In the control system of the grid side converter the control of active and reactive power has been applied with the application of Voltage Oriented Control (VOC). The performance of the considered wind energy system has been studied by digital simulation. The results of simulation studies confirmed the good effectiveness of the considered wind turbine system and very good performance of the proposed methods of vector control and control systems.
A steam generator in a nuclear power plant with a light water reactor is a heat exchanger, in which the heat is being transferred from the primary to the secondary loop (it links the primary and secondary loops). When the power plant is running, the inlet parameters (temperatures and mass flow rates) on both sides of the steam generator can change. It is important to know how the changes of these parameters affect the steam generator performance. The complexity of the processes taking place in the steam generator makes it difficult to create a simulator reflecting its performance under changed conditions. In order to simplify the task, the steam generator was considered as a ‘black box’ with the aim of examining how the changes of the inlet parameters affect the changes of the outlet ones. On the basis of the system (steam generator) response, a simple mathematical model of the steam generator under variable load conditions was proposed. In the proposed model, there are two dimensionless parameters and three constant coefficients. A linear relation between these dimensionless parameters was obtained. The correctness of the model was verified against the data obtained with a steam generator simulator for European Pressured Reactor and AP-600 reactors. A good agreement between the proposed model and the simulator data was achieved.
This paper provides some information about thermoelectric technology. Some new materials with improved figures of merit are presented. These materials in Peltier modules make it possible to generate electric current thanks to a temperature difference. The paper indicates possible applications of thermoelectric modules as interesting tools for using various waste heat sources. Some zero-dimensional equations describing the conditions of electric power generation are given. Also, operating parameters of Peltier modules, such as voltage and electric current, are analyzed. The paper shows chosen characteristics of power generation parameters. Then, an experimental stand for ongoing research and experimental measurements are described. The authors consider the resistance of a receiver placed in the electric circuit with thermoelectric elements. Finally, both the analysis of experimental results and conclusions drawn from theoretical findings are presented. Voltage generation of about 1.5 to 2.5 V for the temperature difference from 65 to 85 K was observed when a bismuth telluride thermoelectric couple (traditionally used in cooling technology) was used.
The paper presents a multi-phase doubly fed induction machine operating as a DC voltage generator. The machine consists of a six-phase stator circuit and a three-phase rotor circuit. Two three-phase six-pulse diode rectifiers are connected to each three-phase machine section on the stator side and in parallel to the common DC circuit feeding the isolated load. The same DC bus is also common for the rotor side power electronics converter responsible for machine control. Two methods – direct torque control DTC and field oriented control FOC – were implemented for machine control and compared by means of simulation tests. Field oriented control was implemented in the laboratory test bench.
This article presents methods and algorithms for the computation of isogenies of degree ℓn. Some of these methods are obtained using recurrence equations and generating functions. A standard multiplication based algorithm for computation of isogeny of degree ℓn has time complexity equal to O(n2 M (n log n)), where M(N) denotes the cost of integers of size N multiplication. The memory complexity of this algorithm is equal to O (n log (n log (n))). In this article are presented algorithms for:
where optimality in this context means that, for the given parameters, no other strategy exists that requires fewer operations for computation of isogeny.
Also this article presents a method using generating functions for obtaining the solutions of sequences (um) and (cm) where cm denotes the cost of computations of isogeny of degree ℓum for given costs p; q of ℓ-isogeny computation and ℓ-isogeny evaluation. These solutions are also used in the construction of the algorithms presented in this article.