Abstract

The article presents the influence of the parameters of the high voltage direct current (HVDC) generator with a multiplier, such as: leakage inductance of the high voltage (HV) transformer, capacitance, and the number of multiplier stages on the value of the output voltage, voltage ripple, power and frequency of the supply voltage as a function of the output current. The presented characteristics were obtained under the synchronization conditions of the inverter output voltage and current that powers the multiplier. The presented results will be useful when designing HVDC generators with Cockcroft-Walton multipliers.
Go to article

Authors and Affiliations

Jan Mućko
1
ORCID: ORCID

  1. Faculty of Telecommunications, Computer Science and Electrical Engineering Bydgoszcz University of Science and Technology Al. prof. S. Kaliskiego 7, 85-796 Bydgoszcz, Poland
Download PDF Download RIS Download Bibtex

Abstract

The article presents the Power Hardware in the Loop (PHIL) approach for an autonomous power system analysis based on the synchronous generator model incorporating magnetic saturation effects. The model was prepared in the MATLAB/Simulink environment and then compiled into the C language for the PHIL platform implementation. The 150 kVA bidirectional DC/AC commercial-grade converter was used to emulate the synchronous generator. It was controlled by the real-time simulation control unit with the prepared synchronous generator model incorporating magnetic saturation effects. The proposed approach was validated on the 125 kVA synchronous generator connected to the active and reactive loads of different values for the steady-state and the transient-state performance studies.
Go to article

Authors and Affiliations

Filip Kutt
1
ORCID: ORCID
Łukasz Sienkiewicz
1
ORCID: ORCID
Szymon Racewicz
2
ORCID: ORCID
Michał Michna
1
ORCID: ORCID
Roland Ryndzionek
1
ORCID: ORCID

  1. Gdansk University of Technology, Faculty of Electrical and Control Engineering ul. Gabriela Narutowicza 11/12, 80-233 Gdansk, Poland
  2. University of Warmia and Mazury in Olsztyn, Faculty of Technical Science ul. Oczapowskiego 11, 10-710 Olsztyn, Poland
Download PDF Download RIS Download Bibtex

Abstract

The influence of the capacitor configuration in the pulse supply system for rail accelerators on its efficiency was investigated in the paper. Two different configurations were compared: the first with a parallel connection of capacitors and the second with a parallel-series connection. In both cases, the same number of capacitors was assumed. All other parameters of the device were kept constant, i.e. mass and dimensions of the armature, rail length and stator geometry. A field-circuit model was used to analyse numerically the transients for different capacitor configurations and voltage values. The model was verified experimentally.
Go to article

Authors and Affiliations

Paweł Piekielny
1
ORCID: ORCID
Andrzej Waindoko
1
ORCID: ORCID
Paweł Mamala
1
ORCID: ORCID

  1. Department Of Electrical Engineering And Mechatronics, Opole University Of Technology Prószkowska 76 Str., 45-758 Opole, Poland
Download PDF Download RIS Download Bibtex

Abstract

In recent years, the high frequency oscillation (HFO) accidents caused by long link delay in modular multilevel converter-based high-voltage direct current (MMC-HVDC) transmission projects have posed new challenges to the safety and stability of power system operation. This paper adopts delay stability margin to measure the high frequency stability of the MMC-HVDC system and derives the state space model of the MMC-HVDC time-delay system considering the link delay. The Lyapunov direct method is extended to the stability analysis of the MMC-HVDC time-delay system and the delay stability margin of the system is solved based on the linear matrix inequality (LMI). Then the influence of the controller parameters on the delay stability margin of the MMC-HVDC system is analyzed. Based on improved Smith predictive compensation control, an HFO suppression strategy of the MMC-HVDC system is proposed to improve the high frequency stability of the system by equivalently reducing and eliminating the total link delay. The effectiveness of the Lyapunov direct method for solving the delay stability margin of the MMC-HVDC system and the superiority of the proposed HFO suppression strategy are verified by the time-domain simulation in PSCAD/EMTDC. The research provides a novel viewpoint for the study of the HFO and suppression strategy of the MMC-HVDC system.
Go to article

Authors and Affiliations

Fang Zhang
1
ORCID: ORCID
Xiugong Liang
1
Wenpeng Yao
1

  1. School of Electrical and Information Engineering, Tianjin University 92 Weijin RoadNankai District, Tianjin, China
Download PDF Download RIS Download Bibtex

Abstract

Increasing numbers of devices of various types are now connected to power lines. Their nonlinear nature harms the operation of the lines, as the line voltage is distorted from a sine wave, which causes disturbances in the operation of other loads. This study proposes a method of active parallel compensation that can be realised using a power supply. The proposed device is a dual-function system: it supplies the load connected to its DC link, and operates as a parallel active filter. This kind of device, with a relatively low value of the rated output power, could be implemented in electrical systems to provide distributed compensation. The second novel aspect of this work is the use of a tunable inductive filter, which is included at the input of the power electronics controlled current source and forms a main part of the power supply. The use of this tunable inductive filter increases the frequency response of the current source, while at the same time, in the quasi-steady state of power supply operation, the pulse modulation component of the input current source remains at a minimum level. This paper discusses the structure of an electrical system with the proposed power supply and the rules of operation for the system, and presents test results based on both a simulation and a laboratory model of the system.
Go to article

Authors and Affiliations

Łukasz Cieplinski
1
Adam Gulczynski
1

  1. Poznan University of Technology, Faculty of Control, Robotics and Electrical Engineering Piotrowo 3A, 60-965 Poznan, Poland
Download PDF Download RIS Download Bibtex

Abstract

In order to deal with the threat of the randomness of large-scale electric vehicle (EV) loads to the safe and economic operation of the distribution network effectively, a forecasting method of EV loads based upon virtual prediction parameter estimation strategy is proposed. Firstly, an in-depth analysis is conducted to thoroughly examine the applicability and target audience of various existing power user load forecasting methods. This initial phase provided a solid foundation for the introduction of the new methods. Secondly, utilizing the Monte Carlo simulation method, a charging load forecasting approach that considers both spatial and temporal distribution is developed. This method effectively captures the diversity of EV charging behaviors by leveraging virtual parameter estimation, integrating insights from historical data into future load predictions, thereby enhancing forecasting accuracy. Finally, to validate the effectiveness of this groundbreaking approach, comprehensive testing was conducted on the MATLAB R2017a simulation platform. This verification phase not only serves to demonstrate the method’s accuracy, but also underscores its practicality and reliability in real-world applications.
Go to article

Authors and Affiliations

Yongxiang Caio
1
Qing Chen
1
Yang Wang
1
Wie Li
2
Jiakuan Ren
1
Yangquan Qu
1

  1. Electric Power Research Institute, Guizhou Power Grid Co., Ltd Guiyang China
  2. Electric Power Research Institute, South Power Grid Co., Ltd Guangzhou, China
Download PDF Download RIS Download Bibtex

Abstract

The advancement of ocean renewable energy through Tidal Stream Turbines (TSTs) necessitates the use of a variety of computer models to properly evaluate TST efficiency. The Doubly Fed Induction Generator (DFIG) is the most widely utilized Wind Turbine (WT) in the expanding global wind sector. Grid-tied wind energy systems often use the DFIG to meet conventional grid needs including power quality enhancement, grid stability, grid synchronization, power regulation, and fault ride-through. This paper demonstrates the design of a novel control scheme for the operation of the DFIG. The suggested control scheme consisted of an Improved Recurrent Fuzzy Neural Network (IRFNN) and Ant Colony Optimization with Genetic Algorithms (GACOs). A global control system is created and executed to monitor the changeover between the two operating modes. The plant enters a variable speed mode when the tidal speed is low enough, where the system is controlled to ensure that the turbo-generator module functions at peak power extraction efficiency for any specific tidal velocity. The findings demonstrate the system’s superior efficiency, with the highest power extraction provided despite variations in tidal stream input.
Go to article

Authors and Affiliations

Ram Krishan Kumarb
1
Jayanti Choudhary
1

  1. Electrical Engineering Department, National Institute of Technology Patna (800005) Bihar, India
Download PDF Download RIS Download Bibtex

Abstract

The article presents the results of research on transverse flux machine (TFM) modifications that led to the development of the cogging machine (PMCM) concept and its further evolutions. The transformation process of the cogging machine from a multi-segment to a single-segment modular design has resulted in a structure identical to the known and commonly used fractional slot concentrated winding permanent magnet synchronous machine (FSCW-PMSM). The paper describes the features gained and lost by the modified machine in various transformation stages. An original method for selecting the number of winding modules is also proposed, depending on the number of coils in a module and the pitch of the pole using a separating tooth between the modules.
Go to article

Authors and Affiliations

Tomasz Lerch
1
ORCID: ORCID

  1. AGH University of Krakow Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering
Download PDF Download RIS Download Bibtex

Abstract

To further enhance the speed regulation range of the hybrid excited machine (HEM), the structure of a magnetic ring is optimized using a combination of the magnetic circuit method (MCM) and numerical analysis method in this paper, and a disc magnetic ring (DMR) is proposed. The magnetic density distribution of the proposed disc magnetic ring hybrid excited machine (DMRHEM) is compared to the radial-axial hybrid excited machine (RAHEM), and the superiority of alleviating a saturation problem in the proposed DMRHEM is determined. To improve the power density, the spoke-type permanent magnet (PM) rotor is applied. The influence of the proposed DMR on the HEM is analyzed, and the field adjustment capability of the proposed DMRHEM is better. Based on this, by combining the bypass principle, the analytical expressions for the relations between the rotor pole-pair number and the motor axial length/stator inner diameter (MAL/SID) as well as flux regulation capability are derived to further explore the superiority of the proposed DMRHEM. The influence mechanism of the rotor pole-pair number and the MAL/SID on the proposed DRMHEM is determined. The optimal MAL/SID and pole-pair number are obtained.
Go to article

Authors and Affiliations

Hongbo Qiu
1
Wenhao Gao
1
Shuaishuai Duan
1

  1. Zhengzhou University of Light Industry China
Download PDF Download RIS Download Bibtex

Abstract

The transportation sector is undergoing a profound transformation, shifting from fossil fuel reliance to electric and hybrid semi-electric alternatives. In response, European countries are implementing novel concepts like electrified highways for trucks and buses, bridging the gap between traditional and electric mobility. This paper centers on the management of electric vehicle (EV) charging infrastructure within industrial zones, crucial nodes for charging networks due to their concentrated economic activity and vehicular movement. The study delves into optimal strategies for deploying charging stations in these zones, considering factors such as station placement, capacity planning, and integration with smart grids to ensure efficient and accessible EV charging. Moreover, the research extends its focus to the integration of vehicle-to-grid (V2G) and grid-to-vehicle (G2V) technologies, illustrating their potential within industrial zones. In our research, we have developed algorithms tailored for the infrastructure of industrial zones, focusing on the integration of storage systems and the charging and discharging dynamics of electric vehicles (EVs). Our case study, supported by numerical simulations, illustrates the outcomes of a 24-hour timeframe, where 126 vehicles were charged, and 134 were discharged. The results provide a comprehensive view of how the grid-maintained balance throughout these operations, ensuring that industrial facilities received the required power to fulfill their operational demands.
Go to article

Authors and Affiliations

Lubomir Bena
1
Rikin Tailor
1
Dusan Medved
1
ORCID: ORCID
Damian Mazur
2
ORCID: ORCID

  1. Faculty of Electrical Engineering and Informatics, Technical University of Kosice Letna 9, 042 00 Kosice, Slovakia
  2. Faculty of Electrical and Computer Engineering, Rzeszow University of Technology al. Powstancow Warszawy 12, 35-959 Rzeszow, Poland
Download PDF Download RIS Download Bibtex

Abstract

This study focuses on the maximum torque current ratio control of synchronous reluctance motors and proposes an optimized control method for the maximum torque current ratio of synchronous reluctance motors based on virtual signal injection. Firstly, the research on the maximum torque current ratio control of synchronous reluctance motors based on the virtual signal injection method is conducted, and the existing virtual unipolar square wave signal injection method is analyzed and studied. Secondly, a non-parametric maximum torque current ratio control strategy based on a synchronous reluctance motor combined with the virtual signal injection method is proposed. This strategy does not involve complex parameter calculations, and the control accuracy is not limited by the accuracy of the parameters in the model. The experimental results showed that under the control of virtual bipolar and unipolar square wave signal injection methods, the load torque was converted from 2 Nm to 6 Nm at t = 2:5 s, and there was a significant change in the current amplitude and waveform of the current vector. Under the control of the bipolar injection method, the current amplitude waveform of the motor was lower than that of the unipolar waveform, and the current was smaller. After the load suddenly changed, it could enter a stable state faster. After the load changed at t = 2:5 s, the phase angle of the current vector was quickly adjusted and stabilized under the control of the bipolar signal. The designed method has a good optimization effect compared to the traditional virtual signal injection method, and can achieve high-performance maximum torque current ratio optimization control on synchronous reluctance motors.
Go to article

Authors and Affiliations

Jinghua Cui
1

  1. The Department of Electrical Engineering, Hebei Chemical and Pharmaceutical CollegeShijiazhuang, 050026, China
Download PDF Download RIS Download Bibtex

Abstract

The equivalent circuit of traditional capacitive voltage transformers often faces the problem of complex data calculation and difficulty in grasping the internal nonlinear characteristics of transformers when constructing broadband models, resulting in poor power accuracy and stability. Therefore, with the help of electromagnetic transient physical models, the admittance sub model and nonlinear model are established by considering the frequency and saturation characteristics of the transformer. Based on the characteristics of capacitive voltage transformers, the model is processed in parallel to obtain a broadband coupling transformer model. The results showed that the error between the simulated current peak amplitude and voltage results of the model and the measured values was less than 2% and 1%, respectively. In the fault results, the harmonic error of the load voltage of the improved transformer was relatively small, far less than the error result of 2.73% of the traditional transformer. The proposed transformer model can better characterize its characteristics and has good transient response ability, providing reference tools and value for the operation and state detection of power systems.
Go to article

Authors and Affiliations

Jie Geng
1
Haiyong Yang
1
Yi Li
1
Xiao Zhang
1
Yihang Wangb
1

  1. Office of Construction and Campus Planning, Tsinghua University Beijing 100084, China
Download PDF Download RIS Download Bibtex

Abstract

This study addresses the issue of diagnosing faults in electric vehicle motors and presents a method utilizing Improved Wavelet Packet Decomposition (IWPD) combined with particle swarm optimization (PSO). Initially, the analysis focuses on common demagnetization faults, inter turn short circuit faults, and eccentricity faults of permanent magnet synchronous motors. The proposed approach involves the application of IWPD for extracting signal feature vectors, incorporating the energy spectrum scale, and extracting the feature vectors of the signal using the energy spectrum scale. Subsequently, a binary particle swarm optimization algorithm is employed to formulate strategies for updating particle velocity and position. Further optimization of the binary particle swarm algorithm using chaos theory and the simulated annealing algorithm results in the development of a motor fault diagnosis model based on the enhanced particle swarm optimization algorithm. The results demonstrate that the chaotic simulated annealing algorithm achieves the highest accuracy and recall rates, at 0.96 and 0.92, respectively. The model exhibits the highest fault accuracy rates on both the test and training sets, exceeding 98.2%, with a minimal loss function of 0.0035. Following extraction of fault signal feature vectors, the optimal fitness reaches 97.4%. In summary, the model constructed in this study demonstrates effective application in detecting faults in electric vehicle motors, holding significant implications for the advancement of the electric vehicle industry.
Go to article

Authors and Affiliations

Wenfang Zheng
1
Tieying Wang
1

  1. Xinxiang Vocational and Technical College, Xinxiang 453000, China
Download PDF Download RIS Download Bibtex

Abstract

To effectively suppress the violent galloping of the catenary additional wires in the strong wind section of high-speed railways, the anti-galloping effectiveness and anti-galloping mechanism of the spacer installed on the catenary additional wires are studied. Firstly, the finite element model of the additional wires of the catenary before and after the installation of the spacer is established. Secondly, the random wind field at the additional wires is simulated by the harmonic synthesis method (WAWS). Finally, the galloping response of the additional wires before and after the installation of the spacer is studied by using the finite element software. The results show that the installation of a single spacer at the midpoint of the span can reduce the vertical amplitude of the AF (Additional Feeder) and the PW (Protection Wire) by more than 39.80% and 41.51%, respectively, and the lateral amplitude decreases by more than 16.55% and 38.30%, respectively. The tension of the AF is greatly reduced, while the tension of the PW is slightly increased, so that the galloping of the AF and the PW tends to be synchronized. With the increase in the number of spacers installed, the anti-galloping effect continues to increase. At the same time, the anti-galloping mechanism of the spacer rod to suppress the vibration of the additional wires through the traction effect is clarified, and the effectiveness of the spacer rod in the anti-galloping of the additional wires of the catenary is proved.
Go to article

Authors and Affiliations

Youpeng Zhang
1
ORCID: ORCID
Yahui Zhang
1
Shanpeng Zhao
1
Qiang Feng
2
Xiaotong Yao
1
Ni Yang
1

  1. School of Automatic and Electrical Engineering, Lanzhou Jiaotong University China
  2. State Grid Ningxia Electric Power Company China
Download PDF Download RIS Download Bibtex

Abstract

Studying the impact of renewable energy sources planned to be connected to the grid, requires the preparation of expert opinions. The task of this opinion is to verify that there are possibilities enabling the connection of the considered source to the network. Each opinion is required to take into account other facilities and those sources which were previously connected to the grid or connection agreement were signed with them. The need to take into account such a large number of sources contributes to potential thermal overloads of high-voltage lines. Sometimes these overloads are insignificant, but in certain situations it turns out that their occurrence may be a reason for refusing to sign connection agreements for new sources. According to network operators, their presence may constitute a threat to the operational security of the grid. The article presents the use of the method of tracking active power flows and the DC method of determining power flows to estimate the impact of these sources on thermal overloading of lines. Using of the IEEE-118 test network, selected nodes were analysed where connecting sources might significantly worsen overloads previously observed or would cause new overloads. The proposed approach will enable potential investors to make proper decisions regarding selection of source connection points. Combining the results obtained by both methods at the same time will allow for the indication of appropriate connection nodes for sources from the point of view of minimising the number of overloaded lines and prospective costs of their uprating.
Go to article

Authors and Affiliations

Paweł Pijarski
1
ORCID: ORCID
Candra Saigustia
1
ORCID: ORCID
Piotr Kacejko
1
ORCID: ORCID
Lubomir Bena
2
Adrian Belowski
1
ORCID: ORCID

  1. Department of Power Engineering, Lublin University of Technology Nadbystrzycka 38A str., 20-618 Lublin, Poland
  2. Department of Electric Power Engineering, Technical University of Kosice Letna 9 str., 042 00 Kosice, Slovakia
Download PDF Download RIS Download Bibtex

Abstract

Dual active full-bridge (DAB) DC–DC converters are widely used in DC microgrids and various fields of power electronics. It has the advantages of high-power density, easy to implement soft switching and bi-directional power transfer capability. Conventional linear controllers have difficulty in meeting the increasing demands for speed and robustness. In this paper, a control strategy based on the Brayton–Moser theory of power shaping is proposed to improve the control strategy of DAB DC–DC converters. The DAB DC–DC converter is modelled and the controller is designed based on the Brayton–Moser power-shaping theory. A simulation of the DAB DC–DC converter is constructed and a comparative analysis is carried out for three control strategies of PI control, passive control and power-shaping Brayton–Moser control under different operating conditions.
Go to article

Authors and Affiliations

Yajing Zhang
1
ORCID: ORCID
Hao Ma
1
Xiuteng Wang
2
Tiancong Shao
2

  1. School of Automation, Beijing Information Science and Technology University No. 12 Qinghe Xiaoying East Road, Haidian District, Beijing, China
  2. Branch of Resource and Environment, China National Institute of Standardization No. 4 Zhi Chun Road, Haidian District, Beijing, China

Instructions for authors

ARCHIVES OF ELECTRICAL ENGINEERING (AEE) (previously Archiwum Elektrotechniki), quarterly journal of the Polish Academy of Sciences is OpenAccess, publishing original scientific articles and short communiques from all branches of Electrical Power Engineering exclusively in English. The main fields of interest are related to the theory & engineering of the components of an electrical power system: switching devices, arresters, reactors, conductors, etc. together with basic questions of their insulation, ampacity, switching capability etc.; electrical machines and transformers; modelling & calculation of circuits; electrical & magnetic fields problems; electromagnetic compatibility; control problems; power electronics; electrical power engineering; nondestructive testing & nondestructive evaluation.

Manuscript submission:

All manuscripts should be submitted electronically on Editorial System.

Submission of paper to the Archives of Electrical Engineering is understood to imply that the article is original, unpublished and is not being considered for publication elsewhere. All articles will be reviewed. Since 2013, Authors wishing to use the facility of colour printing should consult the editors.

Template:

Microsoft Word is recommended as a standard word processor to prepare the paper to the AEE journal. If you use the LaTex format, please transfer your document to Microsoft Word and then use Template AEE.

While editing your paper, make sure that all the mathematical characters (symbols, identifiers, variables, vectors, axis marks, etc.) have the required shape, thickness, and slant kept throughout the whole article. The same appearance of a given mathematic character must be retained regardless of its place (text, equations, tables or figures).

The articles that don’t conform to the above will not be processed and published.

The reviewing process:

Each paper submitted for publication in Archives of Electrical Engineering is subjected to the following review procedure:

a) the paper is reviewed by the editor in chief or guest editor for general suitability for publication in AEE

b) if it is judged suitable two reviewers are selected and a double blind peer review process takes place

c) based on the recommendations of the reviewers, the editor then decides whether the paper should be accepted in its present form, revised or rejected

d) the author(s) is(are) informed by e-mail on the results of the reviewing procedure.

The papers are published on average within 3 months after acceptance.

Requirements for preparation of manuscripts:

The manuscript submitted for publication should have no less than 12 pages and no more than 16 pages. In the case of the manuscript longer than 16 pages, please contact the AEE Editorial Board before submitting your paper. The manuscripts, written in UK English, should be typed using Template AEE according to the following instructions and should include: a title page with the title of a manuscript, a short title; abstract; key words, text; list of references. A DOI number as well as received and revised data will be completed by Editor. When you open Template.doc, select "Print Layout" from the "View" menu in the menu bar (View > Print Layout). Then type over sections of Template.doc or cut and paste from another document and then use markup styles (Home > Styles). For example, the style at this point in the document is "main text").

All papers submitted for publication are assessed on the basis of the mutual anonymity rule as to the names of reviewers and authors. Authors' names and affiliations should not appear in the attached text/tables/figures.

If English is not your first language, ask an English-speaking colleague to proofread your manuscript. The manuscripts that fail to meet basic standards of literacy are likely to be immediately declined or after the language assessment, sent to the authors for linguistic improvement.

The manuscripts are published on average within 3 months after their acceptance.

Do not change the font sizes or line spacing to squeeze more text into a limited number of pages. Leave some open space around your figures.

The AEE journal publishes an ORCID for all authors. You will need a registered ORCID in order to submit your paper for peer review. ORCID registration is free and only takes a minute. Please note that ORCIDs will be added in the course of the author's proofreads.

Text:

The pages must be numbered consecutively. Articles should be divided into numbered sections, and if necessary subsections, preferably: Introduction, Material, Methods, Results, Conclusion and References. Any special characters (e.g. Greek, script, etc.) should be named in the margin where the character first occurs in the text. Names of species are to be accentuated with wavy underlining (italics). Equations should be numbered serially (1), (2), ... on the right side of the page. Footnotes should be avoided, if required, they should be used only for brief notes which do not fit well into the text. Figures and tables have to be included into the text. If table is typed on a separate page its position in the text should be marked. Abbreviations should be explained when they first appear in the text.

Math:

Please use the MathML editor as well as MathType editor to build an equation in your manuscript.

Equations:

Equations should be typed within the text, centred, and should be numbered consecutively throughout the text. Their numbers should be typed in parentheses, flush right. Equations should be referred to in text, e.g. (1), except at the beginning of a sentence: "Equation (1) is ...". All symbols appearing in equations have to be defined in the text, before or just after the equation.

If the symbols are written in Times New Roman use italic fonts. Symbols of vectors and matrices should be written in bold fonts. Do not italicize Greek fonts and mathematical symbols like e.g.: the derivative symbol d, max, min, etc. The indices of symbols that are indices themselves should be written in a clear manner.

Note that the equation is centered using a center tab stop. Please keep the same font in the formulas and text.

Unit Symbols, Abbreviations:

Define abbreviations and acronyms the first time they are used in the text, even after they have been defined in the abstract. Abbreviations such as IEEE, SI, MKS, CGS, sc, dc, and rms do not have to be defined. Do not use abbreviations in the title or heads unless they are unavoidable.

Si units are recommended for use in formulas, drawings and tables., for example the SI unit for magnetic field strength H is A/m. Apply the center dot to separate compound units.

Do not mix complete spellings and abbreviations of units: "Wb/m2" or "webers per square meter," not "webers/m2." Spell units when they appear in text: "...a few henries…", not "...a few H…".

Use a zero before decimal points: "0.25," not ".25." Use "cm3," not "cc."

Unit Symbols, SI Prefixes as well as Abbreviations should be writing in accordance with the IEEE standard

Tables, figures (illustrations) and captions:

The illustrations (line diagrams and photographs) should be suitable for direct reproduction. The lettering as well the details should have proportional dimensions to maintain their legibility after the usual reduction. All illustrations should be numbered consecutively (Fig. X). Tables are numbered with Arabic numerals.

All figures, figure captions, and tables in the text must be inserted into the correct places.

Figures, photos, tables or other parts of a manuscript that have previously appeared in another publication or are not the property of the authors must be properly acknowledged in the manuscript. Permission to republish these items must be obtained by the corresponding author from a person or institution holding the copyright, usually the publisher.

Authors are requested to send all drawings used in the article in additional files. Create a separate file for each image. Images should be submitted in a bitmap format (.jpeg) or/and in a vector format (.eps, .pdf or .cdr). Each file must be saved according to the number in the original article, e.g.: FIG1.JPG, FIG2.EPS, or FIG3.PDF. Bitmap illustrations must be “flattened”, which means no additional layers, for example, covering old descriptions.

Photographs, colour, and greyscale figures should be at least at a resolution of 400 dpi.

All colour figures should be generated in the RGB or CMYK colour space, while greyscale images in the greyscale colour space.

When preparing your figures/graphics etc., we suggest the use of the Arial 8 point font for axis numbers and Arial 9 point font for axis names. Figures/graphics etc. can be prepared in one of two proposed ways - see Template AEE.

Tables are numbered with Arabic numerals. Use 9 point Times New Roman for the title of the table and 9 point Times New Roman for the filling of the table (9 in the case of symbols with subscripts).

AEE journal allows an author to publish color figures in e-version at no charge, and automatically convert them to grayscale for print versions. Authors wishing to use the facility of color printing should consult the editors.

Conclusions:

A conclusion might elaborate on the importance of the work or suggest applications and extensions. Although a conclusion may review the main points of the manuscript, do not replicate the abstract as the conclusion.

References:

References in text must be numbered consecutively by Arabic numerals placed in square brackets. Please make sure that you use full names of journals i.e. Archives of Electrical Engineering. Please ensure that all references in the Reference list are cited in the text and vice versa.

Please provide name(s) and initials of author(s), the title of the manuscript, editors (if any), the title of the journal or book, a volume number, the page range, and finally the year of publication in brackets.

You can use the rules presented on the site: IEEE standard.

Examples of the ways in which references should be cited are given below:

Journal manuscript

[1] Author1 A., Author2 A., Title of paper, Title of periodical, vol. x, no. x, pp. xxx-xxx (YEAR).

example

[1] Steentjes S., von Pfingsten G., Hombitzer M., Hameyer K., Iron-loss model with consideration of minor loops applied to FE-simulations of electrical machines, IEEE Transactions on Magnetics. vol. 49, no. 7, pp. 3945-3948 (2013).

[2] Idziak P., Computer Investigation of Diagnostic Signals in Dynamic Torque of Damaged Induction Motor, Electrical Review (in Polish), to be published.

[3] Cardwell W., Finite element analysis of transient electromagnetic-thermal phenomena in a squirrel cage motor, submitted for publication in IEEE Transactions on Magnetics.

Conference manuscript

[4] Author A., Title of conference paper, Unabbreviated Name of Conf., City of Conf., Country of Conf., pp. xxx-xxx (YEAR).

example

[4] Popescu M., Staton D.A., Thermal aspects in power traction motors with permanent magnets, Proceedings of XXIII Symposium Electromagnetic Phenomena in Nonlinear Circuits, Pilsen, Czech Republic, pp. 35-36 (2016).

Book, book chapter and manual

[5] Author1 A., Author2 A.B., Title of book, Name of the publisher (YEAR).

example

[5] Zienkiewicz O., Taylor R.L., Finite Element method, McGraw-Hill Book Company (2000).

Patent

[6] Author1 A., Author2 A., Title of patent, European Patent, EP xxx xxx (YEAR).

example

[6] Piech Z., Szelag W., Elevator brake with magneto-rheological fluid, European Patent, EP 2 197 774 B1 (2011).

Thesis

[7] Author A., Title of thesis, PhD Thesis, Department, University, City of Univ. (YEAR).

example

[7] Driesen J., Coupled electromagnetic-thermal problems in electrical energy transducers, PhD Thesis, Faculty of Applied Science, K.U. Leuven, Leuven (2000).

For on electronic forms

[8] Author A., Title of article, in Title of Conference, record as it appears on the copyright page], © [applicable copyright holder of the Conference Record] (copyright year), doi: [DOI number].

example

[8] Kubo M., Yamamoto Y., Kondo T., Rajashekara K., Zhu B., Zero-sequence current suppression for open-end winding induction motor drive with resonant controller,in IEEE Applied Power Electronics Conference and Exposition (APEC), © APEC (2016), doi: 10.1109/APEC.2016.7468259

Website

[9] http://www.aee.put.poznan.pl, accessed April 2010.

Proofs:

Authors will receive proofs for correction, which should be returned promptly. All joint contributions must indicate the name and address of the authors to whom proofs should be sent.

Fees for printing the papers in Archives of Electrical Engineering:

AEE is published in Open Access, which means that all articles are available on the internet to all users immediately upon publication free of charge for the readers. Authors will be asked to a declaration that they are ready to cover the costs of printing their article.

The fee for the publication of an article in the AEE journal is 200 Euro.

Abstracting & Indexing:

Archives of Electrical Engineering is covered by the following services:

  • Arianta
  • Baidu Scholar
  • BazTech
  • Celdes
  • CNKI Scholar (China National Knowledge Infrastucture)
  • CNPIEC
  • DOAJ
  • EBSCO - TOC Premie
  • EBSCO (relevant databases)
  • EBSCO Discovery Service
  • Elsevier - Compendex
  • Elsevier - Engineering Village
  • Elsevier - SCOPUS
  • Genamics JournalSeek
  • Google Scholar
  • ICI Journals Master List
  • Inspec
  • J-Gate
  • Naviga (Softweco)
  • POL-Index
  • Primo Central (ExLibris)
  • ProQuest - Advanced Technologies Database with Aerospace
  • ProQuest - Electronics and Communications Abstracts
  • ProQuest - Engineering Journals
  • ProQuest - High Tech Research Database
  • ProQuest - Illustrata: Technology
  • ProQuest - SciTech Journals
  • ProQuest - Technology Journals
  • ProQuest - Technology Research Database
  • SCImago (SJR)
  • Summon (Serials Solutions/ProQuest)
  • TDOne (TDNet)
  • TEMA Technik und Management
  • Thomson Reuters - Emerging Sources Citation Index
  • Ulrich's Periodicals Directory/ulrichsweb
  • WorldCat (OCLC)

Preparation of manuscript for Archives of Electrical Engineering (AEE)

AEE License to publish

This page uses 'cookies'. Learn more